Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J. bras. nefrol ; 33(4): 463-466, out.-nov.-dez. 2011.
Article in Portuguese | LILACS | ID: lil-609060

ABSTRACT

INTRODUÇÃO: O papel da aldosterona na fisiopatologia da disfunção endotelial relacionada à síndrome metabólica (SM) tem sido objeto de estudos. OBJETIVO: Avaliar o bloqueio da aldosterona sobre a vasodilatação fluxo mediada (VDFM) e sobre parâmetros renais e metabólicos em indivíduos com SM. MÉTODOS: Dezenove indivíduos com SM foram submetidos a exame clínico; exames complementares: glicose, insulina, lipidograma, depuração da creatinina, microalbuminúria e a monitorização ambulatorial da pressão arterial (MAPA) e análise da VDFM antes e após 16 semanas do uso de espironolactona. RESULTADOS: Após o tratamento, observou-se aumento da VDFM, de 7,6 ± 5,63 por cento para 15,0 ± 6,10 por cento (p < 0,001), com redução não significante da pressão sistólica e diastólica (142,2 ± 16,37 mmHg para 138,8 ± 16,67 mmHg e 84,3 ± 10,91 mmHg para 82,7 ± 9,90 mmHg, respectivamente). O colesterol HDL (High-density lipoprotein - lipoproteína de alta densidade) aumento de modo significante, a microalbuminúria apresentou tendência à redução, enquanto a depuração da creatinina não variou significativamente com o tratamento. CONCLUSÃO: O bloqueio da aldosterona em pacientes com SM melhorou a VDFM, sem induzir alterações no perfil metabólico e em parâmetros renais.


INTRODUCTION: The role of aldosterone in the pathophysiology of the metabolic syndrome (MS)-related endothelial dysfunction has been the subject of recent research. OBJECTIVE: To evaluate the effects of aldosterone blockade on flow-mediated vasodilation (FMD) and on renal and metabolic parameters of patients with the MS. METHODS: 19 MS subjects underwent clinical examination, laboratory work-up (serum lipid profile, glucose and insulin; creatinine clearance; microalbuminuria investigation), ambulatory blood pressure monitoring (ABPM), and FMD analysis before and after 16 weeks of aldosterone blockade with spironolactone. RESULTS: After the treatment period, FMD increased from 7.6 ± 5.63 percent to 15.0 ± 6.10 percent (p < 0.001), associated with a non-significant decrease of blood pressure (from 142.2 ± 16.37 mmHg to 138.8 ± 16.67 mmHg, and from 84.3 ± 10.91 mmHg to 82.7 ± 9.90 mmHg, respectively). HDL-cholesterol significantly increased, microalbuminuria showed a decreasing trend and creatinine clearance did not change after treatment. CONCLUSION: Aldosterone blockade in patients with the MS improved FMD without interfering with metabolic and renal parameters.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Mineralocorticoid Receptor Antagonists/therapeutic use , Endothelium, Vascular/drug effects , Endothelium, Vascular/physiopathology , Metabolic Syndrome/physiopathology , Spironolactone/therapeutic use , Vasodilation/drug effects , Prospective Studies
2.
Arq. bras. cardiol ; 97(6): 493-501, dez. 2011. ilus, tab
Article in Portuguese | LILACS | ID: lil-610394

ABSTRACT

FUNDAMENTO: Diversos métodos têm sido utilizados para avaliar a modulação vagal cardíaca; entretanto, há lacunas quanto a associação e acurácia desses métodos. OBJETIVO: Investigar a associação entre três métodos válidos, reprodutíveis e comumente utilizados para avaliação da modulação vagal cardíaca, e comparar as suas acurácias. MÉTODOS: Trinta homens saudáveis (23 ± 4 anos) e 15 homens com coronariopatia (61 ± 10 anos) foram avaliados em ordem contrabalanceada pela Variabilidade da Frequência Cardíaca (VFC; variáveis: domínio do tempo = pNN50, DPNN e RMSSD, domínio da frequência = AF ms² e AF u.n.), Arritmia Sinusal Respiratória (ASR) e Teste de Exercício de 4 segundos (T4s). RESULTADOS: Indivíduos saudáveis apresentaram maior modulação vagal nos três métodos (p < 0,05). No grupo saudável houve correlação (p < 0,05) entre os resultados da VFC (pNN50 e DPNN) e da ASR, mas não houve correlação entre o T4s e os outros dois métodos estudados. No grupo com coronariopatia houve correlação entre os resultados da VFC (pNN50, DPNN, RMSSD, AF ms² e AF u.n.) e da ASR. Em adição, houve correlação entre o T4s e a ASR. Por fim, os métodos ASR e T4s apresentaram tamanho do efeito mais preciso e melhor acurácia (p < 0,05) comparados à VFC. CONCLUSÃO: A VFC e a ASR geraram resultados parcialmente redundantes em indivíduos saudáveis e em pacientes com coronariopatia, enquanto o T4s gerou resultados complementares a VFC e ASR em indivíduos saudáveis. Além disso, os métodos ASR e T4s foram mais precisos para discriminar a modulação vagal cardíaca entre indivíduos saudáveis e pacientes com coronariopatia comparados à VFC.


BACKGROUND: Several methods have been used to assess cardiac vagal modulation, but there are gaps regarding the association and accuracy of these methods. OBJECTIVE: To investigate the association between three valid, reproducible and commonly methods used to assess cardiac vagal modulation and compare their accuracies. METHODS: Thirty healthy men (23 ± 4 years) and 15 men with coronary artery disease (61 ± 10 years) were evaluated in counterbalanced design by Heart Rate Variability (HRV; variables: the time domain = pNN50, SDNN and RMSSD, the frequency domain HF = ms² and HF n.u.), Respiratory Sinus Arrhythmia (RSA) and 4-second Exercise Test (T4s). Thirty healthy men (23 ± 4 years) and 15 men with coronary artery disease (61 ± 10 years) were evaluated in counterbalanced order by Heart Rate Variability (HRV; variables: the time domain = pNN50, SDNN and RMSSD, the frequency domain HF = ms² and HF n.u.), Respiratory Sinus Arrhythmia (RSA) and 4-second Exercise Test (T4s). RESULTS: Healthy subjects had higher vagal modulation by the three methods (p <0.05). There was a correlation in the healthy group (p <0.05) between the results of HRV (SDNN and pNN50 and RSA, but there was no correlation between the T4s and the other two methods. In the group with coronary artery disease, there was a correlation between the results of HRV (pNN50, SDNN, RMSSD, HF ms² and HF n.u.) and RSA. In addition, there was a correlation between the RSA and T4s. Finally, the T4s and RSA methods presented more accurate effect size and better accuracy (p <0.05), when compared to the HRV. CONCLUSION: HRV and RSA generated partially redundant results in healthy subjects and in patients with coronary artery disease, while the T4s generated results that were complementary to HRV and RSA in healthy subjects. In addition, RSA and T4s methods were more accurate when discriminating cardiac vagal modulation between healthy subjects and patients with coronary artery disease, when compared to HRV.


Subject(s)
Adult , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Young Adult , Arrhythmia, Sinus/physiopathology , Autonomic Nervous System Diseases/diagnosis , Coronary Disease/physiopathology , Exercise Test/methods , Heart Rate/physiology , Vagus Nerve/physiology , Epidemiologic Methods , Respiration
3.
Arq. bras. cardiol ; 94(5): 580-584, maio 2010. graf, tab
Article in Portuguese | LILACS | ID: lil-548116

ABSTRACT

FUNDAMENTO: O teste de exercício de 4 segundos (T4s) avalia o tônus vagal cardíaco durante o transiente inicial da frequência cardíaca (FC), em exercício dinâmico súbito, por meio da identificação do índice vagal cardíaco (IVC) obtido a partir do eletrocardiograma (ECG). OBJETIVO: Testar a utilização do monitor de frequência cardíaca (MFC) Polar S810 como recurso alternativo ao ECG na aplicação do T4s. MÉTODOS: Neste trabalho, 49 indivíduos do sexo masculino (25 ± 20 anos, 176 ± 12 cm, 74 ± 6 kg) realizaram o T4s. Os intervalos RR foram registrados simultaneamente por ECG e MFC. Calcularam-se média e desvio padrão do último intervalo RR do período pré-exercício ou o primeiro do período de exercício, aquele que for mais longo (RRB), do mais curto intervalo RR do período de exercício (RRC) e do IVC obtidos por ECG e MFC. Utilizou-se o teste t de Student para amostras dependentes (p < 0,05) para testar a significância das diferenças entre as médias. Para identificar a concordância entre o ECG e o MFC, utilizou-se a regressão linear, com cálculo do coeficiente de correlação de Pearson e a estratégia proposta por Bland e Altman. RESULTADOS: A regressão linear apresentou r² de 0,9999 para o RRB, 0,9997 para o RRC e 0,9996 para o IVC. A estratégia de Bland e Altman apresentou desvio padrão de 0,92 ms para o RRB, 0,86 ms para o RRC e 0,002 para o IVC. CONCLUSÃO: O MFC Polar S810 se mostrou eficiente na aplicação do T4s quando comparado ao ECG.


BACKGROUND: The 4-second exercise test (T4s) evaluates the cardiac vagal tone during the initial heart rate (HR) transient at sudden dynamic exercise, through the identification of the cardiac vagal index (CVI) obtained from the electrocardiogram (ECG). OBJECTIVE: To evaluate the use of the Polar S810 heart rate monitor (HRM) as an alternative resource to the use of the electrocardiogram in the 4-second exercise test. METHODS: In this study, 49 male individuals (25 ± 20 years, 176 ±12 cm, 74 ± 6 kg) underwent the 4-second exercise test. The RR intervals were recorded simultaneously by ECG and HRM. We calculated the mean and the standard deviation of the last RR interval of the pre-exercise period, or of the first RR interval of the exercise period, whichever was longer (RRB), of the shortest RR interval of the exercise period (RRC), and of the CVI obtained by ECG and HRM. We used the Student t-test for dependent samples (p < 0.05) to test the significance of the differences between means. To identify the correlation between the ECG and the HRM, we used the linear regression to calculate the Pearson's correlation coefficient and the strategy proposed by Bland and Altman. RESULTS: Linear regression showed r² of 0.9999 for RRB, 0.9997 for RRC, and 0.9996 for CVI. Bland e Altman strategy presented standard deviation of 0.92 ms for RRB, 0.86 ms for RRC, and 0.002 for CVI. CONCLUSION: Polar S810 HRM was more efficient in the application of T4s compared to the ECG.


Subject(s)
Adult , Humans , Male , Electrocardiography/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Exercise Test/instrumentation , Heart Rate/physiology , Epidemiologic Methods , Electrophysiologic Techniques, Cardiac/methods , Exercise Test/methods , Vagus Nerve/physiology
SELECTION OF CITATIONS
SEARCH DETAIL