Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Chinese Journal of Cardiology ; (12): 213-217, 2018.
Article in Chinese | WPRIM | ID: wpr-806206

ABSTRACT

Objective@#To evaluate the results of catheter ablation of ventricular tachycardia (VT) via direct ventricle puncture access in patients without traditional approach.@*Methods@#Two idiopathic left fasicular VT patients with mechanical aortic and mitrial valve repalcement and 1 patient with right ventricular originated VT post mechanical tricuspid valve repalcement from March 2010 to July 2012 in Fuwai hospital were enrolled in this study. For left fasicular VT patients, catheter ablation was performed using transapical left ventricular access via minithoracotomy. For the patient with right ventricular originated VT, catheter ablation was performed via percutaneous right ventricle puncture at xiphoid. Abaltion was guided under EnSite NavX mapping system. The feasibility of VT ablation via direct ventricle puncture access and long-term VT recurrence were investigated.@*Results@#Catheter ablation was successful in all patients, and all clinical VTs were eliminated. The procedure time was 53, 62 and 74 minutes respectively with radiation time 11, 16 and 20 minutes. The ablation time was 130, 170 and 240 seconds individually. No procedure related complication occurred. After a follow-up time of 76, 55 and 82 months respectively, no VT recurrence was found in patients with left fasicular VT. New-onset VT with different morphology with previous VT was recorded in the patient with right ventricular originated VT, subcutaneous implantable defibrillator was implanted finally in this patient.@*Conclusions@#For patients with endocardial origined ventricular arrhythmias which could not be ablated via traditional approaches, direct ventricle puncture access with hybrid techniques provides a new approach foreliminating VTs in these patients.

2.
Chinese Journal of Cardiology ; (12): 204-208, 2017.
Article in Chinese | WPRIM | ID: wpr-808323

ABSTRACT

Objective@#To assess the relationship between serum albumin level and clinical outcome in heart failure (HF) patients receiving cardiac resynchronization therapy (CRT).@*Methods@#In this retrospective cohort study, 357 consecutive chronic heart failure patients receiving CRT between January 2010 and December 2015 were enrolled and divided into two groups based on pre-CRT serum albumin (albumin≥40 g/L, n=244; albumin<40 g/L, n=113). Clinical outcomes were defined as all-cause mortality (including heart transplantation) and rehospitalization due to worsening HF.Baseline characteristics were compared and all-cause mortality (including heart transplantation) and rehospitalization due to worsening heart failure (HF) were analyzed using Kaplan-Meier curves.Prognostic value of albumin level was evaluated in Cox proportional-hazards regression models.@*Results@#Over a median follow-up time of 21 months, 45 patients (12.6%) died, 4 patients (1.1%) underwent heart transplantation and 100 patients (28.0%) were rehospitalized due to worsening HF. HF patients with pre-CRT albumin<40 g/L were related with worse NYHA function class, lower HDL-C level and ACEI/ARB use compared to HF patients with pre-CRT albumin≥40 g/L. Kaplan-Meier analyses evidenced lower survival rate in HF patients (log-rank test: P=0.000 4, χ2=12.60) and higher rehospitalization rate due to worsening HF (log-rank test: P=0.009, χ2=6.82) in HF patients with pre-CRT albumin<40 g/L.Multivariate Cox analyses indicated that serum pre-CRT albumin <40 g/L was an independent risk factor for all-cause mortality (HR=2.019, 95%CI 1.125-3.622, P=0.018) and HF rehospitalization (HR=1.517, 95%CI 1.014-2.270, P=0.043).@*Conclusion@#Pre-CRT serum albumin level is associated with the severity of heart failure in CRT recipients.Patients with lower pre-CRT albumin level face increased risk of all-cause mortality and HF rehospitalization in chronic heart failure patients receiving cardiac resynchronization.

3.
Chinese Circulation Journal ; (12): 761-765, 2017.
Article in Chinese | WPRIM | ID: wpr-614147

ABSTRACT

Objective: To create and validate a scoring system for predicting clinical prognosis in patients with cardiac resynchronization therapy (CRT). Methods: A cohort of 367 consecutive patients received CRT in our hospital from 2010-01 to 2015-12 were enrolled. The endpoint follow-up events were all-cause death including heart transplantation and heart failure re-admission. The patients were randomly categorized into 2 groups: Modeling group, to develop HEAL scoring system,n=300 and Veriifcation group, to validate HEAL model,n=67. HEAL system was established by Cox proportional hazards regression model, discrimination between HEAL and EARRN scoring systems was evaluated by AUC of ROC, HEAL calibration was assessed by Hosmer-Lemeshow test and clinical endpoint evaluation by 2 scoring systems were compared by Kaplan-Meier method. Results: Modeling group analysis indicated that hs-CRP (HR=1.137, 95% CI 1.072-1.205,P10. AUC for risk classification in Modeling group and Verification group were 0.719(95% CI 0.629-0.809) and 0.708 (95% CI 0.539-0.878), HEAL can well distinguish clinical prognosis in patients at different risk levels (log-rank test showed in Modeling groupP<0.001 and in Veriifcation groupP=0.002); Hosmer-Lemeshow test presented good calibration,P=0.952. All 367 patients were respectively evaluated by HEAL and EARRN scoring systems, HEAL had the better discrimination than EARRN as AUC 0.763 (95% CI 0.692-0.833) vs AUC 0.602 (95% CI 0.517-0.687). Conclusion: HEAL scoring system can effectively predict adverse prognosis in CRT patients, it had the better discrimination than EARRN system and was valuable to distinguish high risk patients in clinical practice.

4.
Chinese Circulation Journal ; (12): 646-649, 2017.
Article in Chinese | WPRIM | ID: wpr-617055

ABSTRACT

To explore the safety and efficacy of left atrial appendage (LAA) occlusion under the guidance of local anesthesia and modified transseptal puncture technology by coronary sinus assisted positioning in patients with nonvavular atrial fibrillation (NVAF). Methods: A total of 16 NVAF patients received local anesthesia and percutaneous LAmbre or Amplatzer cardiac plug occluder implantation. There were 12 males and the patients mean age was at (71.0±6.0) years with CHA2DS2-VASc score at (4.1±1.5); all patients had walfarin contradiction or with walfarin related side effect. Transseptal puncture was conducted by coronary sinus catheter as the anatomic location marker. Results: All 16 patients finished transseptal puncture and no relevant complication occurred. 15/16 (93.8%) patients had successful LAA occlusion, 1 patient was abandoned because of LAA anatomic structure variation. The mean operative time was (65.0±23.0) min and the mean X-ray exposure time was (12.0±3.0) min. The mean diameter of occluder was (32.5±6.0)mm. Conclusion: LAA occlusion was safe and effective with local anesthesia and modified transseptal puncture technology by coronary sinus assisted positioning in relevant patients.

5.
Chinese Circulation Journal ; (12): 461-464, 2017.
Article in Chinese | WPRIM | ID: wpr-616020

ABSTRACT

Objective: To analyze the clinical features and outcomes of cardiac resynchronization therapy (CRT) in patients with dilated-phase hypertrophic cardiomyopathy (DHCM). Methods: A total of 16 DHCM patients received CRT in our hospital from 2007-03 to 2016-01 were retrospectively studied to analyze their clinical features and outcomes. Results: There were 12 male and 4 female patients at the mean age of (53.3±13.5) years. Pre-operative QRS duration of ECG was (158.7±32.2) ms, left ventricular ejection fraction (LVEF) was (33.6±6.3) %, the patient with NYHA class I, II, III and IV were 1, 5, 8 and 2 respectively. 13 patients received new CRT device, 3 received upgraded device and 8 (50%) combining atrial fibrillation (AF). The patients were followed-up for (2.56±2.13) years, 5 of them died including 3 of heart failure, 1 of sudden death and 1 of stroke. At 6 months follow-up time, 7 patients had the response to CRT which was defined by the improvement of NYHA class≥1 and the absolute elevation of LVEF≥5%; NYHA class improved from (2.69±0.79) to (2.38±0.89), P=0.02; LVEF increased from (33.6±6.3) % to (40.03±9.83) %, P=0.01. Conclusion: DHCM patients with CRT indication had the higher incidence to suffer from AF, those were more in patients with traditional pacemaker or ICD upgrading. DHCM patients with CRT had the poor general prognosis, while there was still certain proportion of patients had the response to CRT.

6.
Chongqing Medicine ; (36): 3460-3462, 2017.
Article in Chinese | WPRIM | ID: wpr-614953

ABSTRACT

Objective To study the cardiac electrophysiology changes of canine asynchrony ischemic heart failure under left ventricular endocardial pacing.Methods Left bundle branch radiofrequency catheter ablation and left anterior descending coronary artery ligation were used to establish the model of ischemic heart failure in 18 healthy dogs.Eighteen healthy dogs were randomly divided into two groups,9 cases in each group.The experimental group was treated with cardiac resynchronization therapy(CRT) in left ventricular endocardium,and the control group underwent the sham operation.ECG and echocardiography were done at 6 weeks after operation.Results The left ventricular ejection fraction in the experimental group was significantly higher than that in the control group(38.32 ± 6.08 vs.30.62 ±8.96).The asynchronization index in the experimental group was significantly lower than that in the control group(35.99 ±5.25 vs.78.21 ± 7.02),and the difference was statistically significant(P<0.05).QRS(60.58 ± 7.43 vs.68.33 ± 8.01) and QTc(347.09 ± 17.33 vs.367.81 ± 22.02)in the experimental group were significantly shorter than those in the control group(P<0.05);moreover Tp-e(37.03±9.07 vs.45.76±7.11) and ARI(162.33±22.06 vs.187.21±23.87) in the experimental group were significantly lower than those in the control group(P<0.05).Conclusion Left ventricular endocardial pacing can produce preferably electrophysiological effects and achieve the goal of effective cardiac resynchronization therapy.

7.
Chinese Circulation Journal ; (12): 250-253, 2016.
Article in Chinese | WPRIM | ID: wpr-484435

ABSTRACT

Objective: To explore the effects of cardiac resynchronization therapy (CRT) in patients with dispersion of re-polarization and ventricular arrhythmia. Methods: A total of 86 consecutive patents with CRT implantation were enrolled. According to weather absolute value of LVEF increased≥10% from baseline at 6 months after CRT implantation, the patients were divided into 2 groups: Response group and Non-response group,n=43 in each group. Dispersion of re-polarization indexes as QRS duration, QTc interval, TpTe interval and the events of ventricular arrhythmia were compared between 2 groups at different time points after CRT. Results:①In Response group, compared with pre-operation, QRS duration and TpTe interval were shorter at 1 year and within 24h after CRT implantation, allP0.05.②During 1 year after CRT implantation, the incidences of PVCs and PVC runs in Response group were much less than those in Non-response group, for lgPVCs: (1.78 ± 0.77) vs (2.73 ± 0.61), for lgPVC runs: (0.64 ± 0.48) vs (1.98 ± 0.72),P Conclusion: CRT ventricular reverse remodeling may reduce dispersion of re-polarization and the risk of ventricular arrhythmia, therefore improve the prognosis in relevant patients; TpTe interval within 24h after CRT had the predictive value for ventricular arrhythmia.

8.
Chinese Circulation Journal ; (12): 72-75, 2015.
Article in Chinese | WPRIM | ID: wpr-462764

ABSTRACT

Objective:To explore the efifcacy and safety for radiofrequency catheter ablation (RFCA) of left bundle branch guided by left bundle potential (LBP), X-ray image with EnSiteNavX System in canine model. Methods:The RFCA of left bundle branch was conducted in 13 dogs. A mapping catheter was positioned in right atrium to record right-sided His-bundle (R-His) potential, and an ablation catheter via right femoral artery was retrograded to left ventriclefor LBP mapping and ablation. Meanwhile, EnSiteNavX System was used to identify R-His, L-His and LBP at the same time. The potential characteristics in dogs with successful ablation were observed, the PR interval, QRS shape and time limit, AH interval, HV interval, the A/V electro-gram ratio in ablationcatheter at before and after ablation were recorded. The procedural time and X-ray exposure time between LBP with X-ray image method and LBP, X-ray image with EnSiteNavX System method were compared. Results: There were 9/13 dogs received successful left bundle branch ablation, 3 dogs failed and 1 suffered from complete A-V block. At the successful ablation target site, the LBP-V was (17.8 ± 2.6) ms with the range of (13-21) ms, and the A/V electro-gram ratio Conclusion:Under the LBP, X-ray image with EnSiteNavX System guidance method, left bundle branch could be safely and effectively ablated to establish left bundle branch block (LBBB) model in experimental canine.

9.
Chinese Medical Journal ; (24): 4036-4042, 2014.
Article in English | WPRIM | ID: wpr-268427

ABSTRACT

<p><b>BACKGROUND</b>Renal insufficiency (RI) is significantly associated with clinical prognosis in patients with heart failure (HF), but direct evidences on the relation between renal function and clinical outcome in patients receiving cardiac resynchronization therapy (CRT) are limited. The aim of the current study was to systematically evaluate the association of baseline and 6-month renal function with cardiac reverse remodeling and long-term outcome after CRT.</p><p><b>METHODS</b>We retrospectively evaluated 190 consecutive patients who underwent CRT at Fuwai Hospital from January 2008 to April 2013. Renal function tests, echocardiographic measurement, and clinical parameters at baseline and after 6 months of CRT were performed. Primary endpoint events included all-cause mortality, cardiac transplantation, and unplanned hospitalizations for HF.</p><p><b>RESULTS</b>At baseline, compared with normal renal function or mild RI (estimated glomerular filtration rate (eGFR) ≥60 ml×min(-1)×1.73 m(-2)), moderate-to-severe RI (eGFR <60 ml×min(-1)×1.73 m(-2)) exerted a negative influence on cardiac reverse remodeling parameters. At 6-month follow-up, 114 (60.0%) patients were classified as responders and showed significant renal function improvement, whereas renal function deteriorated in non-responders and subsequently 41 (25.6%) patients developed worsening renal function (WRF). During the mean follow-up of (24.3±17.1) months, both patients with baseline eGFR <60 ml×min(-1)×1.73 m(-2) and those with WRF experienced worse event-free survival (P < 0.01, respectively).</p><p><b>CONCLUSIONS</b>This analysis identified that baseline eGFR as well as WRF after CRT were found to be independent determinants of the combined endpoints of all-cause mortality and HF-related hospitalizations in CRT recipients.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiac Resynchronization Therapy , Disease-Free Survival , Heart Failure , Kidney , Kidney Function Tests , ErbB Receptors , Retrospective Studies
10.
Journal of Geriatric Cardiology ; (12): 296-302, 2014.
Article in Chinese | WPRIM | ID: wpr-457948

ABSTRACT

Background The data on the prognostic values of high sensitivity C-reactive protein (hsCRP) levels in patients with advanced symp-tomatic heart failure (HF) receiving cardiac resynchronization therapy (CRT) are scarce. The aim of present study was to investigate the association of serum hsCRP levels with left ventricle reverse remodeling after six months of CRT as well as long-term outcome. Methods A total of 232 CRT patients were included. The assessment of hsCRP values, clinical status and echocardiographic data were performed at baseline and after six months of CRT. Long-term follow-up included all-cause mortality and hospitalizations for HF. Results During the mean follow-up periods of 31.3 ± 31.5 months, elevated hsCRP (>3 mg/L) prior to CRT was associated with a significant 2.39-fold increase (P=0.006) in the risk of death or HF hospitalizations. At 6-month follow-up, patients who responded to CRT showed significant reductions or maintained low in hsCRP levels (–0.5 ± 4.1 mg/L reduction) compared with non-responders (1.7 ± 6.1 mg/L increase, P=0.018). Com-pared with patients in whom 6-month hsCRP levels were reduced or remained low, patients in whom 6-month hsCRP levels were increased or maintained high experienced a significantly higher risk of subsequent death or HF hospitalizations (Log-rank P<0.001). The echocardio-graphic improvement was also better among patients in whom 6-month hsCRP levels were reduced or remained low compared to those in whom 6-month hsCRP levels were raised or maintained high. Conclusions Our findings demonstrated that measurement of baseline and follow-up hsCRP levels may be useful as prognostic markers for timely potential risk stratification and subsequent appropriate treatment strategies in patients with advanced HF undergoing CRT.

11.
Journal of Geriatric Cardiology ; (12): 253-257, 2013.
Article in Chinese | WPRIM | ID: wpr-475339

ABSTRACT

Background Intrathoracic impedance monitoring has emerged as a promising new technique for the detection of impending heart failure (HF). Although false positive episodes have been reported in case reports and clinical trials, the efficacy and false positive rate in real-world practice remain unclear. Objective The aim of this study is to investigate the utility and reliability of the OptiVol alert feature in clinical practice. Methods We continuously recruited patients who underwent implantable cardioverter-defibrillator (ICD) or cardiac re-synchronization therapy with defibrillator (CRT-D) implantation with feature of intrathoracic impedance monitoring system in our center from Sep. 2010 to Oct. 2012. Regular in-office follow-up were required of all patients and the following information was collected at each visit: medical history, device interrogation, N-terminal pro-brain natriuretic peptide (NT-proBNP) measurement and an echocardiogram. Worsening HF was defined as hospitalization or the presentation of signs or symptoms of HF. Results Forty three patients (male:76.7%, mean age:57 ± 15 years, left ventricular ejection fraction (LVEF):33%± 14%) were included in this observational study. Fifty four alert events and 14 adjudicated worsening HF were detected within 288 ±163 days follow-up. Eleven (20.4%) alert episodes were associated with acute cardiac decompensation in 9 patients with a positive predictive value of 78.6%. Forty three audible alerts showed no connection to worsening HF. The unexplained alerts rate was 79.6%and 1.27 per person-year. Thirty seven alarm alerts were detected in patients with EF<45%, among which 9 accompanied with HF, 17 alerts detected in patients with LVEF≥45%and 2 associated with HF. There was no sig-nificant difference between the two groups (9/37 vs. 2/17;P=0.47). Conclusions Patients with normal or nearly normal left ventricular systolic function also exhibited considerable alert events. The OptiVol fluid index predicted worsening cardiac events with a high unex-plained detection rate, and any alert must therefore be analyzed with great caution. Efforts to improve the specificity of this monitoring sys-tem represent a significant aspect of future studies.

SELECTION OF CITATIONS
SEARCH DETAIL