Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Iranian Cardiovascular Research Journal. 2011; 5 (2): 50-55
in English | IMEMR | ID: emr-162287

ABSTRACT

Tissue Doppler imaging is an echocardiographic useful method in the assessment of left ventricular myocardial function in the clinical condition. Pulsed Doppler interrogation measures the instantaneous velocities of the myocardium which passes through the sample volume during the cardiac cycle. The present study attempts to verify a computerized method to determine myocardial maximum and minimum velocities throughout the cardiac cycles using spectral pulsed-tissue Doppler imaging. The data of curves might be used to calculate myocardial physical and mechanical parameters throughout the cardiac cycle. Spectral pulsed-TDI was performed to evaluate longitudinal function in 23 healthy volunteers by using a sample volume placed in 170 left ventricular segments. The velocities were extracted automatically based on four common edge detection algorithms using Matlab software. Labeling of connected components in boundary of spectrum allowed comparing the methods. In addition to analysis of variance and t-test, linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the systolic and diastolic results of measurements before and after using the computed program. Comparison of the means of the four edge detection methods showed that there are statistically significant differences between methods [number of labels were 12 3 for Canny, 20 4 for Roberts, 31 4 for Sobel and 39 5 for Prewitt respectively, P<0.05]. There were not significant differences between measured velocities in the segments; before and after application of the Canny method. There was significant correlations [r=0.99 and r=0.96, P=0.01] at the base and mid segments, respectively with Bland-Altman analysis significant agreements between the measurements. It is concluded that the proposed method automatically extracts myocardial velocities using spectral pulsed images. Canny method showed relatively favorable results and seems to be a preferable option to extract velocities from the spectral images. Correlation study and Bland-Altman analysis confirmed a good agreement between the measurements


Subject(s)
Humans , Female , Male , Adult , Middle Aged , Myocardium , Blood Flow Velocity , Software
2.
IHJ-Iranian Heart Journal. 2011; 12 (3): 60-63
in English | IMEMR | ID: emr-127969

ABSTRACT

A 20-year-old man was referred to us for further evaluation due to infective endocarditis. He had mirror-image dextrocardia with visceral situs inversus. He had a history of dyspnea on exertion [NYHA class II] of several years' duration with no new onset symptoms. On physical examination, he had no peripheral stigmata of infective endocarditis. Laboratory examination showed a normal erythrocyte sedimentation rate with normal hemoglobin. Three separate sets of blood cultures obtained over a 24-hour period and cultures were negative in aerobic and anaerobic media. Transthoracic and transesophageal echocardiographic studies showed mirror-image dextrocardia with total situs inversus as well as accessory mitral valve tissue with chordal attachment to the posteromedial papillary muscle with no significant LVOT obstruction [Figs. 1,2] but resulting in mild to moderate aortic insufficiency [Fig.3]. There was also aneurysmal dilation of the membranous part of the interventricular septum with a residual pouch and no residual ventricular septal defect according to computational fluid dynamics and contrast studies [Fig 4]. There was no other concomitant abnormality. The patient was discharged in good physical condition

SELECTION OF CITATIONS
SEARCH DETAIL