Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Type of study
Language
Year range
1.
Arch. cardiol. Méx ; 75(supl.3): 89-95, jul.-sep. 2005. ilus
Article in Spanish | LILACS | ID: lil-631927

ABSTRACT

La insuficiencia cardíaca avanzada es un problema de salud mundial a pesar de la terapéutica actual. Los pacientes con miocardiopatía dilatada (MCD) presentan muerte súbita por arritmias ventriculares en el 30% al 60%. Tanto el desflbrilador cardioverter automático implantable (DCAI) como la resincronización biventricular (RBV) en forma independiente han demostrado ser efectivos y seguros para lo que fueron destinados. Actualmente están en proceso varios estudios asociando estos dispositivos y los resultados son alentadores. El propósito del presente trabajo es reportar los primeros tres casos en México con ambos dispositivos, en uno se asoció un marcapaso con un DCAI y los otros dos con dispositivos que tienen ambas funciones. Se incluyeron tres hombres con edades de 63, 65 y 54 años, dos de ellos con historia de infarto, en clase funcional de la NYHA de II a IV, fracción de expulsión del ventrículo izquierdo (FEVI) de 25, 35 y 25%. Los tres mejoraron su clase funcional y la FEVI y dos han presentado descargas del DCAI.


Congestive heart failure (HF) remains a major and growing public health problem despite recent therapeutical developments. Thirty to sixty percent of patients with dilated cardiomyopathy (DCM) die suddenly from cardiac arrhythmias. Cardiac resynchronization therapy (CRT) and implantable cardioverter defibrillator (ICD) therapy are effective treatments for HF with a wide QRS and for ventricular arrhythmias respectively. Several trials are currently being performer to evaluate the cardiac resynchronization and implantable cardioverter defibrillator therapy with good results. The objective of this paper is to report the first three patients, in Mexico, that have received this combined therapy. In one patient, a three cameral pacemaker was associated with a unicameral ICD and the other two received a device with both functions. Patients were men, aged 63, 65, and 54 years, two of them with previous myocardial infarct and functional class II to IV of the NYHA. Left ventricular ejection fraction was of 25% in two patients and of 35% in the other. All patients improved their functional class and LVFE, two patients presented discharges of the ICD.


Subject(s)
Aged , Humans , Male , Middle Aged , Defibrillators, Implantable , Heart Failure/therapy , Pacemaker, Artificial , Combined Modality Therapy
SELECTION OF CITATIONS
SEARCH DETAIL