Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Chinese Journal of Radiological Health ; (6): 234-238, 2022.
Article in Chinese | WPRIM | ID: wpr-973487

ABSTRACT

Objective To compare echocardiogram and cardiac magnetic resonance imaging (MRI) for diagnosis of hypertrophic cardiomyopathy. Methods A total of 137 patients suspected of hypertrophic cardiomyopathy were recruited. All patients received three-dimensional echocardiogram followed by cardiac MRI, and the detection rate of hypertrophic cardiomyopathy was compared. Results A total of 96 eligible patients with hypertrophic cardiomyopathy were finally enrolledin this study, including 70 males (72.9%) and 26 females (27.1%), with a mean age of 48.2 ± 10.2 years. There was a significant difference in the detection rate of hypertrophic cardiomyopathy by echocardiogram (93.8%) and by cardiac MRI (100%) (χ2 = 4.30, P = 0.03). Among the 96 subjects, there was no significant difference in the mean value of maximum left ventricular wall thickness measured by echocardiogram and cardiac MRI (22.1 ± 8.9 vs 22.8 ± 9.2 mm; t = 1.23, P = 0.32). There was a significant difference in the mean thickness of the basal anterolateral free wall in the left ventricle (18.2 ± 7.8 vs 13.9 ± 7.1 mm; t = 9.40, P = 0.0007). Conclusion Cardiac MRI scanning is superior to echocardiogram for diagnosis of hypertrophic cardiomyopathy, which may be used as an effective supplement to conventional echocardiogram.

2.
Chinese Journal of Practical Nursing ; (36): 109-112, 2017.
Article in Chinese | WPRIM | ID: wpr-507337

ABSTRACT

Objective To discuss the influence of preoperative family purge care for the quality of life of patients with long type of congenital Hirschsprung′s disease (HD) who had enterocolitis history in neonatal period. Preoperative family purge care, which can shorten the HD postoperative treatment, improve the quality of life. Methods A total of 40 cases of patients with long type of congenital HD who had enterocolitis history in neonatal period received 1-stage radical preoperative by family phone call. Nineteen cases from January 2010 to February 2013 were as normal group and 21 cases from March 2013 to April 2016 were as improved group. Routine family purge nursing care 3-6 months were used in both the groups, while the combined nursing care of expanding anus were used in the improved group in addition. Evaluated the effects of postoperative observation indicates: the first defecation time, length of hospital stay, time needed for expanding anus, patency rate of defecation and not patency rate in 9-12 days, need enema intervention to assist defecate rate after postoperative 1 year, the recurrence of enterocolitis at 1-3 years after operation. Results The first defecation time, length of hospital stay, time needed for expanding anus were (39.15±8.23) h, (7.89±0.82)d, (5.17±0.98) min in normal group, (23.79± 7.54) h, (7.10± 0.29) d, (3.15±0.73) min in improved group, and there were significant differences between two groups (t=6.13, 5.46, 15.54, all P0.05). Conclusions Patient with long type of congenital HD who had enterocolitis history in neonatal period neonatal period,received family enema and expanding anus in 3- 6 months before 1-stage radical preoperative can shorten the postoperative HD treatment, improve the quality of life.

3.
Journal of Southern Medical University ; (12): 1377-1381, 2013.
Article in Chinese | WPRIM | ID: wpr-319408

ABSTRACT

<p><b>OBJECTIVE</b>To explore the appropriate acoustic parameters for augmenting the permeability of tumor cells using microbubble-enhanced ultrasound.</p><p><b>METHODS</b>Ninety intramuscular VX2 tumors grown in New Zealand white rabbits were randomly divided into 4 parts by 4 factors, namely sound intensity, pulse width, insonation time and microbubble dose, each at different levels. Therapeutic ultrasound was delivered directly to the tumor surface during intravenous infusion of microbubbles. The tumor was excised after the treatment and sliced to investigate the change in tumor cell permeability using lanthanum nitrate electron microscopy. The appropriate acoustic parameters of the 4 factors were investigated.</p><p><b>RESULTS</b>Sonoporation induced by microbubble-enhanced ultrasound augmented the permeability of the tumor cells, and the appropriate sound intensity, pulse width, insonation time and microbubble dose were 0.43 W/cm(2), 2.42 ms, 10 min, and 0.50 ml/kg, respectively.</p><p><b>CONCLUSION</b>Sonoporation induced by microbubble-enhanced ultrasound can induce pores in tumor cell membrane, which may potential increase the efficacy of tumor chemotherapy.</p>


Subject(s)
Animals , Rabbits , Acoustics , Cell Line, Tumor , Cell Membrane Permeability , Microbubbles , Neoplasms , Therapeutics , Ultrasonic Therapy , Ultrasonics
4.
Journal of Southern Medical University ; (12): 1519-1522, 2012.
Article in Chinese | WPRIM | ID: wpr-352395

ABSTRACT

<p><b>OBJECTIVE</b>To assess the clinical value of transoral carotid ultrasonography (TOCU) in the detection of the blood flow parameters of the distal extracranial internal carotid artery (ICA) in patients with moyamoya disease.</p><p><b>METHODS</b>Fourteen patients with the diagnosis of moyamoya disease confirmed by digital subtractive angiography (DSA) underwent examination with conventional carotid ultrasonography of the proximal internal carotid artery (ICA). TOCU was performed to observe the distal extracranial ICA and the internal diameter, peak systolic velocity (PSV) and end-diastolic velocity (EDV) were measured.</p><p><b>RESULTS</b>All the patients had unilateral moyamoya disease. Compared with the contralateral ICA, distal extracranial ICA showed a significantly reduced internal diameter, PSV and EDV (P<0.05). No significant differences were found in the internal diameter, PSV or EDV between the distal and proximal ICA on the diseased side. The internal diameter of the bilateral common carotid arteries (CCA) was similar, but the PSV and EDV were significantly lower in the contralateral CCA.</p><p><b>CONCLUSION</b>TOCU can provide information of the blood flow in the distal extracranial ICA to facilitate an accurate diagnosis of moyamoya disease.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Carotid Artery, Internal , Diagnostic Imaging , Hemodynamics , Moyamoya Disease , Diagnostic Imaging , Ultrasonography , Methods
5.
Chinese Journal of Ultrasonography ; (12): 300-304, 2012.
Article in Chinese | WPRIM | ID: wpr-418716

ABSTRACT

Objective To investigate the value of transoral carotid ultrasonography (TOCU) in detecting the change of distal extracranial internal carotid artery(ICA) with stenosis and occlusion in its initial segmen.Methods One hundred and ten patients with stenosis at least 50% or occlusion in the initial segment of ICA diagnosed by high-frequency linear probe were enrolled as case group,while thirty two with healthy carotid arteries as control group.Both of the case and control groups were undergone high-frequency linear probe to examine CCA and the initial segment of ICA,and TOCU to observe their lumen transparency,color Doppler flow display and change of Doppler flow spectrum,even measuring the internal diameter,peak systolic velocity (PSV),end-diastolic velocity(EDV) and PSVICA/PSVCCA ratio,respectively.Digital subtraction angiography (DSA)were performed within two weeks,then compared with ultrasonography.Results 92.7% patients were performed TOCU examination in case group and 93.8% in control group.The internal diameter and PSV of the distal extracranial ICA became gradually smaller from control group to near occlusion group,and there were statistical significance between groups ( P <0.05),however,near occlusion group had no statistical significance compared with occlusion group( P >0.05).There were 80% arteries having thrombus echo in occlusion group,and the others in this group having no thrombus had gloomy colour flow,even got low-velocity artery spectrum.Doppler flow spectrum of distal extracranial ICA showed characteristics of slow wave or single peak in near occlusion group,and spike shape or slow wave in 76.7 % arteries of 70% ~near-occlusion stenosis group,but spike shape in 30.8% arteries of 50%~69% stenosis group,and the others were normal.Conclusions TOCU is useful for detecting the changing regularity of distal extracranial ICA with stenosis or occlusion in its initial segment and has the value of clinical application in association with high-frequency linear probe.

6.
Chinese Journal of Ultrasonography ; (12): 1070-1073, 2011.
Article in Chinese | WPRIM | ID: wpr-423473

ABSTRACT

ObjectiveTo assess the feasibility of evaluation of renal allograft acute rejection in rat withcontrast-enhancedultrasound( CEUS )andtargetedmicrobubbles.MethodsPhospholipid microbubbles targeted to intercellular adhesion molecule -1 (ICAM-1)(MBI) and control microbubbles (MB) were created by conjugating monoclonal antibody against ICAM-1 or isotype control antibody to the lipid capsule via “avidin-biotin” bridging.Ten SD rats with acute renal allograft rejection were injected intravenous of MBI and MB in random order with a 30-min interval.After 3 min of intravenous injection of microbubbles,targeted CEUS imaging was performed in all rats.And then the video intensity (VI) was determined.ResultsIn MBI group,a significant ultrasonic enhancement was observed,but it was not very obvious in MB group.Increment in VI value of transplant kidney in MBI group was great and it amounted to (27.0 ± 7.4)U,however,increment in VI value of in MB group was minor and it was merely (10.2 ± 2.4) U,Difference was evident in transplant kidney between of the two groups (P < 0.05).Conclusions Molecular imaging of ICAM-1 with targeted CEUS can evaluate renal allograft acute rejection effectively.

7.
Chinese Journal of Nephrology ; (12): 735-739, 2011.
Article in Chinese | WPRIM | ID: wpr-419997

ABSTRACT

ObjectiveTo elucidate the association between aquaporins (AQPs) expression in kidney tissue and edema of nephrotic syndrome(NS) patients.MethodsNS patients were divided into edema group (14 cases) and non-edema group (8 cases).Ten patients without NS were used as control group.Expressions of AQP1,AQP2,and AQP4 in renal tissues of 3 groups were detectedbyimmunohistochemistrywithstandardtechniquesandsemi-quantitativeanalysis.Association between AQPs expression and edema was examined.ResultsThe positive index of AQP1 expression in proximal tubules in edema group was 0.0373±0.0110,which was significantly lower as compared to non-edema group (0.0510±0.0120) and control group 0.0574±0.0100),while the difference between non-edema and control groups was not significant.The positive index of AQP1 expression in glomerulus was 0.0106±0.0037 in edema group,which was significantly higher than that in non-edema group(0.0021±0.0013) and control group(0.0020±0.0012),while no significant difference was found between the last two groups.AQP2 mainly localized in the collecting duct system.The positive indexes of AQP2 expression were 0.0498±0.0081,0.0370± 0.0072 and 0.0255±0.0103 in edema group,non-edema group and control group,respectively.The differences were significant among 3 groups.AQP4 expression was not found in the renal cortex and collecting duct system.ConclusionsAQPs expression is different in renal tissues of NS patients.AQP2 may play an important role in the edema of NS patients,and AQP1 may involve in the occurrence of edema.

8.
Chinese Journal of Nephrology ; (12): 235-239, 2008.
Article in Chinese | WPRIM | ID: wpr-383848

ABSTRACT

Objective To describe the circadian profiles of interdialytic blood pressure in maintenance hemodialysis patients and to investigate its related factors. Methods Ambulatory blood pressure monitoring (ABPM)was conducted in forty-four patients on regular hemodialysis during interdialytic days.Three groups were identified with their ambulatory blood pressure:non-hypertension group,controlled hypertension group and uncontrolled hypeaension group.Hemoglobin,creatinine,Kt/V,serum total calcium,serum phosphate,immunoreactive parathyroid hormone(iPTH),interdialytic weight gain and Morisky self-report scale etc.were assessed. Results (1)No significant difference was found in ABPM index ranged from decline in nocturnal systolic and diastolic blood pressure,AASI to dipper percentage in three groups.Nevertheless,24-h average pulse pressure in uncontrolled hypertension group was higher than the other groups[(80.06+13.41)vs(53.00±7.73),(57.85±21.97)mm Hg,all P<0.01].(2)All the three groups showed the blood pressure profile of double-peak and trough.In the uncontrolled hypertension group,however,the nocturnal blood pressure decrease was not notable.(3)Nocturnal systolic blood pressure decline Was negatively correlated to iPTH(r=-0.039,P<0.05).(4)In ten dippers out of all 44 patients,AASI was negatively correlated with nocturnal diastolic blood pressure decline (r=-0.748,P<0.05). Conclusion Nocturnal blood pressure decline is correlated to iPTH and arterial selerosis.

9.
Chinese Journal of Practical Nursing ; (36): 41-42, 2008.
Article in Chinese | WPRIM | ID: wpr-400771

ABSTRACT

Objective To discuss the position nursing for neonates with type three congenital esophageal atresia after operation. Methods We selected 10 patients with type three congenital esophageal atresia from September 2004 to May 2007.The respirator, trachea catheter was removed after operation and the SpO2 was lower than 95% through head mask.Then the SpO2 was compared in different positions of patients,that is face forward,face lateral, face forward with hypsokinesis,face lateral with hypsokinesis. Results All the ten patients survived the operation.The Sp02 in the four positions under oxygen inhalation were (90.30±0.95)%, (89.90±0.74)%, (96.80±1.48)%, (95.90±0.88)%.The former two results were statistically different from the latter two results (P < 0.01). Conclusions The position of face forward with hypsokinesis and face lateral with hypsokinesis facilitated the transition to natural respiration for patients with type three congenital esophageal atresia after remove of respirator and trachea catheter.This could prevent the incidence of complications and the probability of reuse of respirator.

SELECTION OF CITATIONS
SEARCH DETAIL