Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Rev. argent. cardiol ; 91(1): 20-26, abr. 2023. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1529566

ABSTRACT

RESUMEN Objetivo : Analizar si la estrategia del implante alto usando superposición de las cúspides derechas e izquierdas (Cusp Overlap, COVL) en el implante percutáneo de la válvula aórtica (TAVI) se relaciona con menor incidencia de regurgitación paravalvular (RPV) moderada o grave, comparada con la estrategia convencional (CON). Material y métodos : Se analizaron 206 pacientes consecutivos que recibieron TAVI con válvulas autoexpandidles entre agosto de 2019 y mayo de 2022. Se utilizó una estrategia CON en 101 pacientes (49%) y COVL en 105 (51%). El Punto Final Primario (PFP) fue la presencia de regurgitación paravalvular moderada y grave a 30 días. Resultados : No hubo diferencia clínica entre los grupos en cuanto a la edad media, sexo ni comorbilidades; excepto una tendencia a más diabetes y angioplastia coronaria previa en el grupo COVL. El STS score fue mayor en el grupo de COVL (6,9 ± 2,2 vs. 5,8 ± 2,4 en CON, p = 0,01). A 30 días no hubo diferencia en el PFP (RPV moderada en 2% en CON, y 0,9% en COVL; ninguno presentó RPV grave). Tampoco hubo diferencia en mortalidad, infarto, oclusión coronaria, accidente cerebrovascular, sangrado mayor y complicación vascular. La necesidad de marcapasos definitivo fue menor con la estrategia de COVL (6,7% vs. 17,8%, p = 0,01) y un nuevo bloqueo de rama izquierda ocurrió en 5,7% vs. 12,9% (p = 0,07). Conclusiones : En esta serie de un solo centro, la estrategia del implante alto de la válvula aórtica percutánea usando la técnica de COVL no demostró diferencia en la presencia de regurgitaciones moderadas o graves comparada con la estrategia convencional, sin presentar diferencia en las complicaciones, y se asoció a una menor necesidad de marcapasos definitivo y a una tendencia de menos bloqueos de rama izquierda a 30 días.


ABSTRACT Objective : The aim of this study is to whether higher transcatheter aortic valve implantation (TAVI) with self-expandable valves using the right and left cusp overlap strategy (Cusp Overlap, COVL) is associated with a lower incidence of moderate or severe paravalvular regurgitation, compared with the conventional strategy (CON). Methods : A total of 206 consecutive patients undergoing TAVI with self-expandable valves between August 2019 and May 2022 were analyzed. The CON technique was used in the first 101 patients (49%) and COVL was used in 105 (51%). The primary endpoint (PEP) was the presence of moderate or severe paravalvular regurgitation at 30 days. Results : There were no clinical differences between the groups in terms of mean age, sex or comorbidities, except for a trend towards more patients with diabetes and previous percutaneous coronary intervention in the COVL group. The STS score was greater in the COVL group (6.9 ± 2.2 vs. 5.8 ± 2.4 in the CON group; p = 0.01). There was no difference in the PEP at 30 days with 2% incidence of moderate PVR in the CON group and 0.9% in the COVL group, and none of them presented severe PVR. There were no differences in mortality, myocardial infarction, coronary artery obstruction, stroke, major bleeding or vascular complications. The need for permanent pacemaker was lower with the COVL strategy (6.7% vs. 17.8%, p = 0.01) and a new left bundle branch block occurred in 5.7% vs. 12.9% (p = 0.07). Conclusions : In this single-center series, the strategy of high transcatheter aortic valve implantation using the COVL strategy showed no difference in the presence of moderate or severe regurgitation compared with the conventional strategy, with no differences in complications, and was associated with a lower need for definitive pacemaker and with a trend towards lower incidence of left bundle branch block at 30 days.

2.
Rev. argent. cardiol ; 90(2): 112-119, abr. 2022. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1407125

ABSTRACT

RESUMEN Objetivo: Analizar si el implante más alto en el implante percutáneo de válvula aórtica (TAVI) con válvulas auto-expandibles utilizando la superposición de las cúspides derecha e izquierda disminuye la necesidad de marcapasos definitivo. Material y Métodos: Se analizaron 164 pacientes consecutivos que recibieron TAVI con válvulas auto- expandibles; en 101(61,6%) de ellos se implantaron utilizando la vista coplanar de las tres cúspides, a la cual llamamos técnica convencional (CON) y en 63 (38,4%) utilizamos la técnica COVL, con superposición de las cúspides derecha e izquierda . El punto final primario (PFP) fue la necesidad de marcapasos definitivo (MCPD) a 30 días. Resultado: No hubo diferencias entre los grupos en la edad media, prevalencia de sexo masculino, hipertensión, cirugía de revascularización previa, antecedente de accidente cerebrovascular (ACV), función renal, o hemodiálisis. Los pacientes en el grupo COVL tuvieron más diabetes, angioplastia coronaria (ATC) e infarto previos. La ATC pre-TAVI fue similar, con mayor score STS (6,3 ± 2,1 vs. 5,8 ± 2,4; p = 0,05). La presencia de fibrilación auricular fue mayor en el grupo COVL sin diferencia en bloqueo auriculoventricular, de rama derecha o izquierda. No hubo diferencia en el área valvular aórtica, gradiente medio y fracción de eyección ventricular izquierda. A 30 días se observó una reducción significativa del PFP en la estrategia COVL, (6,3% vs 17,8%, p = 0,03). No hubo diferencia en mortalidad, ACV, sangrado mayor, infarto agudo de miocardio o regurgitación aórtica. Hubo tendencia a menor presencia de nuevo bloqueo competo de rama izquierda en el grupo COVL (4,8% vs. 12,9%, p = 0,08). Conclusiones: El uso de la técnica de COVL, que permite un implante más alto en el TAVI con válvulas autoexpandibles, demostró en esta serie ser factible y seguro, con disminución de la necesidad de MCPD sin aumento de las complicaciones.


ABSTRACT Objective: The aim of this study was to analyze whether higher transcatheter aortic valve implantation with self-expandable valves using the right and left cusp overlap strategy decreases the need for permanent pacemaker. Methods: A total of 164 consecutive patients undergoing TAVI with self-expandable valves were analyzed: 101 (61.6%) implanted with the conventional technique (CON) using the three-cusp coplanar view, and 63 (38.4%) using the right and left cusp overlap (COVL) technique. The primary endpoint (PEP) was the need for permanent pacemaker (PPM) at 30 days. Results: Mean age, prevalence of male gender, hypertension, prior coronary artery bypass graft surgery (CABG), and history of stroke, kidney function or hemodialysis was not different between groups. Patients in the COVL group had more diabetes, coronary percutaneous transluminal coronary angioplasty (PTCA) and prior infarct, and pre-TAVI PTCA was similar, with higher STS score (6.3±2.2 vs. 5.8±2.4; p=0.05). The presence of atrial fibrillation was greater in the COVL group, without differences in right or left bundle branch or atrioventricular block. There was no difference in aortic valve area, mean gradient and left ventricular ejection fraction. At 30 days, the need of PPM was significantly reduced with the COVL technique (6.3%% vs. 17.8%; p=0.03). No difference was observed in mortality, stroke, major bleeding, acute myocardial infarction or aortic regurgitation, and the presence of new-onset complete left bundle branch block was lower in the COVL group (4.8% vs. 12.9%; p=0.08). Conclusions: Use of the COVL technique, which allows higher self-expandable valve implantation during TAVI, was feasible and safe, decreasing the need for PPM without increasing complications.

3.
Rev. argent. cardiol ; 90(1): 57-61, mar. 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1407111

ABSTRACT

RESUMEN Introducción: La endocarditis infecciosa (EI) post implante percutáneo de válvula aórtica (TAVI) es poco frecuente, con una alta tasa de morbimortalidad. Métodos: Se analizaron 630 pacientes consecutivos con TAVI, de los cuales 6 (0,95%) presentaron EI. Resultados: Cuatro eran hombres, edad 81,3 ± 2,2 años, y todos sintomáticos. La fracción de eyección ventricular izquierda (FEVI) fue 56,8 ± 5,3%. Todos recibieron un implante exitoso y uno presentó regurgitación moderada. Dos requirieron marcapaso definitivo, a uno de ellos se le debió recolocar el cable a las 24 hs. La EI se presentó a los 63,5 ± 73,3 días (mediana de 35 días). El germen aislado fue un coco (+) en cuatro casos. En uno se observó una vegetación en el ecocardiograma transesofágico. Un paciente falleció dentro de los 30 días. El seguimiento fue a 23 ± 22 meses, ningún paciente presentó nuevos eventos o internaciones. En el eco Doppler la FEVI fue de 55,9 ± 4,6%, el gradiente medio 8,2 ± 1,8 mmHg y la velocidad pico de 1,8 ± 0,2 m/seg. Un paciente terminó una regurgitación moderada. Conclusiones: En esta serie de pacientes, la EI post TAVI fue poco frecuente y presentó una evolución favorable con el tratamiento antibiótico.


ABSTRACT Background: Infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is a rare complication with high morbidity and mortality. Methods: Of 630 consecutive patients undergoing TAVI, 6 (0.95%) presented IE. Results: Four patients were men, mean age was 81.3 ± 2.2 years and all the patients were symptomatic. Left ventricular ejection fraction (LVEF) was 56.8 ± 5.3%. The procedure was successful in all the patients and one presented moderate regurgitation. Two patients required definitive pacemaker and the lead had to be reimplanted 24 hours later in 1 patient. Time to IE was 63.5 ± 73.3 days (median 35 days). A Gram-positive coccus was isolated in four cases. One patient presented a vegetation on transesophagic echocardiography. One patient died within 30 days. During follow-up of 23 ± 22 months none of the patients presented new events or hospitalizations. On Doppler echocardiography, LVEF was 55.9 ± 4.6%, mean trans-aortic gradient was 8.2 ± 1.8 mm Hg and peak systolic velocity was 1.8 ± 0.2 m/s. One patient had moderate regurgitation. Conclusions: In this series of patients, IE after TAVI was uncommon and had a favorable course with antibiotic treatment.

7.
Rev. argent. cardiol ; 88(5): 434-439, set. 2020. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1251017

ABSTRACT

RESUMEN Introducción: Los aneurismas de aorta siguen siendo una patología frecuente, en especial aquellos localizados en la aorta abdominal. Desde 1990, gracias al avance en los dispositivos y las técnicas endovasculares, la cirugía convencional ha dejado de ser la única opción de tratamiento. Presentamos nuestros resultados en el manejo del aneurisma de aorta con técnica endovascular mínimamente invasiva. Objetivos: Analizar los resultados a 30 días del implante de endoprótesis en la aorta torácica y abdominal con una estrategia mínimamente invasiva. Material y métodos: Entre marzo de 2012 y abril de 2019 se realizaron 395 implantes consecutivos de endoprótesis de aorta; en 264 (67%) de los cuales se utilizó una técnica mínimamente invasiva (MIN-A). De este grupo 240 procedimientos (90,9%) fueron llevados a cabo para reparar la aorta abdominal (EVAR) y 24 (9,1%) la aorta torácica (TEVAR). Resultados: De 264 pacientes se logró éxito técnico (ET) del implante en el 99,6% y éxito clínico (EC) en el 97,7%. La mortalidad a 30 días fue del 1,1% dado por neumonía, insuficiencia cardíaca y EPOC. Ningún paciente presentó IAM, ACV o necesitó de conversión a reparación quirúrgica de urgencia. El tiempo promedio del procedimiento fue de 62 minutos (SD ± 17). Algunos pacientes requirieron conversión a cierre quirúrgico del acceso [20 (7%) durante los primeros 100 casos, y 7 (3%) en los últimos 164 pacientes p = 0,05)]. El sangrado mayor que requirió transfusión fue del 1,1%. El tiempo promedio para la deambulación fue de 18 horas (SD ± 10), que luego de los primeros 100 pacientes disminuyó en forma significativa a 13 horas (SD ± 2,9 p = 0,05). La estadía hospitalaria en promedio fue de 1,4 días (SD ± 1,14) con 5 casos externados el mismo día del procedimiento. Conclusiones: Los procedimientos de reparación endovascular de aneurismas de la aorta con una estrategia miniinvasiva fueron factibles y seguros, ya que permitieron convertir estos procedimientos en abordajes percutáneos, con bajas tasas de complicaciones asociadas al acceso, menor tiempo quirúrgico, rápida deambulación y menor estadía hospitalaria, sin modificar la seguridad global del procedimiento. La curva de aprendizaje permitió bajar la tasa de conversiones a cirugía, así como los tiempos de deambulación.


ABSTRACT Background: Aortic aneurysms, particularly of the abdominal aorta, are still common. Since 1990, conventional surgery is no longer the only treatment option due to advances in endovascular devices and techniques. We present our results in the management of aortic aneurysms with a minimally invasive endovascular technique. Objectives: The aim of this study was to analyze the 30-day outcomes of endograft implantation in the thoracic aorta and abdominal aorta using a minimally invasive approach. Methods: Between March 2012 and April 2019, 395 consecutive endografts were implanted in the aorta, and 264 (67%) were performed using a minimally invasive approach (MIN-A). Among this group, 240 (90.9%) corresponded to abdominal endo-vascular aortic repair (EVAR) and 24 (9.1%) to thoracic endovascular aortic repair (TEVAR). Results: Technical success (TS) of the implant was achieved in 99.6% of the 264 patients and clinical success (CS) in 97.7%. Thirty-day mortality was 1.1% due to pneumonia, heart failure and chronic obstructive pulmonary disease. There were no cases of myocardial infarction, stroke or need for conversion to urgent surgical repair. Mean duration of the procedure was 62 minutes (SD ± 17). Some patients required conversion to surgical closure of the access site [20 (7%) during the first 100 cases and 7 (3%) in the final 164 patients, p = 0.05]. Three (1.1%) patients presented major bleeding requiring transfusion. Mean time to ambulation was 18 hours (SD ± 10) that significantly decreased to 13 hours after the first 100 patients (SD ± 2.9; p= 0.05). Mean length of hospital stay was 1.4 days (SD ± 1.14) with 5 patients discharged on the same day of the procedure. Conclusions: Endovascular aortic aneurysm repair using a minimally invasive strategy was feasible and safe, turning this procedure into a percutaneous approach, with low access site-related complications, shorter operative time, rapid ambulation and shorter length of hospital stay, without modifying overall safety of the procedure. The learning curve resulted in reduced rate of conversion to surgery and earlier ambulation.

8.
Medicina (B.Aires) ; 80(5): 516-522, ago. 2020.
Article in Spanish | LILACS | ID: biblio-1287205

ABSTRACT

Resumen La estenosis aórtica grave es una enfermedad común cuya prevalencia crece con el envejecimiento de la población. El reemplazo valvular aórtico quirúrgico (SAVR) ha sido la única alternativa efectiva hasta la aparición del reemplazo valvular aórtico por cateterismo (TAVR o TAVI). Este procedimiento se usó inicialmente para pacientes inoperables en quienes dos ensayos clínicos aleatorios y varios registros mostraron su superioridad sobre el tratamiento médico conservador. Dos ensayos clínicos adicionales en pacientes que, a pesar de ser considerados operables, tenían alto riesgo quirúrgico, demostraron la no inferioridad de TAVR versus reemplazo quirúrgico. Investigaciones posteriores probaron también su efectividad en pacientes de riesgo intermedio y bajo. Algunas complicaciones, como las relacionadas al acceso vascular, el accidente cerebro vascular, la necesidad de marcapasos definitivo y la regurgitación periprotésica, han ido disminuyendo con la mejoría de la tecnología, la curva de aprendizaje y la estrategia mínimamente invasiva actual. Queda pendiente determinar la durabilidad para establecer cuál será el papel de TAVR en la práctica clínica.


Abstract Severe aortic stenosis is a common disease whose prevalence is steadily growing with population ageing. Surgical aortic valve replacement (SAVR) has been the only effective alternative until the introduction of transcatheter aortic valve replacement (TAVR or TAVI). This procedure was initially used for non-surgical candidate patients where two randomized clinical trials and several registries showed superiority over conservative medical treatment. Furthermore, two additional clinical trials including high surgical risk patients proved the non-inferiority of TAVR versus surgical replacement. Similar findings regarding effectiveness were observed in other clinical trials including intermediate and low risk patients. Technical and procedural improvements, including learning curve and the current minimally invasive strategy have decreased periprocedural and mid-term complications such as those related with vascular access, stroke, the need for permanent pacemaker implantation and paravalvular leak. All things considered, durability is a pending question to establish which would be the role of TAVR in current and future practice.


Subject(s)
Humans , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/surgery , Stroke , Forecasting
11.
Rev. argent. cardiol ; 87(4): 273-279, jul. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1125759

ABSTRACT

RESUMEN Introducción: El reemplazo de válvula aórtica transcatéter (TAVR) se está convirtiendo en un procedimiento estándar para pacientes con alto riesgo quirúrgico que necesitan el reemplazo de la válvula aórtica. Esta técnica ha evolucionado rápidamente y la llamada estrategia minimalista está ganando adeptos en todo el mundo, mientras la evidencia en su favor todavía se está acumulando. Objetivo: Analizar los resultados a 30 días de la estrategia minimalista (MIN-A) en comparación con la técnica convencional (CON-A) en la experiencia de un solo centro. Material y métodos: Entre septiembre de 2009 y febrero de 2018, se realizaron 303 procedimientos consecutivos de TAVR por acceso femoral, 229 (75,6%) de ellos con MIN-A y 74 (24,4%) con CON-A. Resultados: La edad promedio de los pacientes fue de 79,5 años y ambos grupos tenían características similares. No hubo diferencias entre estos en lo referido a hipertensión, diabetes, tabaquismo, ICP o CRM previa, IAM, EPOC, fibrilación auricular y diálisis. La ATC por etapas antes del TAVR (procedimiento combinado) y la insuficiencia renal (eGFR < 60 ml / min / 1,73 m2) fueron más frecuentes en los sometidos a CON-A. El score del STS fue similar en ambos grupos. El tiempo del procedimiento fue menor en el grupo MIN-A (125 ± 26 vs. 211 ± 48 minutos; p < 0,001), al igual que el tiempo de hospitalización (4,1 vs. 6,3 días; p = 0,01). A los 30 días, no hubo diferencias en la mortalidad (3,9% frente a 1,4%; p = 0,29), IAM, accidente cerebrovascular, hemorragia, transfusión y complicaciones vasculares. Cuatro pacientes tuvieron falla del dispositivo de cierre (1 requirió reparación quirúrgica, 3 requirieron stent cubierto). Las fugas paravalvulares (PVL) moderadas fueron más frecuentes en el grupo CON-A (11,8% vs. 23%; p = 0,01), pero las PVL graves tuvieron similar incidencia (1,3% vs. 2,7%). Conclusión: La estrategia minimalista en el implante percutáneo de la válvula aórtica demostró ser factible y segura; dicha estrategia disminuyó el tiempo del procedimiento y la estadía en el hospital, con similares resultados clínicos que la estrategia convencional a 30 días, pero con mejor confort para el paciente.


ABSTRACT Background: Transcatheter aortic valve implantation (TAVI) is becoming the standard procedure for high-risk patients requiring aortic valve replacement. This technique has evolved rapidly and the so-called minimalist strategy is gaining worldwide attention, while supporting evidence is still being assembled. Objective: The aim of this study was to compare 30-day outcomes of the minimalist approach (MA) versus the standard approach (SA) for TAVI performed in a single center. Methods: Between September 2009 and February 2018, 303 consecutive TAVI procedures were performed, 229 (75.6%) using the MA and 74 (24.4%) with the SA. Results: Mean age was 79.5 years and both groups had similar characteristics. There were no differences in hypertension, diabetes, smoking habits, previous percutaneous coronary intervention (PCI) or coronary artery bypass graft surgery, acute myocardial infarction (AMI), chronic obstructive pulmonary disease, atrial fibrillation and dialysis. PCI before TAVI (combined procedure) and kidney failure (eGFR <60 ml / min / 1.73 m2) were more common in the SA group. The STS score was similar in both groups. The total duration of the procedure and in-hospital stay were lower in the MA group (125±26 vs. 211±48 minutes; p <0.001, and 4.1 vs. 6.3 days; p=0.01, respectively). There were no differences in mortality (3.9% vs. 1.4%; p=ns), incidence of AMI, stroke, major bleeding requiring transfusion or vascular complications at 30 days. The closure device failed in four patients (one underwent surgical repair and three required a covered stent). Moderate paravalvular leaks (PVL) were more frequent in the SA group (11.8% vs. 23%; p=0.01) but the incidence of severe PVL was similar (1.3% vs. 2.7%). Conclusion: The MA for TAVI proved to be feasible and safe, reducing the procedure duration and in-hospital stay, with 30-day outcomes similar to those of the SA but providing better comfort for the patient.

12.
Rev. argent. cardiol ; 87(3): 217-224, mayo 2019. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1057345

ABSTRACT

RESUMEN Objetivos: Reportar y analizar los resultados iniciales de una serie de pacientes con insuficiencia mitral (IM) grave sintomática y alto riesgo para cirugía que recibieron reparación percutánea de la válvula mitral (RPVM) con MitraClip®. Material y métodos: Entre marzo de 2016 y octubre de 2018 recibieron RPVM con MitraClip® en forma consecutiva 12 sujetos con IM grave sintomática, con alto riesgo o contraindicación para cirugía. Se consideró "éxito del implante" (EI) el correcto agarre de las valvas con el clip que dejó una IM residual leve o moderada al finalizar el procedimiento, y "éxito del procedimiento (EP) a 30 días" el EI en ausencia de eventos adversos mayores (MACE), los que incluyeron muerte, infarto agudo de miocardio (IAM), accidente cerebrovascular (ACV), necesidad de cirugía valvular, derrame pericárdico, taponamiento o sangrado mayor. Datos basales y antecedentes de los pacientes: la media de edad fue de 74,1 ± 8,9 años; 7 eran hombres; 3, diabéticos; 10 eran hipertensos y dislipidémicos; 4 eran tabaquistas, 5 tenían fibrilación auricular, 2 portaban marcapasos definitivo, 3 documentaban IAM previo, 2 habían sido sometidos antes a ATC y 4 a cirugía cardíaca. La tasa de filtración glomerular estimada (eGFR) fue de 73,8 ± 34,8 ml/m2, 2 tenían < 60 ml/m2 y uno se encontraba en diálisis. Todos los pacientes estaban en clase funcional (CF) III-IV, con antecedentes de internaciones por insuficiencia cardíaca (IC). Características ecográficas: diámetro diastólico del ventrículo izquierdo (DDVI): 61,8 ± 6,4 mm; diámetro sistólico (DSVI): 46,3±2,1 mm; fracción de eyección del ventrículo izquierdo (FEVI): 47,5±13,4% (rango: 25-60%). La causa de la IM era degenerativa en 7 pacientes y funcional en 5. La evaluación del riesgo mostró un EuroSCORElog de 9,6±6,8; el STS score de mortalidad fue 16,1 ±1 3,5 y el de morbimortalidad 22,8 ± 17,7. Resultados: Se obtuvo EI en todos los pacientes; en 7 enfermos se implantó 1 solo clip y en los otros 5 se colocaron 2 clips; el gradiente residual medio posimplante fue 3,6 ± 0,2 mmHg. La IM posprocedimiento fue leve en 11 y mínima en 1. La estadía hospitalaria media fue de 1,9 ± 0,8 días (rango: 1-3 días). A los 30 días, todos los sujetos se encontraban en CF I-II; ningún paciente presentó eventos mayores o reinternación por IC. El seguimiento abarcó a todos los pacientes y se extendió por un tiempo medio de 8,8 ± 6,7 meses (rango: 1-30 meses). Dos pacientes fallecieron: 1 de neumonía a los 14 meses y otro a los 30 meses por IC refractaria luego de un reemplazo valvular aórtico por cateterismo (TAVI), manteniendo IM leve. No hubo otras complicaciones. Todos se encontraban en CF I-II, 1 requirió reinternación por IC (a los 7 meses). El eco-Doppler cardíaco de seguimiento demostró IM leve en 11 pacientes y moderada a grave en 1. Hubo una mejoría en la calidad de vida en todos los casos. Conclusiones: En esta serie inicial de un solo centro y que incluye la curva de aprendizaje, la RPVM con MitraClip® en pacientes con IM grave sintomática y alto riesgo quirúrgico fue segura y efectiva, con una mejoría clínica significativa y también en la calidad de vida en el seguimiento.


ABSTRACT Objective: To analyze and report our initial outcomes of Percutaneous Mitral Valve Repair (PMVR) with MitraClip® for patients with severe symptomatic Mitral Regurgitation (MR) and high surgical risk. Methods: Between March 2016 and October 2018 twelve consecutive PMVR with MitraClip® were performed in patients with severe symptomatic MR and contraindication or high surgical risk. Implantation Success (IS) was defined as adequate leaflets grasping, leaving < moderate residual MR at the end of the procedure and 30-day Procedural Success when IS was achieved without any Major Adverse Cardiovascular Event (MACE: death, AMI, Stroke, need of valvular surgery, pericardial effusion, tamponade or major bleeding). Results: Mean age was 74.1±8.9 years, all of them had hypertension and Dyslipemia 7 were men, 3 diabetics, 4 smokers, 5 had previous atrial fibrillation, 2 permanent pacemakers, 3 previous AMI, 2 of them had received PCI and 4 cardiac surgery. The eGFR was 73.8±34.8 ml/m2, 2 had <60 ml/m2 and one on dialysis. All Ptes were in FC III-IV and history of previous hospitalizations because heart failure. Echocardiographic findings: Left Ventricle End Diastolic Diameter (LVEDD) 61.8±6.4, End Systolic Diameter (LVESD) 46.3±2.1; left ventricular ejection fraction (LVEF) 47.5±13.4 (25-60). MI were degenerative in 7 Ptes and functional in 5. Risk Scores: EuroSCORE log was 9.6±6.8, STS for mortality 16.1±13.5 and the STS for morbimortality of 22.8±17.7 EI was achieved in all Ptes; 1 Single Clip was implanted in 7 Pts and 2 Clips in 5; Mean residual post-implantation gradient was 3.6±0.2 mmHg. IS was achieved in all; post-procedural MR was mild in 11 and trivial in one. Mean length of hospital stay was 1.9±0.8 (1-3) days. At 30 days all were in FC 0-II, no one presented MACE or rehospitalization because heart failure. Follow-Up was performed in all Ptes with an average time of 8.8±6.7 (1-30) months. Two patients died (1 from pneumonia at 14 months and another at 30 months due to refractory cardiac failure after TAVI, maintaining mild MR.) There were no other complications, all were in FC I-II, one required rehospitalization due to heart failure (at 7 month). Echo Doppler at follow-Up showed that 11 Ptes had <2 MR and 1 had >2 MR. The QOL improved during the follow-up Conclusion: In this initial series, from a single center that includes the learning curve of the team, PMVR with MitraClip® in Ptes with severe mitral regurgitation and high surgical risk was safe and effective, with a significant clinical improvement at follow-up

13.
Rev. argent. cardiol ; 85(3): 1-10, jun. 2017. ilus
Article in Spanish | LILACS | ID: biblio-957775

ABSTRACT

Introducción: Es conocida la morbimortalidad quirúrgica en pacientes sometidos a doble reemplazo valvular por presentar estenosis aórtica grave e insuficiencia mitral significativa. Se ha sugerido que con posterioridad al reemplazo valvular aórtico percutáneo se produce una remodelación ventricular izquierda inversa con cambios favorables en las condiciones de carga y consecuente mejoría de la insuficiencia mitral. Objetivo: Evaluar el beneficio del reemplazo valvular aórtico percutáneo aislado en dichos pacientes y analizar la influencia de la disminución de la poscarga y la remodelación favorable del ventrículo izquierdo sobre la insuficiencia mitral. Material y métodos: Se evaluaron retrospectivamente 89 pacientes consecutivos de un único centro, sometidos a reemplazo valvular aórtico percutáneo entre marzo de 2009 y agosto de 2015, por presentar estenosis aórtica grave sintomática y riesgo quirúrgico alto. Se analizaron los ecocardiogramas antes del procedimiento y posteriormente al mes de seguimiento. Se identificaron 40 pacientes con insuficiencia mitral significativa, que corresponden a la muestra final y objeto de nuestra investigación. Resultados: La gravedad de la insuficiencia mitral basalmente se clasificó en grave (+4) en 5 pacientes (12,5%), moderada a grave (+3) en 18 (45%) y leve a moderada (+2) en 17 (42,5%). En el seguimiento se identificó insuficiencia mitral +4 en 1 paciente (2,5%), +3 en 12 pacientes (30%), +2 en 8 pacientes (20%), leve (+1) en 15 pacientes (37,5%) y sin insuficiencia en 4 pacientes (10%), siendo estos cambios estadísticamente significativos (p = 0,045). Conclusión: Nuestros resultados sugieren que en los pacientes con enfermedad bivalvular, descartados de tratamiento quirúrgico por riesgo alto, el reemplazo valvular aórtico percutáneo podría ser la principal opción terapéutica, dado que habría una alta probabilidad de que la insuficiencia mitral se reduzca luego del procedimiento.

14.
Rev. argent. cardiol ; 82(3): 211-217, jun. 2014. ilus, graf, tab
Article in Spanish | LILACS | ID: lil-734502

ABSTRACT

Introducción El implante valvular aórtico percutáneo es una opción terapéutica cada vez más utilizada en pacientes en los que se descarta la cirugía. A pesar de que las alteraciones agudas de la conducción son una de las complicaciones más frecuentes, su significado clínico y electrocardiográfico no es del todo claro. Objetivos Determinar las implicaciones pronósticas del desarrollo de alteraciones agudas de la conducción luego del implante valvular aórtico percutáneo. Resultados Entre marzo de 2009 y febrero de 2012 se incluyeron para el análisis 47 pacientes; de ellos, 30 (63%) presentaron alteraciones agudas de la conducción: 19 pacientes solo bloqueo completo de rama izquierda (BCRI), 9 pacientes solo bloqueo auriculoventricular completo (BAVC) y 2 pacientes presentaron ambos trastornos, los que totalizaron 21 BCRI y 11 BAVC. A 12 (25%) se les implantó un marcapasos definitivo previo al alta: en 11 por BAVC y en 1 por BCRI agudo más fibrilación auricular. En solo un paciente el BAVC revirtió en hemodinamia. Los pacientes que persistieron con BAVC posintervención presentaron una media de estimulación ventricular en la intervalometría al mes del 90%, mientras que en el paciente con BAVC que revirtió en hemodinamia fue de solo el 3% y en el paciente con BCRI más fibrilación auricular fue < 10%. La incidencia de insuficiencia cardíaca en el posoperatorio fue mayor en los pacientes con alteraciones agudas de la conducción (p = 0,007), al igual que la estadía hospitalaria (p = 0,045). En el seguimiento no hubo diferencias en la tasa de reinternación ni en la mortalidad. Conclusiones En el presente estudio el desarrollo de alteraciones agudas de la conducción mostró un aumento en la incidencia de insuficiencia cardíaca y en los días de internación, sin incremento en la tasa de otros eventos mayores. La colocación de un marcapasos definitivo luego del BAVC podría realizarse en forma inmediata, ya que el trastorno generalmente es irreversible.


Introduction The indication of transcatheter aortic valve implantation in patients considered not suitable candidates for surgery is increasing. Despite acute disorders of the conduction system are common complications, their clinical and electrocardiographic significance is not completely clear. Objectives To determine whether acute disorders of the conduction system after transcatheter aortic valve implantation has prognostic implications. Results Between March 2009 and February 2012, 47 patients were included in the analysis. Thirty patients (63%) had acute disorders of the conduction system: 19 patients presented isolated complete left bundle branch block (LBBB), 9 patients isolated complete atrioventricular block (CAVB), and 2 patients both conduction disorders, with a total of 21 LBBBs and 11 CAVBs. A definite pacemaker was implanted in 12 patients (25%) before discharge: in 11 due to CAVB and in 1 due to acute LBBB plus atrial fibrillation. Complete AVB reverted in the catheterization laboratory in only one patient. At one month, average ventricular pacing was 90% in patients with persistent CAVB after the intervention, only 3% in the only patient in whom CAVB reverted at the catheterization laboratory and < 10% in the patient with LBB plus atrial fibrillation. The incidence of postoperative heart failure and hospital stay was greater in patients with acute disorders of the conduction system (p = 0.007 and p = 0.045, respectively). There were no differences in new hospitalizations and mortality during follow-up. Conclusions In this study, the development of acute disorders of the conduction system was associated with increased incidence of heart failure and hospital stay but not with the incidence of major events. A definite pacemaker could be implanted immediately after CAVB develops as the conduction disorder is generally irreversible.

15.
Rev. argent. cardiol ; 80(5): 360-365, oct. 2012. ilus
Article in Spanish | LILACS | ID: lil-662173

ABSTRACT

Objetivo Describir la experiencia inicial con el implante directo de la prótesis aórtica autoexpandible CoreValve® en un centro argentino de alta complejidad cardiovascular. Material y métodos Desde mayo a diciembre de 2010 se incluyeron en forma consecutiva pacientes con estenosis aórtica grave (EAG) de alto riesgo sometidos a implante directo de prótesis CoreValve® (n = 21). Los criterios de inclusión fueron: área de la válvula aórtica < 1 cm2 (< 0,6 cm2/m2), anillo valvular aórtico de entre 20 y 27 mm, diámetro de la aorta ascendente a nivel de la unión sinotubular ≤ 40 (prótesis pequeña) o ≤ 43 mm (prótesis grande) y diámetro de la arteria femoral > 6 mm. Resultados La edad fue de 79 ± 8 años, el área valvular aórtica fue de 0,7 ± 0,2 cm2 y el EuroSCORE logístico fue del 26% ± 15% (50% con EuroSCORE logístico ≥ 20%). Tras el implante, el gradiente transaórtico máximo por ecocardiograma descendió de 80 ± 22 mm Hg a 14 ± 5 mm Hg. Dos pacientes presentaron insuficiencia aórtica de grado grave, que mejoraron luego de la posdilatación. La tasa de éxito del procedimiento fue del 95%, ya que un paciente falleció luego del implante valvular. Se implantó un marcapasos definitivo por bloqueo auriculoventricular en 6 pacientes. La sobrevida acumulada (media de seguimiento 5 ± 2,8 meses) fue del 75%. Conclusión Nuestra experiencia inicial sugiere que el implante directo de la prótesis CoreValve® es una opción terapéutica segura y factible para los pacientes con EAG de alto riesgo quirúrgico.


Objective To describe the initial experience with aortic valve implantation via a direct approach using a self-expanding CoreValveTM aortic valve prosthesis in a tertiary care center from Argentina. Material and methods From May to December 2010, 21 consecutive patients with severe aortic stenosis (SAS) and high surgical risk undergoing percutaneous aortic valve replacement with CoreValveTM prosthesis were included. The inclusion criteria were the following: aortic valve area <1 cm2 (<0.6 cm2/m2); aortic annulus diameter of 20-27 mm; diameter of the ascending aorta at the level of the sinotubular junction ≤ 40 (small prosthesis) or ≤ 43 mm (large prosthesis), and femoral artery diameter >6 mm. Results Mean age was 79±8 years, mean aortic valve area was 0.7±0.2 cm2 and mean logistic EuroSCORE was 26±15% (50% with logistic EuroSCORE ³ 20%). After valve implantation, peak transaortic pressure gradient measured by echocardiography decreased from 80±22 to 14±5 mm Hg. Two patients developed severe aortic regurgitation which improved with post-dilation. The success rate of the procedure was of 95% as a patient died immediately after valve implant. A definite pacemaker was implanted to six patients due to atrioventricular block. Cumulative survival was 75% after a mean follow-up of 5±2.8 months. Conclusion Our initial experience suggests that direct implantation of CoreValveTM prosthesis is a safe and feasible therapeutic option for patients with SAS and high surgical risk.

16.
Medicina (B.Aires) ; 71(5): 437-440, oct. 2011. ilus
Article in Spanish | LILACS | ID: lil-633893

ABSTRACT

La angina de pecho es un síntoma frecuente en pacientes con hipertensión pulmonar (HP) de cualquier etiología. Aunque su fisiopatología no está aclarada, las causas propuestas son: la isquemia subendocárdica por aumento del estrés parietal del ventrículo derecho, la dilatación de la arteria pulmonar por incrementos transitorios de la presión pulmonar y la compresión extrínseca del tronco de la arteria coronaria izquierda (TCI) por la arteria pulmonar (AP) dilatada. Se presentan tres casos que muestran la relación entre la angina de pecho y la compresión del TCI en pacientes con HP asociada a cardiopatías congénitas, tratados mediante implante de stent coronario.


Chest pain is a frequent symptom in patients with pulmonary hypertension of any etiology. Its pathophysiology has not been clearly established, the proposed causes are ischemia due to increased right ventricle wall stress, transient increased pulmonary hypertension resulting in acute pulmonary artery dilatation and external compression of the left main coronary artery (LMCA) by a dilated pulmonary artery. We report and discuss here three cases where the association between chest pain and compression of the LMCA by a dilated pulmonary artery could be shown, and they were treated with coronary stenting.


Subject(s)
Adult , Female , Humans , Angina Pectoris/etiology , Chest Pain/etiology , Eisenmenger Complex/complications , Hypertension, Pulmonary/complications , Stents , Angina Pectoris , Cineangiography , Eisenmenger Complex , Eisenmenger Complex/therapy , Hypertension, Pulmonary/therapy , Pulmonary Artery
17.
Rev. bras. cardiol. invasiva ; 17(4): 470-475, out.-dez. 2009. tab
Article in Portuguese | LILACS | ID: lil-543379

ABSTRACT

A magnitude da resolução do supradesnivelamento do segmento ST é um marcador de reperfusão miocárdica em pacientes com infarto agudo do miocárdio. A resolução incompleta do supradesnivelamento do segmento ST foi identificada como preditor de resultados desfavoráveis em pacientes com infarto agudo do miocárdio após terapia de reperfusão. Este estudo teve como objetivos descrever a frequência de resolução incompleta do supradesnivelamento do segmento ST em um registro contemporâneo de pacientes submetidos a angioplastia primária e fazer uma comparação de seus resultados hospitalares com pacientes que apresentaram resolução completa do supradesnivelamento do segmento ST. Método: Entre julho de 2008 e fevereiro de 2009, foram incluídos 183 pacientes consecutivos com infarto agudo do miocárdio (< 24 horas) de oito centros na Argentina em um registro prospectivo de infarto agudo do miocárdio com supradesnivelamento do segmento ST foi definida como redução < ou igual 70 por cento do supradesnivelamento do segmento ST no eletrocardiograma...


Subject(s)
Humans , Angioplasty, Balloon, Coronary , Myocardial Infarction/diagnosis , Reperfusion , Thrombolytic Therapy , Aspirin , Electrocardiography/methods , Electrocardiography
18.
Rev. bras. cardiol. invasiva ; 17(3): 340-345, jul.-set. 2009. tab, graf
Article in Portuguese | LILACS | ID: lil-535093

ABSTRACT

INTRODUÇÃO: O uso de tromboaspiração manual demonstrou melhorar a reperfusão miocárdica durante a intervenção percutânea primária. Entretanto, a população adequada para esse tratamento ainda não foi bem estabelecida. Este estudo teve como objetivo determinar a taxa de utilização e a seleção de pacientes para tromboaspiração manual durante intervenção percutânea primária. MÉTODO: No período de julho de 2008 a fevereiro de 2009, incluímos 183 pacientes com intervenção percutânea primária de oito centros argentinos em um registro prospectivo de infarto do miocárdio com supradesnivelamento do segmento ST (IAMCSST). As características clínicas, angiográficas e do procedimento e os desfechos clínicos foram comparados entre os pacientes tratados com e sem tromboaspiração manual. RESULTADOS: A tromboaspiração manual foi utilizada em 20,8% dos pacientes. As características clínicas basais foram, em geral, semelhantes entre os pacientes tratados com e sem tromboaspiração manual. Entretanto, os pacientes tratados com tromboaspiração manual tinham pior função renal pré-procedimento e maior somatória de supradesnivelamento do segmento ST basal (12,2 ± 7,7 mm vs. 10,2 ± 8,6 mm; P = 0,06). O grupo com tromboaspiração manual apresentou maior proporção de pacientes com trombo graus 4-5 (86,8% vs. 49%; P < 0,01), maior fluxo TIMI 0 basal (tromboaspiração manual: 63,2% vs. 40,7%; P = 0,03), maior diâmetro do vaso (3,46 ± 0,5 mm vs. 3,12 ± 0,5 mm; P = 0,01), e maior utilização de filtro distal (13,1% vs. 0,7%; P = 0,04) e de balão intra-aórtico (10,5% vs. 3,4%; P = 0,05), assim como de inibidores da glicoproteína IIb/IIIa (39,5% vs. 14,5%; P = 0,04). A taxa de resgate de material aterotrombótico macroscópico foi de 76,3%. Embora o grupo com tromboaspiração manual apresentasse pico mais elevado de creatina fosfoquinase (tromboaspiração manual: 3.195,9 ± 2.598 UI/ml vs. 1.757,6 ± 1.806,6 UI/ml; P = 0,02), a porcentagem de resolução do segmento ST e o fluxo TIMI 3 final não foram diferentes entre os grupos. A taxa de eventos cardiovasculares adversos maiores no acompanhamento foi semelhante (21,1% vs. 15,2%; P = 0,36). CONCLUSÃO: O emprego da tromboaspiração manual na prática diária em paciente com IAMCSST destina-se a pacientes de maior complexidade tanto clínica como angiográfica, acarretando, no final, resultados clínicos semelhantes aos de pacientes não tratados com tromboaspiração manual.


BACKGROUND: Manual thrombus-aspiration has proven to improve myocardial reperfusion during primary percutaneous coronary intervention. However, the adequate population for this approach has not been well established. The aim of this study was to determine the frequency and patient selection for thrombus-aspiration during primary percutaneous coronary intervention. METHOD: From July 2008 to February 2009, we included 183 patients submitted to primary percutaneous coronary intervention from eight Argentinean centers in a prospective ST-segment elevation myocardial infarction (STEMI) registry. Baseline characteristics as well as clinical and angiographic outcomes were compared among patients treated with and without thrombus-aspiration. RESULTS: Manual thrombus-aspiration was used in 20.8% of the patients. Baseline clinical characteristics were similar among patients treated with and without thrombus-aspiration. However, thrombus-aspiration treatment was associated with worse baseline renal function and greater baseline ST-segment elevation (thrombus-aspiration: 12.2 ± 7.7 mm vs. 10.2 ± 8.6 mm; P = 0.06). The thrombus-aspiration group had a higher rate of patients with grade 4-5 thrombus (86.8% vs. 49%; P < 0.01) and baseline TIMI flow 0 (thrombus-aspiration 63.2% vs. 40.7%; P = 0.03), greater vessel diameter (3.46 ± 0.5 mm vs. 3.12 ± 0.5 mm; P = 0.01), use of distal filter (13.1% vs. 0.7%; P = 0.04) and use of intra-aortic balloon (10.5% vs 3.4%; P = 0.05), as well as glycoprotein IIb/IIIa inhibitor administration (39.5% vs. 14.5%; P = 0.04). Debris was retrieved from 76.3% of the patients. Although the thrombus-aspiration group had higher CK levels (thrombus-aspiration: 3195.9 ± 2598 UI/ml vs. 1757.6 ± 1806.6 UI/ml; P = 0.02), the percentage of ST-segment resolution and final TIMI 3 flow did not differ between groups. The follow-up rate of major cardiovascular events was similar for both groups (thrombusaspiration: 21.1% vs. 15.2%; P = 0.36). CONCLUSION: Routine thrombus-aspiration in patients with STEMI is used in patients with higher clinical and angiographic complexity, leading to similar overall clinical results as those not treated with thrombus-aspiration.


Subject(s)
Humans , Male , Female , Middle Aged , Myocardial Infarction/therapy , Thrombectomy/methods , Thrombectomy , Coronary Thrombosis/complications , Coronary Thrombosis/diagnosis , Coronary Angiography/methods , Coronary Angiography
19.
Rev. argent. cardiol ; 77(3): 174-180, mayo-jun. 2009. graf, tab
Article in Spanish | LILACS | ID: lil-634080

ABSTRACT

Introducción La angioplastia primaria tiene una eficacia limitada ya que deja a un grupo considerable de pacientes sin lograr una reperfusión miocárdica tisular adecuada. Los factores clínicos, angiográficos y terapéuticos que influyen en el grado de reperfusión no han sido claramente establecidos. Objetivos Identificar los factores independientes asociados con la ausencia de reperfusión tisular luego de la angioplastia primaria. Material y métodos Se analizaron 140 pacientes incluidos prospectivamente en el estudio aleatorizado Protection of Distal Embolization in High-Risk Patients with Acute ST-Segment Elevation Myocardial Infarction Trial (PREMIAR). Este estudio evaluó la utilización de un filtro de protección distal durante la angioplastia en el infarto agudo de miocardio con supradesnivel del segmento ST en pacientes de alto riesgo trombótico (solamente incluyendo flujo coronario basal TIMI 0-2). El punto final primario fue la resolución completa del segmento ST a los 60 minutos, definida como disminución del ST ≥ 70% con el empleo de monitorización continua del segmento ST. Se desarrolló un modelo de regresión logística para identificar los predictores independientes. Resultados Se observó resolución completa del segmento ST a los 60 minutos luego de la angioplastia en 82 pacientes (63%), mientras que 53 pacientes (37%) presentaron resolución incompleta que se asoció con una tasa de mortalidad, reinfarto y/o insuficiencia cardíaca a los 30 días del 8,5% y 18,9%, respectivamente (p = 0,07). Los pacientes que no lograron una reperfusión tisular adecuada tuvieron con más frecuencia compromiso de localización anterior (79% versus 33%; p = 0,001), mayor frecuencia cardíaca (81 ± 20 versus 70 ± 15; p < 0,001) y menor proporción de fumadores actuales (25% versus 51%; p = 0,002) respecto de aquellos con reperfusión tisular óptima. Se observó además una tendencia a mayor presencia de diabetes (26% versus 16%; p = 0,13), mayor tiempo desde el inicio de los síntomas a la angioplastia (minutos) (217 ± 167 versus 182 ± 134; p = 0,19) y clase Killip > 1 (30% versus 17%; p = 0,07), respectivamente. El análisis multivariado demostró que el infarto de localización anterior (OR 8,22, IC 95% 3,67-18,4; p < 0,001) se asoció con ausencia de reperfusión completa, mientras que el uso de inhibidores de la glicoproteína IIb/IIIa (OR 4,21, IC 95% 1,34-13,22; p = 0,014) y el tabaquismo actual (OR 3,84, IC 95% 1,58-9,50; p = 0,003) se correlacionaron con una reperfusión completa. Conclusiones Una proporción considerable de pacientes sometidos a angioplastia primaria no logran una reperfusión tisular adecuada. Este fenómeno se asocia con peor pronóstico. La presencia de infarto de localización anterior se correlaciona con una extensión menor del grado de reperfusión tisular. Contrariamente, el tabaquismo actual y el uso de inhibidores de la glicoproteína IIb/IIIa se asocian con una reperfusión tisular más profunda luego de la angioplastia primaria.


Background The efficacy of primary angioplasty is limited due to the fact that a considerable number of patients do not achieve adequate levels of myocardial tissue perfusion. The degree of reperfusion depends on multiple clinical, angiographic and therapeutic factors. Objectives To identify the independent factors associated with the absence of myocardial tissue reperfusion after primary angioplasty. Material and Methods A total of 140 patients included in the Protection of Distal Embolization in High-Risk Patients with Acute ST-Segment Elevation Myocardial Infarction Trial (PREMIAR) were analyzed. This study evaluated the use of filter distal protection device during angioplasty in patients with acute STsegment elevation myocardial infarction at high risk of thrombosis (only including baseline TIMI grade 0-2 flow). The primary end point of the study was the rate of complete ST-segment resolution at 60 minutes, defined as ≥ 70% recovery compared with baseline during continuous ST-segment monitoring. A model of logistic regression was developed to identify independent predictors. Results Complete resolution of ST-segment deviation 60 minutes after angioplasty was observed in 82 patients (63%), while 53 patients (37%) presented partial ST-segment resolution which was associated with rates of mortality, reinfarction and/or heart failure at 30 days of 8.5% and 18.9%, respectively (p=0.07). The variables associated with absence of adequate myocardial tissue reperfusion were anterior infarction (79% versus 33%; p=0.001), higher heart rate (81±20 versus 70±15; p=0.001) and history of current smoking (25% versus 51%; p=0.002), compared to optimal tissue reperfusion. In addition, there was a trend towards greater prevalence of diabetes (26% versus 16%; p=0.13), longer time interval from the onset of symptoms to angioplasty (minutes) (217±167 versus 182±134; p=0.19) and Killip class >1 (30% versus 17%; p=0.07), respectively. Multivariate analysis demonstrated that anterior myocardial infarction was associated with absence of complete reperfusion (OR 8.22, 95% CI 3.67-18.4; p<0.001), while the use of glycoprotein IIb/IIIa inhibitors (OR 4.21, 95% CI 1.34-13.22; p=0.014) and current smoking (OR 3.84, 95% CI 1.58-9.50; p=0.003) correlated with complete reperfusion. Conclusions A considerable proportion of patients undergoing primary angioplasty do not achieve adequate myocardial tissue reperfusion. This phenomenon is associated with adverse outcomes. Anterior myocardial infarction correlates with less degree of tissue reperfusion. Conversely, current smoking and the use of glycoprotein IIb/IIIa inhibitors are associated with better tissue reperfusion after primary angioplasty.

20.
Rev. bras. cardiol. invasiva ; 17(2): 190-195, abr.-jun. 2009. tab
Article in Portuguese | LILACS | ID: lil-527891

ABSTRACT

Fundamentos: Lesões carotídeas estão presentes em 8% a 14% dos candidatos a cirurgia cardiovascular e aumentam o risco de acidente vascular cerebral perioperatório. Esse problema é particularmente importante em pacientes com doença coronária e/ou valvar grave que não são candidatos a procedimentos de revascularização em momentos diferentes. Avaliamos os resultados de uma estratégia híbrida de tratamento, na qual angioplastia carotídea e cirurgia cardiovascular foram realizadas de forma sequencial, com intervalo de algumas horas. Método: Foram tratadas lesões carotídeas > 70% em pacientes sintomáticos e > 80% nos assintomáticos. Ácido acetilsalicílico foi administrado antes da angioplastia carotídea e heparina, no momento do procedimento. Finalizada a intervenção percutânea, os pacientes foram transferidos para a sala de cirurgia para realização do procedimento cardiovascular. Clopidogrel foi administrado habitualmente 8 horas após o término da cirurgia...


Background: Carotid lesions are observed in 8% to 14% of cardiovascular surgery candidates and increase the risk of perioperative stroke. This is particularly important in patients with coronary disease and/or severe valve disease who are not candidate to revascularization procedures at different time points. We assessed the results of a hybrid strategy, where carotid angioplasty and cardiovascular surgery were performed sequentially with an interval of a few hours. Method: Carotid lesions > 70% in symptomatic patients and > 80% in asymptomatic patients were treated. Acetylsalicylic acid was administered prior to carotid stenting and heparin was administered at the time of the procedure. Once the percutaneous intervention was over, patients were transferred to the surgery room to carry out the cardiovascular procedure. Clopidogrel was administered 8 hours after the end of the surgery...


Subject(s)
Humans , Male , Female , Aged , Carotid Artery, Common/surgery , Carotid Artery, Common/pathology , Cardiovascular Surgical Procedures/methods , Cardiovascular Surgical Procedures , Stents
SELECTION OF CITATIONS