Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Rev. Col. Bras. Cir ; 44(1): 41-45, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-842644

ABSTRACT

ABSTRACT Objective: to determine the ED90 (minimum effective dose in 90% of patients) of sugammadex for the reversal of rocuronium-induced moderate neuromuscular blockade (NMB) in patients with grade III obesity undergoing bariatric surgery. Methods: we conducted a prospective study with the biased coin up-and-down sequential design. We chosen the following doses: 2.0mg/Kg, 2.2mg/Kg, 2.4mg/Kg, 2.6mg/Kg, 2.8mg/Kg. The complete reversal of rocuronium-induced NMB considered a T4/T1 ratio ≥0.9 as measured by TOF. After induction of general anesthesia and calibration of the peripheral nerve stimulator and accelerometer, we injected rocuronium 0.6mg/kg. We administered propofol and remifentanil by continuous infusion, and intermittent boluses of rocuronium throughout the procedure. Results: we evaluated 31 patients, of whom 26 had displayed successful reversal of the NMB with sugammadex, and failure in five. The mean time to complete moderate NMB reversal was 213 seconds (172-300, median 25-75%). The ED90 of sugammadex calculated by regression was 2.39mg/kg, with a 95% confidence interval of 2.27-2.46 mg/kg. Conclusion: the ED90 of sugammadex in patients with grade III obesity or higher was 2.39mg/kg.


RESUMO Objetivos: determinar a ED90 (dose mínima eficaz em 90% dos pacientes) de sugamadex para a reversão de bloqueio neuromuscular (BNM) moderado induzido pelo rocurônio em pacientes com obesidade grau III submetidos à cirurgia bariátrica. Métodos: estudo prospectivo com o método de projeção sequencial para cima e para baixo da moeda enviesada. As seguintes doses foram escolhidas: 2,0mg/kg-1, 2,2mg/kg-1, 2,4mg/kg-1, 2,6mg/kg-1, 2,8mg/kg-1. A reversão completa de BNM induzido por rocurônio considerou uma relação T4/T1 ≥0,9 na medida do TOF. Após a indução da anestesia geral e calibração do estimulador de nervo periférico e acelerômetro, rocurônio 0,6mg/kg-1 foi injetado. Infusão contínua de propofol e remifentanil, e bolus intermitente de rocurônio foram injetados durante todo o procedimento. Resultados: trinta e um pacientes foram avaliados, 26 dos quais bem-sucedidos e cinco sem reversão completa do BNM moderado promovido pelo sugamadex. O tempo médio para completar reversão de BNM foi 213 segundos (172 a 300 segundos; mediana, 25-75%). O ED90 de sugamadex calculado pela regressão foi de 2,39mg/kg-1 com um intervalo de confiança de 95% (2,27 a 2,46mg/kg-1). Conclusão: o ED90 de sugamadex em pacientes com obesidade grau III ou superior foi 2,39mg/kg-1.


Subject(s)
Humans , Male , Female , Adult , Neuromuscular Nondepolarizing Agents/therapeutic use , Neuromuscular Blockade , gamma-Cyclodextrins/administration & dosage , Bariatric Surgery , Androstanols/therapeutic use , Obesity/surgery , Prospective Studies , Sugammadex , Rocuronium , Middle Aged
2.
Rev. bras. anestesiol ; 66(5): 451-455, Sept.-Oct. 2016. tab, graf
Article in English | LILACS | ID: lil-794806

ABSTRACT

Abstract Background and objectives: Decrease in body temperature is common during general and regional anesthesia. Forced-air warming intraoperative during cesarean section under spinal anesthesia seems not able to prevent it. The hypothesis considers that active warming before the intraoperative period avoids temperature loss during cesarean. Methods: Forty healthy pregnant patients undergoing elective cesarean section with spinal anesthesia received active warming from a thermal gown in the preoperative care unit 30 min before spinal anesthesia and during surgery (Go, n = 20), or no active warming at any time (Ct, n = 20). After induction of spinal anesthesia, the thermal gown was replaced over the chest and upper limbs and maintained throughout study. Room temperature, hemoglobin saturation, heart rate, arterial pressure, and tympanic body temperature were registered 30 min before (baseline) spinal anesthesia, right after it (time zero) and every 15 min thereafter. Results: There was no difference for temperature at baseline, but they were significant throughout the study (p < 0.0001; repeated measure ANCOVA). Tympanic temperature baseline was 36.6 ± 0.3 °C, measured 36.5 ± 0.3 °C at time zero and reached 36.1 ± 0.2 °C for gown group, while control group had baseline temperature of 36.4 ± 0.4 °C, measured 36.3 ± 0.3 °C at time zero and reached 35.4 ± 0.4 °C (F = 32.53; 95% CI 0.45-0.86; p < 0.001). Hemodynamics did not differ throughout the study for both groups of patients. Conclusion: Active warming 30 min before spinal anesthesia and during surgery prevented a fall in body temperature in full-term pregnant women during elective cesarean delivery.


Resumo Justificativa e objetivos: A redução da temperatura corporal é comum durante a anestesia tanto geral quanto regional. O sistema de ar forçado aquecido no intraoperatório durante a cesariana sob anestesia peridural não parece conseguir impedi-la. A hipótese considera que o aquecimento ativo antes do período intraoperatório evita a perda de temperatura durante a cesariana. Métodos: Quarenta pacientes grávidas, saudáveis, submetidas à cesariana eletiva com anestesia espinal receberam aquecimento ativo de um avental térmico na unidade de cuidados pré-operatórios 30 minutos antes da anestesia e durante a cirurgia (Go, n = 20) ou nenhum aquecimento ativo a qualquer momento (Ct, n = 20). Após a indução da anestesia espinhal, o avental térmico foi colocado sobre o tórax e os membros superiores e mantido durante o estudo. Temperatura ambiente, saturação de hemoglobina, frequência cardíaca, pressão arterial e temperatura corporal timpânica foram registradas 30 minutos antes (fase basal) da anestesia espinhal, logo após a anestesia (tempo zero) e a cada 15 minutos subsequentemente. Resultados: Não houve diferença de temperatura na fase basal, mas as diferenças foram significativas ao longo do estudo (p < 0,0001; Ancova de medida repetida). A temperatura timpânica na fase basal foi de 36,6 ± 0,3 °C, mediu 36,5 ± 0,3 °C no tempo zero e atingiu 36,1 ± 0,2 °C no grupo avental, enquanto a temperatura basal do grupo controle foi de 36,4 ± 0,4 °C, mediu 36,3 ± 0,3 °C no tempo zero e atingiu 35,4 ± 0,4 °C (F = 32,53; IC de 95% 0,45-0,86, p < 0,001). A hemodinâmica não diferiu ao longo do estudo em ambos os grupos de pacientes. Conclusão: O aquecimento ativo 30 minutos antes da anestesia espinhal e durante a cirurgia evitou a queda da temperatura corporal em mulheres grávidas a termo durante a cesariana eletiva.


Subject(s)
Humans , Female , Pregnancy , Adult , Body Temperature , Cesarean Section/methods , Rewarming/instrumentation , Rewarming/methods , Hypothermia/prevention & control , Intraoperative Complications/prevention & control , Tympanic Membrane , Elective Surgical Procedures , Anesthesia, Epidural , Anesthesia, Obstetrical , Anesthesia, Spinal
3.
Rev. bras. anestesiol ; 64(3): 164-168, May-Jun/2014. tab, graf
Article in English | LILACS | ID: lil-715653

ABSTRACT

Background and objectives: Few investigations have addressed the safety of oxygen from concentrators for use in anesthesia in association with nitrous oxide. This study evaluated the percent of oxygen from a concentrator in association with nitrous oxide in a semi-closed rebreathing circuit. Methods: Adult patients undergoing low risk surgery were randomly allocated into two groups, receiving a fresh gas flow of oxygen from concentrators (O293) or of oxygen from concentrators and nitrous oxide (O293N2O). The fraction of inspired oxygen and the percentage of oxygen from fresh gas flow were measured every 10 min. The ratio of FiO2/oxygen concentration delivered was compared at various time intervals and between the groups. Results: Thirty patients were studied in each group. There was no difference in oxygen from concentrators over time for both groups, but there was a significant improvement in the FiO2 (p < 0.001) for O293 group while a significant decline (p < 0.001) for O293N2O. The FiO2/oxygen ratio varied in both groups, reaching a plateau in the O293 group. Pulse oximetry did not fall below 98.5% in either group. Conclusion: The FiO2 in the mixture of O293 and nitrous oxide fell during the observation period although oxygen saturation was higher than 98.5% throughout the study. Concentrators can be considered a stable source of oxygen for use during short anesthetic procedures, either pure or in association with nitrous oxide at 50:50 volume. .


Justificativa e objetivos: poucas pesquisas abordaram a segurança do oxigênio a partir de concentradores para uso em anestesia em associação com óxido nitroso. Este estudo avaliou a porcentagem de oxigênio a partir de um concentrador em associação com óxido nitroso em um circuito de reinalação semifechado. Métodos: pacientes adultos submetidos à cirurgia de baixo risco foram alocados aleatoriamente em dois grupos e receberam um fluxo de gases frescos de concentradores de oxigênio (O293) ou de concentradores de oxigênio e óxido nitroso (O293N2O). A fração inspirada de oxigênio e a porcentagem do fluxo de gases frescos de oxigênio foram medidas a cada 10 minutos. O razão da concentração liberada de FiO2/oxigênio foi comparada em diferentes intervalos de tempo e entre os grupos. Resultados: foram avaliados em cada grupo 30 pacientes. Não houve diferença em oxigênio a partir dos concentradores ao longo do tempo para ambos os grupos, mas houve uma melhora significativa da FiO2 (p < 0,001) no grupo O293, enquanto houve uma queda significativa (p < 0,001) no grupo O293N2O. A razão FiO2/oxigênio variou em ambos os grupos e atingiu um patamar no grupo O293. A oximetria de pulso não caiu abaixo de 98,5% em ambos os grupos. Conclusão: a FiO2 na mistura de O293 e óxido nitroso caiu durante o período de observação, embora a saturação de oxigênio tenha ficado acima de 98,5% durante todo o estudo. Os concentradores podem ser considerados uma fonte estável de oxigênio para uso durante procedimentos anestésicos de curta duração, tanto puro quanto em associação com óxido nitroso em volume de 50:50. .


Justificación y objetivos: pocas investigaciones han abordado la seguridad del oxígeno a partir de concentradores para su uso en anestesia en asociación con el óxido nitroso. Este estudio evaluó el porcentaje de oxígeno de un concentrador en asociación con el óxido nitroso en un circuito de reinhalación semicerrado. Métodos: pacientes adultos sometidos a cirugía de bajo riesgo fueron asignados aleatoriamente en 2 grupos, para recibir un flujo de gases frescos de concentradores de oxígeno (O293) o de concentradores de oxígeno y óxido nitroso (O293NO). La fracción inspirada de oxígeno y el porcentaje del flujo de gases frescos de oxígeno fueron medidos cada 10 min. La relación concentración liberada de FiO2/oxígeno fue comparada en diferentes intervalos de tiempo y entre los grupos. Resultados: treinta pacientes fueron evaluados en cada grupo. No hubo diferencia en el oxígeno de los concentradores a lo largo del tiempo para ambos grupos, pero sí hubo una mejoría significativa en la FiO2 (p < 0,001) en el grupo O293, mientras que hubo una caída significativa (p < 0,001) en el grupo O293NO. La relación FiO2/oxígeno varió en ambos grupos, alcanzando una meseta en el grupo O293. La oximetría de pulso no descendió por debajo del 98,5% en ningún grupo. Conclusión: la FiO2 en la mezcla de O293 y óxido nitroso cayó durante el período de observación, aunque la saturación de oxígeno quedó por encima de un 98,5% durante todo el estudio. Los concentradores pueden ser considerados una fuente estable de oxígeno para uso durante procedimientos anestésicos de corta duración, tanto puro como en asociación con el óxido nitroso en volumen de 50:50. .


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Young Adult , Anesthetics, Inhalation/administration & dosage , Nitrous Oxide/administration & dosage , Oxygen Inhalation Therapy/methods , Oxygen/administration & dosage , Anesthesia, Closed-Circuit/instrumentation , Anesthesia, Closed-Circuit/methods , Anesthesia/methods , Anesthesiology/instrumentation , Anesthesiology/methods , Oximetry , Oxygen/metabolism , Time Factors
4.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 35(4): 364-368, Oct-Dec. 2013. tab
Article in English | LILACS | ID: lil-697331

ABSTRACT

Objective: This study evaluated the relationship between psychological coping mechanisms and symptoms of anxiety and depression in the preoperative and postoperative periods in relation to the intensity of postoperative pain among patients undergoing breast cancer surgery. Methods: Female patients who were scheduled to receive immediate surgical treatment for breast cancer were invited to participate, and answered the following questionnaires: The Hospital Anxiety and Depression Scale (HADS), the Self Report Questionnaire (SRQ-20), the Coping Strategies Questionnaire (CSQ), and the visual analogue scale (VAS). Results: Of the 139 patients, 122 (87.8%) had an aggressive procedure. Eighty-five patients (61.2%) had a history of preoperative pain while 54 (38.7%) had not. There was no difference in VAS scores between patients subjected to aggressive or non-aggressive surgery. Only the CSQ subscale catastrophizing showed correlation with VAS at 24 hours and with HADS/D postoperatively. The HADS scores indicated both anxiety and depression, but did not distinguish patients subjected to aggressive or non-aggressive surgery. Conclusions: The majority of patients did not exhibit depression and anxiety. Coping mechanisms and pain in the preoperative period did not have a strong predictive value for additional postoperative pain, but those with a higher anxiety score had greater pain. .


Subject(s)
Adolescent , Adult , Aged , Female , Humans , Middle Aged , Young Adult , Adaptation, Psychological , Breast Neoplasms/psychology , Pain, Postoperative/psychology , Postoperative Care , Preoperative Care , Anxiety/etiology , Breast Neoplasms/surgery , Depression/etiology , Pain Measurement , Surveys and Questionnaires
5.
Rev. bras. anestesiol ; 59(6): 665-673, nov.-dez. 2009. tab
Article in Portuguese | LILACS | ID: lil-533878

ABSTRACT

Justificativa e objetivos: O bloqueio de plexo braquial é técnica anestésica utilizada para procedimentos em membros superiores. O plexo braquial é território potencial para absorção de anestésicos locais. Estudos dos estereoisômeros da bupivacaína vêm demonstrando menor potencial de toxicidade da fração levógira (levobupivacaína) sobre o sistema cardiovascular. Porém, é discutida a eficácia anestésica (bloqueio sensitivo e motor) da levobupivacaína em anestesia do neuroeixo. Este estudo visa demonstrar a eficácia anestésica da levobupivacaína, comparandoa com a bupivacaína racêmica em bloqueio de plexo...


Background and objetives: Brachial plexus block is used in surgical procedures of the upper limbs. The brachial plexus is a potential territory for absorption of local anesthetics. Studies on bupivacaine isomers have shown reduced cardiovascular toxicity of its levorotatory form (levobupivacaine). However, the anesthetic efficacy (sensorial and motor blockades) of levobupivacaine in neuroaxis blocks has been debated. The objective of this study was to demonstrate the anesthetic efficacy of levobupivacaine in brachial plexus block, using the perivascular subclavian approach, by comparing...


Justificativa y objetivos: El bloqueo de plexo braquial es la técnica anestésica utilizada para procedimientos en miembros superiores. El plexo braquial es el territorio potencial para la absorción de anestésicos locales. Estudios de los estereoisómeros de la bupivacaína han venido demostrando un menor potencial de toxicidad de la fracción levógira (levobupivacaína), sobre el sistema cardiovascular. Sin embargo, se discute la eficacia anestésica (bloqueo sensitivo y motor), de la levobupivacaína en anestesia del neuro eje. Este estudio pretende demostrar la eficacia anestésica de la levobupivacaína...


Subject(s)
Adult , Female , Humans , Male , Anesthetics, Local , Brachial Plexus , Bupivacaine , Nerve Block , Anesthetics, Local/administration & dosage , Bupivacaine/administration & dosage , Bupivacaine/analogs & derivatives
6.
Rev. bras. anestesiol ; 59(2): 177-186, mar.-abr. 2009. graf, tab
Article in English, Portuguese | LILACS | ID: lil-511595

ABSTRACT

JUSTIFICATIVAS E OBJETIVOS: A manobra de recrutamento alveolar (MRA) é indicada no tratamento de atelectasias intraoperatórias. O objetivo do presente estudo foi comparar duas técnicas de MRA por meio da resposta da relação PaO2/FiO2 e da soma [PaO2+PaCO2], em pacientes obesos grau III. MÉTODO: Estudo prospectivo aberto em pacientes adultos, obesos grau III, submetidos a procedimento cirúrgico bariátrico em ventilação controlada a volume, pressão positiva no final da expiração (PEEP) de 5 cmH2O e divididos em três grupos: G CONT: PEEP de 5 cmH2O; G MRA10/15/20 após sutura da aponeurose: aumento progressivo da PEEP para 10,15 e 20 cmH2O, pausa de 40 segundos e manutenção de cada valor da PEEP por 2 minutos; G MRA30: após sutura da aponeurose: aumento súbito da PEEP para 30 cmH2O, 40 segundos de pausa e manutenção da PEEP em 30 cmH2O por dois minutos. Foram analisadas as variáveis frequência cardíaca, pressão arterial média, sistólica, diastólica, pressão média das vias aéreas (P MVA) e de platô (P PLAT), pressão arterial de oxigênio (PaO2), pressão arterial de CO2 (PaCO2), relação PaO2/FiO2 (fração inspiratória de oxigênio) e soma [PaO2+PaCO2]. RESULTADOS: As variáveis que apresentaram diferença estatística significativa entre os três grupos foram: P PLAT, P MVA, PaO2, relação PaO2/FiO2 e soma [PaO2+PaCO2] (p < 0,0001). Na comparação dos grupos dois a dois, verificou-se diferença estatística significativa para as variáveis P PLAT e P MVA: G CONT X G MRA10/15/20 e G CONT X G MRA30 e para as variáveis relação PaO2/FiO2 e soma [PaO2+PaCO2]: G CONT X G MRA30. CONCLUSÕES: A técnica de MRA com aumento súbito da PEEP para 30 cm H2O mostrou a melhor resposta da relação PaO2/FiO2.


BACKGROUND AND METHDS: Alveolar recruitment maneuver (ARM) is indicated in the treatment of intraoperative atelectasis. The objective of the present study was to compare two techniques of ARM using the response of the PaO2/FiO2 ratio and [PaO2 + PaCO2] in patients with grade III obesity. METHODS: This was an open prospective study with adult patients with grade III obesity who underwent bariatric surgery under volume-controlled mechanical ventilation with positive end-expiratory pressure (PEEP) of 5 cmH2O, divided in three groups: G CONT: PEEP of 5 cmH2O; G ARM10/15/20 after suture of the aponeurosis: progressive increase in PEEP to 10, 15, and 20 cmH2O with a 40-second pause and maintaining each level of PEEP for 2 minutes; and G ARM30 after suture of the aponeurosis: sudden increase in PEEP to 30 cmH2O with a 40-second pause and maintaining a PEEP of 30 for 2 minutes. Heart rate, mean arterial pressure, systolic and diastolic blood pressure, mean (P AW) and plateau (P PLAT) airways pressure, partial pressure of oxygen (PaO2), partial pressure of carbon dioxide (PaCO2), PaO2/FiO2 ratio (inspired fraction of oxygen), and [PaO2 + PaCO2] were analyzed. RESULTS: The following parameters showed statistically significant differences among the study groups: P PLAT, P AW, PaO2, PaO2/FiO2 ratio, and [PaO2 + PaCO2] (p < 0.0001). Comparing the groups two by two, the following parameters showed statistically significant differences: for P PLAT and P AW: G CONT x G2ARM10/15/20 and G CONT x G ARM30; and for PaO2/FiO2 ratio and [PaO2 + PaCO2]: G CONT x G ARM30. CONCLUSIONS: Alveolar recruitment maneuver with sudden increase of PEEP to 30 cmH2O showed a better response of the PaO2/FiO2 ratio.


JUSTIFICATIVAS Y OBJETIVOS: La maniobra de reclutamiento alveolar (MRA) se indica en el tratamiento de atelectasias intraoperatorias. El objetivo del presente estudio fue comparar dos técnicas de MRA por medio de la respuesta de la relación PaO2/FiO2 y de la suma [PaO2+PaCO2], en pacientes obesos con grado III. MÉTODO: Estudio prospectivo abierto en pacientes adultos, obesos grado III, sometidos a procedimiento quirúrgico bariátrico en ventilación controlada a volumen, presión positiva al final de la expiración (PEEP) de 5 cmH2O y divididos en tres grupos: G CONTROL: PEEP de 5 cmH2O; G MRA10/15/20 después de la sutura de la aponeurosis: aumento progresivo de la PEEP para 10,15 y 20 cmH2O, pausa de 40 segundos y mantenimiento de cada valor de la PEEP por 2 minutos; G MRA30: después de la sutura de la aponeurosis: aumento súbito de la PEEP para 30 cmH2O, 40 segundos de pausa y mantenimiento de la PEEP en 30 cmH2O por dos minutos. Se analizaron las variables frecuencia cardíaca, presión arterial promedio, sistólica, diastólica, presión promedio de las vías aéreas (P MVA) y de meseta (P PLAT), presión arterial de oxígeno (PaO2), presión arterial de CO2 (PaCO2), relación PaO2/FiO2 (fracción inspiratoria de oxígeno) y suma [PaO2+PaCO2]. RESULTADOS: Las variables que presentaron una diferencia estadística significativa entre los tres grupos fueron: P PLAT, P MVA, PaO2, relación PaO2/FiO2 y suma [PaO2+PaCO2] (p < 0,0001). En la comparación de los grupos dos a dos, se verificó una diferencia estadística significativa para las variables P PLAT y P MVA: G CONTROL X G MRA10/15/20 y G CONTROL X G MRA30 y para las variables relación PaO2/FiO2 y suma [PaO2+PaCO2]: G CONTROL X G MRA30. CONCLUSIONES: La técnica de MRA con aumento súbito de la PEEP para 30 cm H2O mostró la mejor respuesta de la relación PaO2/FiO2.


Subject(s)
Humans , Adult , Bariatric Surgery/adverse effects , Positive-Pressure Respiration , Pulmonary Atelectasis
7.
Rev. bras. anestesiol ; 59(1): 37-45, jan.-fev. 2009. tab, ilus
Article in English, Portuguese | LILACS | ID: lil-505825

ABSTRACT

JUSTIFICATIVA E OBJETIVOS: O cardiodesfibrilador implantável (CDI) foi introduzido na prática clínica em 1980 e é considerado o tratamento-padrão para indivíduos sob risco de desenvolverem disritmias ventriculares fatais. Com o intuito de garantir funcionamento adequado do cardiodesfibrilador, a energia necessária para o término da taquicardia ventricular ou da fibrilação ventricular deve ser determinada durante o implante, sendo esse procedimento chamado de teste do limiar de desfibrilação. Para a realização do teste é necessário que seja feita indução de fibrilação ventricular, para que o aparelho possa identificar o ritmo cardíaco e tratá-lo. O objetivo deste estudo foi verificar a ocorrência de disfunção cognitiva 24 horas após o implante de cardiodesfibrilador. MÉTODO: Foi selecionada uma amostra consecutiva de 30 pacientes com indicação de colocação de cardiodesfibrilador implantável (CDI) e 30 pacientes com indicação de implante de marca-passo (MP). Os pacientes foram avaliados nos seguintes momentos: 24 horas antes da colocação do CDI ou MP com ficha de avaliação pré-anestésica, Mini Exame do Estado Mental (MEEM) e Confusion Assessment Method (CAM). Durante o implante do CDI ou MP foram medidas as variáveis: número de paradas cardíacas e tempo total de parada cardíaca. Vinte e quatro horas após colocação do CDI ou MP, foram avaliadas as variáveis: MEEM e CAM. RESULTADOS: O teste de Fisher comprovou não haver diferença da freqüência de escores alterados do MEEM e do CAM entre os grupos antes e depois dos implantes. O tempo médio de PCR foi 7,06 segundos, com máximos e mínimos de 15,1 e 4,7 segundos. CONCLUSÕES: A indução de parada cardíaca durante o teste do limiar de desfibrilação não levou à disfunção cognitiva 24 horas após o implante de cardiodesfibrilador.


JUSTIFICATIVA Y OBJETIVOS: El desfibrilador cardiaco implantable (DCI) fue introducido en la práctica clínica en el 1980 y se considera el tratamiento estándar para individuos bajo el riesgo de desarrollar arritmias ventriculares fatales. Con el interés de garantizar el funcionamiento adecuado del desfibrilador cardiaco, la energía necesaria para el término de la taquicardia ventricular o de la fibrilación ventricular, debe ser determinada durante el implante, siendo este procedimiento llamado test del límite de desfibrilación. Para la realización del test es necesario que se haga la inducción de la fibrilación ventricular, para que el aparato pueda identificar el ritmo cardíaco y tratarlo. El objetivo de este estudio fue verificar la incidencia de disfunción cognitiva 24 horas después del implante del desfibrilador cardiaco. MÉTODO: Se seleccionó una muestra consecutiva de 30 pacientes con indicación de colocación de desfibrilador cardiaco implantable (DCI) y 30 pacientes con indicación de implante de marca-paso (MP). Los pacientes fueron evaluados en los siguientes momentos: 24 horas antes de la colocación del DCI o MP con ficha de evaluación preanestésica, Mini-Examen del Estado Mental (MEEM) y Confusion Assessment Method (CAM). Durante el implante del DCI o MP fueron medidas las variables: número de paradas cardíacas y tiempo total de parada cardíaca. Veinte y cuatro horas después de la colocación del DCI o MP, se evaluaron las variables: MEEM y CAM. RESULTADOS: El test de Fisher mostró que no había diferencia de la frecuencia de puntuaciones alteradas del MEEM y del CAM entre los grupos antes y después de los implantes. El tiempo promedio de PCR 7,06, con máximos y mínimos de 15,1 y 4,7 segundos. CONCLUSIONES: La inducción de parada cardíaca durante el test del límite de desfibrilación, no conllevó a la disfunción cognitiva veinte y cuatro horas después del implante del desfibrilador cardiaco.


BACKGROUND AND OBJECTIVES: Implantable cardioverter-defibrillators (ICD) were introduced in clinical practice in 1980 and they are considered the standard treatment for individuals at risk for fatal ventricular arrhythmias. To ensure proper working conditions, the energy necessary to interrupt ventricular tachycardia or ventricular fibrillation should be determined during implantation by a test called defibrillation threshold. For this test, it is necessary to induce ventricular fibrillation, which should be identified and treated by the device. The objective of the present study was to determine the frequency of cognitive dysfunction 24 hours after the implantation of a cardioverter-defibrillator. METHODS: Thirty consecutive patients with indication of cardioverter-defibrillator (ICD) placement and 30 patients with indication of implantable pacemaker (PM) were enrolled in this study. Patients were evaluated at the following moments: 24 hours before placement of the ICD or PM with a pre-anesthetic evaluation form, Mini Mental State Examination (MMSE), and Confusion Assessment Method (CAM); during implantation of the ICD or PM, the following parameters were determined: number of cardiac arrests and total time of cardiac arrest. Twenty-four hours after placement of the device, the following parameters were evaluated: MMSE and CAM. RESULTS: Differences in the frequency of altered MMSE and CAM scores between both groups before and after implantation were not detected by the Fisher Exact test. The mean time of cardiac arrest was 7.06 seconds, with a maximal of 15.1 and minimal of 4.7 seconds. CONCLUSIONS: Induction of cardiac arrest during defibrillation threshold testing did not cause cognitive dysfunction 24 hours after implantation of the cardioverter-defibrillator.


Subject(s)
Humans , Defibrillators, Implantable/adverse effects , Heart Arrest, Induced , Brain Ischemia/complications , Pacemaker, Artificial/adverse effects , Thoracic Surgery , Cognition Disorders/etiology
SELECTION OF CITATIONS
SEARCH DETAIL