Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Odontol. clín.-cient ; 8(1): 41-46, jan.-mar. 2009. tab, ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-518021

ABSTRACT

O presente trabalho teve como objetivo comparar a eficácia de materiais utilizados como selantes de fóssulas e fissuras oclusais (Vitremer, Vitrofill LC, Vitroseal Alpha e Flurosshield) em primeiros e segundos pré-molares humanos, bem como avaliar a sua penetração nos sulcos dos mesmos. Foram utilizados 40 dentes, sendo estes divididos em 4 grupos, um para cada material testado. Após o preparo dos elementos com broca 2137F, através da técnica invasiva, os espécimes foram seccionados e desgastados para análise microscópica e registro de imagens através do Sistema de Captura de Imagens da UFPE (Power VCR II). O material obtido após desmineralização teve seus tags medidos através do software Scion Image. Os valores resultantes foram submetidos à análise de variância, sendo realizado o teste estatístico de Tukey. Verificou-se uma grande variação dos somatórios dos comprimentos de tags em micrômetros. Concluiu-se, então, que o selante Fluroshield apresentou maior média de penetração, seguido do Vitroseal Alpha, dos ionômeros Vitremer e Vitrofill LC.


The present work has as objective to compare the effectiveness of materials used as occlusal pit and fictions selants (Vitremer, Vitrofill LC, Vitroseal Alpha and Fluroshield) in first and second premolars human being, as well as evaluating its adaptation and penetration in the grooves of the same ones. Had been used 40 teeth, which had been divided in 4 groups, one for each tested material. After the preparation of the elements with 2137F drill, through the invasive technique, the specimens had been parted and consumed for microscopical analysis and register of images through the System of Capture of Images of UFPE (Power VCR II). The material gotten after desmineralization had its tags measured through software Scion Image. The resultant values had been submitted to the analysis of variance, being carried through the statistical test of Tukey. A great variation of the somatorys of the lengths of tags in micrometers, was verified. It is concluded, therefore, that the sealant Fluroshield presented the greater average of penetration, followed of the Vitroseal Alpha, of the ionomer Vitremer and Vitrofill LC.


Subject(s)
Dental Fissures , Glass Ionomer Cements , Pit and Fissure Sealants
SELECTION OF CITATIONS
SEARCH DETAIL