Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Ultrasonography ; (12): 1045-1049, 2019.
Article in Chinese | WPRIM | ID: wpr-824455

ABSTRACT

Objective To investigate the value of contrast-enhanced ultrasound(CEUS)in differential diagnosis of complex renal cysts and clear renal cell carcinoma with cystic change(CRCCC).Methods The ultrasonographic datas of 82 lesions in 82 patients with complicated renal cysts or CRCCC confirmed by pathology were analyzed.The characteristics of conventional ultrasound and CEUS were observed and evaluated.The lesions were graded according to Bosniak classification criteria.Results Pathological examination showed that 36 cases were complicated renal cysts and 46 cases were CRCCC. Routine ultrasound showed there were 9 cases (25.0%) with cystic masses and 27 cases (75.0%) with solid and cystic masses in complex renal cysts,of which 14 cases (38.9%) could detect color flow signals.In CRCCC,2 cases(4.3%)were with cystic masses and 44 cases(95.7%)were with solid and cystic masses, of which 33 cases(75.0%)could detect color flow signals.CEUS showed that only 18 cases(50.0%)of the complex renal cysts showed enhancement of cystic wall or septum,with equal or low enhancement at the peak,9 cases(50.0%) accompanied by decrease of renal cortex,35 cases (97.2%) had thin and regular cystic wall,no enhancement of cystic wall in all lesions,and 33 cases(91.7%)had septal thickness less than 1 mm.Forty-five cases (97.8%) of CRCCC showed enhancement of cystic wall or septum,40 cases(88.9%)showed equal or high enhancement at peak,30 cases(66.7%)were faster than the decrease of renal cortex,37 cases (80.4%) showed uneven thickness of cystic wall,24 cases (52.2%) showed enhancement of cystic wall nodules,and 28 cases (60.9%) showed uneven thickness of septum.After CEUS,33 cases(91.7%)of complex renal cysts were classified as grade Ⅰ and Ⅱ,while 42 cases(91.3%) of CRCCC were classified as grade Ⅲ and Ⅳ.Conclusions The CEUS manifestations of complex renal cysts are different from those of CRCCC.The application of Bosniak criteria in CEUS is helpful for the differential diagnosis of complex renal cysts and CRCCC.

2.
Chinese Journal of Ultrasonography ; (12): 1045-1049, 2019.
Article in Chinese | WPRIM | ID: wpr-800517

ABSTRACT

Objective@#To investigate the value of contrast-enhanced ultrasound(CEUS) in differential diagnosis of complex renal cysts and clear renal cell carcinoma with cystic change(CRCCC).@*Methods@#The ultrasonographic datas of 82 lesions in 82 patients with complicated renal cysts or CRCCC confirmed by pathology were analyzed. The characteristics of conventional ultrasound and CEUS were observed and evaluated. The lesions were graded according to Bosniak classification criteria.@*Results@#Pathological examination showed that 36 cases were complicated renal cysts and 46 cases were CRCCC. Routine ultrasound showed there were 9 cases (25.0%) with cystic masses and 27 cases (75.0%) with solid and cystic masses in complex renal cysts, of which 14 cases (38.9%) could detect color flow signals. In CRCCC, 2 cases (4.3%) were with cystic masses and 44 cases (95.7%) were with solid and cystic masses, of which 33 cases (75.0%) could detect color flow signals. CEUS showed that only 18 cases (50.0%) of the complex renal cysts showed enhancement of cystic wall or septum, with equal or low enhancement at the peak, 9 cases (50.0%) accompanied by decrease of renal cortex, 35 cases (97.2%) had thin and regular cystic wall, no enhancement of cystic wall in all lesions, and 33 cases (91.7%) had septal thickness less than 1 mm. Forty-five cases (97.8%) of CRCCC showed enhancement of cystic wall or septum, 40 cases (88.9%) showed equal or high enhancement at peak, 30 cases (66.7%) were faster than the decrease of renal cortex, 37 cases (80.4%) showed uneven thickness of cystic wall, 24 cases (52.2%) showed enhancement of cystic wall nodules, and 28 cases (60.9%) showed uneven thickness of septum. After CEUS, 33 cases (91.7%) of complex renal cysts were classified as grade Ⅰ and Ⅱ, while 42 cases (91.3%) of CRCCC were classified as grade Ⅲ and Ⅳ.@*Conclusions@#The CEUS manifestations of complex renal cysts are different from those of CRCCC. The application of Bosniak criteria in CEUS is helpful for the differential diagnosis of complex renal cysts and CRCCC.

3.
Chinese Journal of Ultrasonography ; (12): 786-790, 2014.
Article in Chinese | WPRIM | ID: wpr-466109

ABSTRACT

Objective To investigate the value of contrast-enhanced ultrasound (CEUS) in diagnosis of renal epithelioid angiomyolipoma (eAML).Methods The CEUS features of 18 patients with 18 histopathologically proved renal eAMLs were retrospective analyzed using both of qualitative and quantitative approachs.Tumor conventional ultrasound and CEUS features were observed.The Sonoliver software was applied to perform quantitative analysis,which provided five parameters,including the maximum intensity (IMAX),rise time (RT),time to peak (TTP),mean transit time (mTT) and area under the curve (AUC).Results All of 18 lesions were pathological proved as eAML,among them,heterocyst was observed in 7 lesions,1 lesion had dissemination inter-kidney and vessel invasion,necrosis or cystic degeneration was found in 3 eAMLs.On conventional ultrasound,eAML showed hypoecho,isoecho and hyperecho were 14(77.8%),3(16.7%) and 1 (5.6%) respectively.Blood flow could be detected in 16 (88.9%) lesions.On CEUS,the characters of slow-in,synchronous-in,slow centripetal enhancement and entire enhancement were observed in 10 (55.6%),8 (44.4%),8 (44.4%) and 12 (55.6%) lesions,respectively.Most of eAMLs showed homogeneous enhancement (15/18,83.3%) and hyper-or iso-enhancement (16/18,88.8 %) at peak time.The characters of fast-out,synchronous-out and slow out were observed in 8 (44.4%),2 (11.2%) and 8 (44.4%) cases,respectively.Pseudocapsule was detected in 5 (27.8%) lesions.The parameters of RT,TP and AUC for eAMLs were higher than that for renal cortex (P < 0.05),while the parameters of IMAX and mTT had no significant statistical difference between eAMLs and renal cortex(P >0.05).Conclusions Qualitative and quantitative analysis of CEUS reflect the blood perfusion of eAMLs in different aspect,which offer some useful informations for the diagnosis of eAMLs.

4.
Chinese Journal of Ultrasonography ; (12): 526-528, 2012.
Article in Chinese | WPRIM | ID: wpr-426047

ABSTRACT

ObjectiveTo investigate the influence of different depths and mediums on tissue stiffness measurement by virtual touch tissue quantification technology.Methods Four kinds of in vitro porcine tissue were recruited,three (fat,muscle and liver) were assigned as medium group and three (kidney,liver and muscle) as sample group.The shear wave velocity (Vs) of the samples was measured under different mediums and at different depths (2 cm,3 cm,4 cm and 5 cm),respectively.ResultsAccording to the depth of measurement,two groups of Vs were defined with one group at the depth of 2 cm and 3 cm while the other at 4 cm and 5 cm.The difference of Vs between the two groups was of statistical significance and with the increase of the depth Vs values decreased.Even at the same depth,the differences of Vs under different mediums were statistically significant.ConclusionsDepths and mediums have great influence on evaluating elasticity measurements by virtual touch tissue quantification technology.

5.
Chinese Journal of Ultrasonography ; (12): 164-166, 2012.
Article in Chinese | WPRIM | ID: wpr-424728

ABSTRACT

Objective To investigate the usefulness of acoustic radiation force impulse (ARFI) elastography for noninvasive evaluation of liver fibrosis in rats.Methods A total of 70 male Wistar rats were included in the group for dimethylnitrosamine (DMN)-induced liver injury,and 10 saline-injected rats were used as normal control.Hepatic injury was induced by a single intraperitoneal injection of DMN at a dose of 50 mg/kg of body weight.Several rats in the group with DNM injected and the normal control group were randomly selected and sacrificed at each of the following post-injection time:day 5,7,10,14,21,24,and 28.And their livers were taken for pathology analysis.All the rats underwent ARFI elastography before sacrificed in order to acquire a shear wave velocity (Vs) to represent liver stiffness.Correlation between Vs and the histological finding was analysed.ResultsAmong 58 successfully modeled rats,9,13,14 and 12 rats were found to be with S1,S2,S3 and S4 of liver fibrosis pathologically,respectively.And 10 rats were found to be with severe inflammatory activity without any fibrosis.Values of Vs increased with the stage of liver fibrosis ( P <0.05).There was a significant correlation between Vs and stage of liver fibrosis ( r =0.947,P =0.000).The areas under ROC curve for the diagnosis of fibrosis S≥S1,S≥S2,S≥S3 and S=S4 were 0.983,0.995,0.999 and 0.964,respectively;for the cutoff values of Vs were 1.59 m/s,2.13 m/s,2.33 m/s and 2.51 m/s,respectively,the sensitivity was 95.8%,92.3%,100% and 84.6%,and specificity was 100%,100%,96.9% and 95.6%,respectively.The values of Vs in the group with severe inflammatory activity were significantly higher than those in the control group ( P =0.000).ConclusionsARFI has a relatively high value in the evaluation of liver fibrfosis in rats,while severe inflammatory activity may affect its accuracy.

6.
Chinese Journal of Ultrasonography ; (12): 872-875, 2012.
Article in Chinese | WPRIM | ID: wpr-423562

ABSTRACT

Objective To investigate the features of quantitative analysis and parametric imaging of contrast-enhanced ultrasound (CEUS) in renal clear cell carcinoma (ccRCC).Methods Ninety-seven pathologically confirmed ccRCCs underwent conventional ultrasound and CEUS.Both quantitative parameters and dynamic vascular pattern (DVP) reconstructure were analyzed with Sonoliver software.Four types of DVP curves were described with type Ⅰ (Unipolar +),type Ⅱ (Bipolar + /-),type Ⅲ (Bipolar -/+) and type Ⅳ (Unipolar-),while the DVP parametric images,similarly,were divided into four types,with type Ⅰ,Ⅱ,Ⅲ and Ⅳ,respectively.Results As for the parameter of CEUS,there were statistical differences in maximum intensity (IMAX),area under the curve (AUC) and mean transit time (mTT) (P <0.05) and no statistic differences in rise time (RT) and time to peak (TTP) between ccRccs and peripheral renal parenchyma.Concerning of DVP of ccRCCs,type Ⅰ,Ⅱ,Ⅲ and Ⅳ accounted for 58.8% (57/97),11.3% (11/97),10.3% (10/97) and 19.6% (19/97) respectively.As for each type in DVP parametric images,the percentages were 58.8% (57/97),11.3% (11/97),8.2% (8/97),21.7% (21/97),respectively.Conclusions Quantitative analysis and parametric imaging can depict different features of vascularity in ccRCCs and improve the diagnosis of the tumors.

SELECTION OF CITATIONS
SEARCH DETAIL