Chinese Journal of Radiation Oncology ; (6): 145-151, 2023.
Article in Chinese | WPRIM | ID: wpr-993165

ABSTRACT

Objective:To develop the real-time radiotherapy monitoring system of three-dimensional (3D) point cloud by using depth camera and verify its feasibility.Methods:Taking the depth camera coordinate system as the world coordinate system, the conversion relationship between the simulation CT coordinate system and the world coordinate system was obtained from the calibration module. The patient's simulation CT point cloud was transformed into the world coordinate system through the above relationship, and registered with the patient's surface point cloud obtained in real-time manner by the depth camera to calculate the six-dimensional (6D) error, and complete the positioning verification and fractional internal position error monitoring in radiotherapy. Mean and standard deviation of 6D calculation error, Hausdorff distance of point cloud after registration and the running time of each part of the program were calculated to verify the feasibility of the system. Fifteen real patients were selected to calculate the 6D error between the system and cone beam CT (CBCT).Results:In the phantom experiment, the errors of the system in the x, y and z axes were (1.292±0.880)mm, (1.963±1.115)mm, (1.496±1.045)mm, respectively, and the errors in the rotation, pitch and roll directions were 0.201°±0.181°, 0.286°±0.326°, 0.181°±0.192°, respectively. For real patients, the translational error of the system was within 2.6 mm, the rotational error was approximately 1°, and the program run at 1-2 frames/s. The precision and speed met the radiotherapy requirement. Conclusion:The 3D point cloud radiotherapy real-time monitoring system based on depth camera can automatically complete the positioning verification before radiotherapy, real-time monitoring of body position during radiotherapy, and provide error visual feedback, which has potential clinical application value.

2.
Chinese Journal of Radiological Health ; (6): 724-730, 2022.
Article in Chinese | WPRIM | ID: wpr-965551

ABSTRACT

@#<b>Objective</b> To investigate the dosimetric effect of truncated regions in computed tomography (CT) images on the targets and organs at risk in volumetric modulated arc therapy (VMAT) for middle thoracic esophageal cancer. <b>Methods</b> CT images of 15 patients with middle thoracic esophageal cancer were selected. Circle masks were used to make the volume of the truncated region account for 10%, 20%, 30%, and 40% of the arm volume, and the corresponding truncated CT images were obtained. The real CT was denoted as CT0. Two radiotherapy plans were made on CT0. One plan was VMAT_1F with full arcs, and the other one was VMAT_3F with arm avoidance. The plans were transplanted to four truncated CT, respectively, and the dosimetric differences between different plans were compared using Wilcoxon signed-rank test. <b>Results</b> Compared with VMAT_1F in CT0, <i>D</i><sub>mean</sub> and <i>V</i><sub>5</sub> of the lung decreased in VMAT_3F, but <i>D</i><sub>max</sub> of the spinal cord, <i>D</i><sub>mean</sub> of the heart, and <i>V</i><sub>20</sub> of the lung increased. In VMAT_3F, there was no statistically significant difference between the dosimetric parameters in the four truncated CT and those in CT0 (all <i>P</i> > 0.05). In VMAT_1F, except for homogeneity index and <i>D</i><sub>max</sub> of the spinal cord, the dosimetric parameters in four truncated CT were significantly different from those in CT0 (<i>P</i> < 0.05). The dosimetric difference increased with the increase in truncated region-to-volume ratio. <b>Conclusion</b> Complete CT data should be collected in clinical practice, and the radiation field avoiding the truncated regionshould be set if necessary to reduce the influence of the truncated region on dosimetry.

3.
Chinese Journal of Radiation Oncology ; (6): 1292-1296, 2021.
Article in Chinese | WPRIM | ID: wpr-910553

ABSTRACT

Objective:To explore the volume resolution of prostate motion target by four-dimensional (4D) ultrasound.Methods:The prostate ultrasound model was selected, and the group comparison study was conducted using 4D ultrasound to outline the prostate target under different motion amplitudes (A) and motion period (T). The simulated A value was set as 0.5 mm, 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm, respectively. The T value was set as 1 s, 2 s, 3 s, and 4 s, respectively. The volume of the target of the model prostate was calculated, and the static ultrasound image of the target was used as the control group to analyze the difference between two groups.Results:When the model was still, the size of the target of ultrasound was consistent with that of CT scan ( P>0.05). When the A values were 0.5 mm and 1 mm, there was no statistical difference between the volume in period 1-4 s and the volume in the target at rest (all P>0.05). When the A values were 2 mm and 3 mm, and the T values were 1 s, 2 s and 3 s there was statistical difference between the volume of target and that of of static ultrasonic target (all P<0.05). When the A value was 2 mm and the T value was 4 s, there was no statistical difference between the target volume and the static target volume ( P=0.710). The range within the group was 6.7 cm 3, and the standard deviation was 1.15 cm 3. When the A value was 3 mm and the T value was 4 s, the volume repeatability of the target was poor, and the range within the group was 14.4 cm 3; when the A values were 4 mm and 5 mm, and the T values were 1-4 s, the range within the group was 3.27-17.63 cm 3 and 6.51-21.02 cm 3, respectively. The volume repeatability of the target under each period was extremely poor, which could not meet the clinical requirements. Conclusion:4D ultrasound can provide reliable reference data for patients′ target delineation within 1-4 s of motion cycle and within 1 mm of motion amplitude, which exerts on effect upon the original position of probe.

4.
Chinese Journal of Radiological Medicine and Protection ; (12): 492-498, 2021.
Article in Chinese | WPRIM | ID: wpr-910345

ABSTRACT

Objective:To develop a 3D visualization technology-assisted patient positioning system for radiotherapy and compare it with traditional patient positioning method for breast and pelvic radiotherapy.Methods:A total of 40 patients receiving radiotherapy in Changzhou No.2 People′s Hospital from June 2020 to April 2021 were selected for this study, including 20 patients with breast cancer and 20 patients with pelvic cancer.3D visualization reconstruction was carried out using the CT data of the patients for positioning. Then the 3D visualization models were integrated with the real treatment environment and were then shifted to the isocentral positions of accelerators through interactive operations. Based on this, the patients were actually positioned. Every week, all of the patients were firstly treated with traditional positioning, followed by 3D visualization-guided positioning. As a result, 240 times of positioning data of all patients were collected in three weeks. They were compared with the data of cone-beam CT(CBCT)-guided positioning, which served as the gold standard.Results:The absolute positioning errors of 3D visualization-guided positioning along x, y and z axes were (1.92±1.23), (2.04±1.16), and (1.77±1.37)mm, respectively for patients with breast cancer and were (2.07±1.08), (1.33±0.88), and (1.99±1.25)mm, respectively for patients with pelvic cancer. Compared with traditional positioning method , the accuracy of 3D visualization-guided positioning along x、 y, and z axes was increased by 38.83%, 52.40% and 33%, respectively for patients with breast cancer and was improved by 36.84%, 54.04% and 52.58% for patients with pelvic cancer, with all differences being statistically significant along y and z axes ( t=2.956-5.734, P< 0.05). Meanwhile, the error distribution of the two positioning method was statistically significant along in y axis for patients with breast cancer( χ2=7.481, P<0.05) and was statistically significant along each axis for patients with pelvic cancer( χ2=5.900, 6.415, 7.200, P<0.05). Conclusions:The positioning method guided by 3D visualization technology can effectively improve the positioning accuracy of patients with breast cancer and patients with pelvic cancer and is of value in potential clinical application.

5.
Chinese Journal of Radiological Health ; (6): 366-370, 2021.
Article in Chinese | WPRIM | ID: wpr-974383

ABSTRACT

Medical images can provide clinicans with accurate and comprehensive patients’ information. Morphological or functional abnormalities caused by various diseases can be manifested in many aspects. Although MR images and CT images can highlight the medical image data of different tissue structures of patients, single MR images or CT images cannot fully reflect the complexity of diseases. Using MR image to predict CT image is one of the cross-modal prediction of medical images. In this paper, the methods of MR image prediction for CTmage are classified into four categoriesincluding registration based on atlas, based on image segmentationmethod, based on learning method and based on deep learning method. In our research, we concluded that the method based on deep learning should bemore promoted in the future by compering the existing problems and future development of MR image predicting CT image method.

6.
Chinese Journal of Radiological Medicine and Protection ; (12): 813-819, 2020.
Article in Chinese | WPRIM | ID: wpr-868531

ABSTRACT

Objective:To observe the effect and underlying mechanism of down-regulation of VEGFA on the radiosensitivity of esophageal cancer ECA-109 cells.Methods:Esophageal cancer cells were divided into four groups: sh-VEGFA group, vector control group, X-ray plussh-VEGFA group and X-ray plus vector group. The expressions of VEGFA gene and protein were detected by qPCR and Western blot, respectively. Cell proliferation and survival was measured by CCK8 assay and cloning formation, respectively. Cell apoptosis was detected by flow cytometry, and γ-H2AX foci were detected by immune-fluorescence assay.Results:Compared with the vector group, the expression of VEGFA gene was decreased in sh-VEGFA group ( t=11.98, P<0.05), and the expression of VEGFA protein was also reduced( t=12.38, P<0.05). After VEGFA being down-regulated, the cell proliferation( A450)was obviously inhibited( t=2.78, 7.25, 21.93, 13.21, P<0.05), and the cell clone formation of the sh-VEGFA group was significantly decreased so that D0, Dqand SF2 of sh-VEGFA group were decreased( t=5.83, 8.56, 7.68, P<0.05), and SERD0and SERDqwere increased. Compared with the vector group, the apoptosis rate in the sh-VEGFA group and the X-ray group was significantly increased and further increased in the sh-VEGFA plus X-ray group( t=17.63, 22.48, 33.87, P<0.05), and the number of γ-H2AX foci in both sh-VEGFA and vector groups were significantly increased within 2 h after X-ray irradiation. At 24 h after irradiation, the number of γ-H2AX foci returned to normal level in the vector group but remained at a higher level in the sh-VEGFA group ( t=7.00, P<0.05). Conclusions:Down-regulation of VEGFA inhibits the proliferation and colony formation, promotes apoptosis and hence increases the radiosensitivity of esophageal carcinoma cells via a pathway related to DNA damage repair.

7.
Chinese Journal of Radiation Oncology ; (6): 297-301, 2019.
Article in Chinese | WPRIM | ID: wpr-745299

ABSTRACT

Objective An improved method for obtaining pseudo-computed tomography (CT ps) based on ultrasound deformation field.Methods The three-dimensional image data of computed tomography and ultrasound for three postoperative cervical cancer patients were selected,including the CT (CTsim) and ultrasound (USsim) images obtained during the simulated positioning stage,and the cone beam CT (CBCT) and ultrasound images obtained during the positioning verification stage of the treatment one week later.Binary masks of the OROI and OROW were created and applied in ultrasound image registration;thus,the deformation field was obtained.The deformation field was applied to CTsim images and different pseudo-CT images were obtained.Similarities between these pseudo-CT images and those of CBCT were compared,and registration accuracies between pseudo-CT images under different binary masks and CTsim were discussed.Results The averages of the correlation coefficient between pseudo-CT based on OROI,OROW,no binary mask and CBCT were 0.95,0.82 and 0.64 respectively.The average of the normalized mean square Error were 0.12,0.42 and 0.57 respectively.Conclusion The pseudo-CT based on OROI binary mask matches the best with CTsim and achieves the highest similarity with CBCT.

8.
Chinese Journal of Radiation Oncology ; (6): 680-684, 2018.
Article in Chinese | WPRIM | ID: wpr-708260

ABSTRACT

Objective To compare the dose difference between the 12-bit and 16-bit CT images containing metallic implants calculated by different algorithms. Methods The titanium alloy rod was inserted into the phantom and subject to CT scan and then the 12-bit and 16-bit CT images were reconstructed. The CT images were online transmitted to the Monaco planning system and a 0° of single field was designed. The dose distribution was calculated by PB (Pencil Beam), CC (Collapsed Cone) and MC (Monte Carlo) algorithms, respectively. The CT-ED curve was expanded and the dose was recalculated. The depth dose curve through the center of the metallic implants along with the direction of the field was obtained by using the Matlab 8. 3 statistical software. The dose distribution curves between 12-bit and 16-bit CT images calculated by different algorithms and the dose difference of varying distances between the incident and the exit surfaces of metallic implants were statistically compared. The dose was measured by thimble chamber. Results The 16-bit CT images accurately read the CT values of the metallic implants. After the CT-ED curve was expanded, the dose on the incident surface of metallic implant was reduced by 5. 43% and that on the exit surface was increased by 25. 56% calculated by PB algorithm compared with MC algorithm. The dose on the posterior exit surface was higher than that of MC algorithm. The dose on the incident surface of metallic surface was decreased by 4. 5%, whereas that on the exit surface was reduced by 4. 31% using CC algorithm. The dose on the posterior exit surface was more significantly reduced. The calculated values by MC algorithm were the most close to the measured values. Conclusions Application of 16-bit CT image, CT-ED curve expansion of the treatment planning system combined with MC algorithm can enhance the accuracy of dose calculation for the patients containing metallic implants during radiotherapy.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 819-823, 2018.
Article in Chinese | WPRIM | ID: wpr-708140

ABSTRACT

Objective To predict the tolerance range of set-up errors in clinical practice by predicting the virtual set-up errors of postoperative radiotherapy patients for breast cancer. Methods A retrospective analysis was made of the patients who underwent radiotherapy after breast cancer surgery in recent 3 years. According to different treatment method, 10 cases of breast cancer after modified radical mastectomy and 10 cases after breast conserving radical mastectomy were selected. The target area was delineated, the volume modulated radiation therapy plan was made, the virtual moving error of the center point of the plan was moved, and the maximum moving error was 5 mm by 1 mm step. After recalculating the dose, the corresponding data including the clinical target areas ( CT ) , CTV ( V50 ) , average heart volume, V20 of the affected lung and CTV volume were recorded. SPSS 19. 0 software was used for statistical analysis, and repeated measurement of variance analysis was used to analyze the changes of the actual dose in the target area after moving the center point. Linear regression analysis method was used to analyze the correlation between the CTV volume and the dose change after the CTV moving midline. Results The virtual set-up error had little influence on the axis direction of the approximate mammary tangent direction, while the vertical direction of the approximate mammary tangent direction had greater influence. After moving more than 3 mm on the vertical axis, the CTV ( V50 ) decreased to below 90%, which was lower than the general requirement for the target area of CTV. Statistical analysis of set-up errors in all directions showed that there was significant difference in dosimetric changes ( F=34. 182, 12. 877, 16. 443, 9. 846, 46. 829, 10. 122, 57. 931, P <0. 05) in all directions except the B direction of left breast set-up errors (P>0. 05). Between breast conserving surgery and modified radical mastectomy, there was little effect on target movement. Through correlation analysis, it was found that the volume of CTV in the target area of breast cancer patients was linearly related to the errors caused by the movement of B, C and B directions of left breast and right breast(F=5. 733, 18. 496, 6. 630, P<0. 05). Conclusions In postoperative radiotherapy for breast cancer, the errors perpendicular to the section of breast should be paid special attention to whether left or right breast. When the error of this direction exceeds 3 mm, CTV is obviously less than V50 below 83. 85%. The effect of set-up error on the dose of CTV was not related to the operation mode of breast cancer and there was no obvious correlation with the volume of the target area.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 938-945, 2017.
Article in Chinese | WPRIM | ID: wpr-666019

ABSTRACT

Objective To apply metal artifact reduction algorithm to reduce metal artifacts based on 12 bit and 16 bit CT images,and aimed to analyze the effects on CT value and dose distribution.Methods The metal implant was inserted into the phantom,and the original 12 bit CT image and original 16 bit CT image were derived from CT scanning.The images were processed using NMAR algorithm,so the corrected 12 bit image and corrected 16 bit image were obtained.A patient's CT was chosen with artificial femur,and used the NMAR algorithm to reduce metal artifacts.Furthermore,the CT values of original images and corrected images were compared and analyzed.In the planning system,dose distribution was calculated based on each image by same radiation treatment plan.The dose distribution difference of each image was compared and analyzed.Results For the 12 bit image,the CT value of metal was 3 071 HU,which was much smaller than the metal's actual CT value ll 080 HU.The metal's CT value for the 16bit image was 11 098 HU,which was very close to the actual value.The original CT images contained a lot of artifacts around the metal,resulting in a large deviation of CT values from the reference image.After NMAR correction,metal artifacts were reduced significantly,and the CT values were close to the reference images.The dose distribution of the corrected 16 bit image was closest to that of the reference image.The maximum dose deviation on the central axis was 1.8%.The difference between the 12 bit image and the reference image downstream the metal was notable,and the maximum dose deviation on the central axis was 81.6%.The X-rays passed through the artifact region in original image,the dose distribution was obviously different from the reference image,and the maximum dose deviation was 21.6%.Conclusions For the patient with metal implant,using the NAMR algorithm on the 16 bit image result in accurate CT value of CT image,so that the accurate dose distribution will be obtained.

11.
Chinese Journal of Medical Imaging Technology ; (12): 1792-1796, 2017.
Article in Chinese | WPRIM | ID: wpr-664848

ABSTRACT

Radiomics refers to the comprehensive quantification of information such as tumor biological feature and heterogeneity through assessing a large number of quantitative image features from ROI of CT,MRI and PET images.With the development of data science,radiomics has been paid more and more attention.Feature extraction is an important step of Radiomics.The processes in feature extraction of radiomics were reviewed in this paper.

12.
Chinese Journal of Radiological Medicine and Protection ; (12): 306-310, 2017.
Article in Chinese | WPRIM | ID: wpr-512178

ABSTRACT

Objective To investigate the impact on registration accuracy with the different registration ranges of CBCT images and CT images.Methods CBCT and CT scans were performed on the of 5 patients.The registration ranges of five patients' images of abdomen,head and chest performed CBCT and CT scanning were processed with four modes.Mode 1:the registration range of CT images was larger than the registration range of CBCT images,mode 2:the registration range of CT images and CBCT images were equally,mode 3:taking a 5 cm translation of CT images range from mode 2,mode 4:The CBCT range and CT range reduced 2 cm both sides simultaneously from mode 2.Using the registration program from Insight Segmentation and Registration Toolkit (ITK) to the four modes,the Mean Square Difference (MSD) metric values of four modes after registration were compared and the relationship between mode 2 and another three modes was analyzed by paired t test.Results For the MSD metric values,mode 3 was maximum,mode 2 and 4 were minimum,and mode 1 was centered.The difference between the mode 2 and mode 4 was not statistically significant(P > 0.05).The difference between the mode 2 and mode 1 was statistically significant(t =-4.586,-4.164,-5.618,P < 0.05).The difference between the mode 2 and mode 3 was statistically significant(t =-6.423,-8.109,-19.601,P<0.05).Conclusion The registration ranges of CBCT and CT images has a certain extent of influence on the accuracy of image registration.The closer the registration range of CBCT and CT is,the higher the registration accuracy is.

13.
Chinese Journal of Medical Imaging Technology ; (12): 616-619, 2017.
Article in Chinese | WPRIM | ID: wpr-608696

ABSTRACT

More and more patients were treated by surgery with metal implants in clinic.Metal artifacts in CT images caused by metal implants brought challenges for postoperative evaluation and diagnosis of tumor.It also led to the possibility of missed diagnosis and misdiagnosis.In recent decades,the improved methods based on filtered-backprojection and iterative reconstruction algorithms have great progresses in reducing effects of metal artifacts.The actuality of techniques for metal artifact reduction were reviewed in this article.

14.
International Journal of Biomedical Engineering ; (6): 49-53, 2016.
Article in Chinese | WPRIM | ID: wpr-489569

ABSTRACT

Intensity-modulated radiation therapy is widely used in the treatment of tumor,and the dose distribution highly conforms to tumor target area in three-dimension.However,the factors such as complex beam,data error,algorithm error and machine error may cause large dose deviation in intensity-modulated radiation therapy,which may lead to unnecessary radiation accident.Therefore,standing on the patients' safety point of view,dose verification is usually performed before executing the treatment plan in order to ensure the safe implementation of the treatment plan and to avoid un-planned irradiation dose.Currently,there are many tools and methods of dose verification in clinic,including point dose verification tools like finger-shaped ionization chamber and thermoluminescence dosimeter;two-dimensional dose verification tools like Mapcheck,MatriXX and films;three-dimensional dose verification tools like ArcCHECK,Delta4 and the third-party software.These common clinical dose verification methods are reviewed in this paper.

15.
Chinese Journal of Radiation Oncology ; (6): 168-171, 2016.
Article in Chinese | WPRIM | ID: wpr-487115

ABSTRACT

Objective To study the detective sensitivity for position of multi-leave collimators ( MLC) using Delta-4. Methods First,the small positional deviation of MLC was simulated and measured using the linac (Varian,Trubeam) equipped with EPID.Then,two beam fields 2. 0 cm (x)×6. 0 cm (y), 7. 0 cm (x)×6. 0 cm (y) were designed,the x1 and x2 of MLC were expanded 0. 1 mm,0. 2 mm,0. 3 mm... 0. 9 mm and 1. 0 mm,2. 0...5. 0 mm to external simultaneously,different parameters of 3 mm/3%,2. 5 mm/2. 5%,2 mm/2%, 1. 5 mm/1. 5% and 1 mm/1% were used in Gamma analysis to analyze the difference between dose distribution detected by Delta-4 and original dose distribution with unexpanded MLC position derived from TPS. Results For 2. 0 cm ( x) × 6. 0 cm ( y) beam field, the pass rate of original dose distribution was 100%,and that decreased to 95. 5% when x1 ,x2 of MLC were expanded 0. 3 mm to external, and decreased to 89. 4% when expanded 0. 5 mm at 2. 5 mm/2. 5% statistical standards. For 7. 0 cm ( x) × 6. 0 cm ( y) beam field,the pass rate of original dose distribution was 96. 5%,and that decreased to less than 95% when x2,x2 of MLC were expanded 0. 3 mm to external,and passing rate was above 90% when MLC expanded less than 0. 5 mm at 1. 5 mm/1. 5% statistical standards. Conclusions For MLC' s positional deviation in decimillimeter level,raise standards of Gamma analysis properly may improve the capability of Delta-4 for detecting small positional deviation,but it won' t detect all the positional deviation of MLC in decimillimeter level. For different size of beam field,it is proposed to use different analytical standards for Delta-4.

16.
Chinese Journal of Radiation Oncology ; (6): 1248-1254, 2016.
Article in Chinese | WPRIM | ID: wpr-501791

ABSTRACT

Objective To reconstruct 16?bit images of metal implants using the extended function of computed tomography ( CT) imaging, and to analyze the effect of the metal CT value on calculation of dose distribution by evaluation of metal CT values in different scanning conditions. Methods A stainless steel rod and a titanium rod were inserted in a phantom. The 12?and 16?bit images and CT value distribution of metal implants were obtained by scanning the phantom using 120 kV tube voltage and 230 mA tube current. The 16?bit images and CT value distribution of metal implants were obtained by scanning the phantom using fixed tube current ( 230 mA) with varied tube voltage ( 100, 120, and 140 kV) or fixed tube voltage ( 120 kV) with varied tube current ( 180, 230, and 280 mA) . In the Varian treatment planning system, a single?field plan and a parallel?opposed field plan were designed based on the CT images. The dose distribution was calculated and compared by the paired t test. Results The CT values of the stainless steel rod and the titanium rod were both 3 071 HU in 12?bit CT images. In 16?bit CT images;however, the CT value of the stainless steel rod was significantly larger than that of the titanium rod. There were no significant differences in CT value of 16?bit image and dose distribution in radiotherapy plan between three scanning conditions with different tube currents. Under three scanning conditions with different tube voltages, the maximum CT values were 13 568, 13 127, and 12 295 HU for the stainless steel rod and 8 420, 7 140, and 6 310 HU for the titanium rod, respectively. Conclusions High?density metal implants cannot be distinguished by 12?bit images, while the distribution of metal CT value can be obtained by 16?bit images. The dose distribution of metal implants based on 12?bit images is different from that based on 16?bit images. Changes in tube voltage cause substantial changes in the CT value for metal implants, leading to changes in dose distribution in radiotherapy. Variation of tube current within a certain range causes slight changes in metal CT value and dose distribution.

17.
International Journal of Biomedical Engineering ; (6)2015.
Article in Chinese | WPRIM | ID: wpr-601632

ABSTRACT

Computed tomography (CT) has been widely used in clinical diagnosis and made a great contribution to diagnosis by providing anatomical information with high-resolution.However,when metal implants exist in patients' body,reconstructed CT images are seriously interfered by metal artifacts.Metal artifacts are usually expressed as many dark and bright radiant streak artifacts which seriously reduce diagnosis reliability and bring errors into the calculation of dose distribution in radiotherapy.Therefore,the study of metal artifact reduction (MAR)is of great importance.This article reviews main methods on MAR developed in recent years,and give deep analysis on some of the methods.