Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Rev. latinoam. enferm ; 16(3): 362-367, May-June 2008. tab
Article in English, Spanish, Portuguese | LILACS, BDENF | ID: lil-488529

ABSTRACT

A randomized, controlled study was implemented to verify reasons to release and adverse events related to the use of peripheral intravenous catheters in children, according to the dressing regimens The sample was set at 150 peripheral intravenous catheters, randomly assigned to three groups: sterile gauze dressings, sterilized transparent film dressings, and non sterile hypoallergenic adhesive tape. The data was collected after consent had been obtained by the Ethics Committee, including children who had been submitted to catheterization with Teflon® over the needle catheters. Statistical tests were performed by applying the Pearson Chi-square test, significance level set at p < 0.05. The results showed that dressing regimens influenced the reasons for catheter removal and occurrence of adverse events, mainly due to infiltration (55.3 percent). The Sterile gauze showed the best performance (p=0.002) in comparison with the other studied groups, once 40.0 percent of the catheters were removed by release from treatment.


Se trata de un estudio aleatorio y controlado que tuvo como objetivo identificar los motivos de retirada y los eventos adversos relacionados al uso de catéteres intravenosos periféricos en niños según el tipo de curativo. La muestra fue constituida por 150 catéteres distribuidos en tres grupos, compuestos por: curativo con gasa estéril, película transparente y fijación con cinta adhesiva hipoalergénica no estéril. La recolección de datos ocurrió después de la aprobación del merito ético, incluyéndose en el estudio niños sometidos a la punción intravenosa periférica, con catéteres de Teflón® fuera de la aguja. Para analizar la correlación entre las variables fue utilizada la prueba de Chi-cuadrado de Pearson, siendo considerados significativos los valores de pd"0,05. Los resultados evidenciaron que los curativos influenciaron los motivos de retirada del catéter y la ocurrencia de eventos adversos, destacándose la infiltración (55,3 por ciento). El curativo con gasa, en comparación con los otros grupos estudiados, presentó una menor proporción de eventos adversos (p= 0,002), siendo que 40,0 por ciento de los catéteres fueron retirados por el alta del tratamiento.


Estudo randomizado e controlado que objetivou identificar motivos de retirada e eventos adversos relacionados ao uso de cateteres intravenosos periféricos em crianças segundo tipo de curativo. A amostra foi ajustada em 150 cateteres distribuídos em três grupos, compostos por curativo com gaze estéril ou película transparente e fixação com fita adesiva hipoalergênica não estéril. A coleta de dados ocorreu após aprovação do mérito ético, incluindo-se no estudo crianças submetidas à punção intravenosa periférica, com cateteres fora da agulha de Teflon®. Para análise de correlação entre variáveis foi utilizado teste do Qui-quadrado de Pearson, sendo considerados significantes valores de p < 0,05. Os resultados evidenciaram que os curativos influenciaram os motivos de retirada do cateter e a ocorrência de eventos adversos, destacando-se a infiltração (55,3 por cento). O curativo com gaze em comparação com os outros grupos estudados apresentou menor proporção de eventos adversos (p=0,002), sendo 40,0 por cento dos cateteres retirados por alta do tratamento.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Bandages , Catheterization, Peripheral
2.
Rev. latinoam. enferm ; 13(3): 291-298, maio-jun. 2005. tab
Article in Portuguese | LILACS, BDENF | ID: lil-405419

ABSTRACT

Estudo prospectivo, randomizado e controlado, que verificou a influência de três tipos de curativos, sobre o tempo de permanência de cateteres venosos periféricos (CVP) em crianças. Os grupos de estudo foram compostos por curativos com gaze estéril (GE 1), película transparente estéril (GE 2) e fita adesiva hipoalergênica (GC). Foram selecionadas variáveis para o controle de características referentes às crianças, profissionais executantes dos procedimentos e terapia intravenosa. Compuseram os grupos 150 CVP, instalados em 68 crianças, predominantemente pré-escolares, sexo masculino, cor da pele parda, eutróficas com patologias do sistema gastrointestinal. A maioria dos CVP foi instalada por auxiliares de enfermagem, em veias do arco dorsal da mão. Verificamos que o tipo de curativo influenciou significantemente (p=0,022) o tempo médio de permanência dos CVP estudados: GE 1 (46,12 horas), GE 2 (29,53 horas) e GC (38,18 horas), e o curativo com gaze estéril manteve o cateter por mais tempo.


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Bandages , Catheterization, Peripheral/methods , Pediatric Nursing/methods , Infusions, Intravenous , Prospective Studies
3.
Säo Paulo; s.n; 2003. [154] p. ilus, tab.
Thesis in Portuguese | LILACS | ID: lil-336688

ABSTRACT

Estudo experimental sobre o motivo da retirada e tempo de permanência de cateteres venosos periféricos, segundo três tipos de curativos. As variáveis experimentais foram compostas por curativo com gaze estéril, que constituiu o grupo experimental 1, e curativo com película transparente estéril, denominado grupo experimental 2. O curativo convencional com fita adesiva compôs o grupo controle. Obtivemos nos três grupos de estudo, 150 cateteres venosos periféricos implantados em 68 crianças com idade entre zero e 12 anos, internadas em uma unidade de cirurgia pediátrica de um hospital universitário da cidade de São Paulo. Foram selecionadas variáveis para homogeneização dos grupos de estudo, tais como, idade, grau de nutrição, cor da pele, sexo e diagnóstico médico das crianças; categoria profissional do executante da punção venosa periférica e do curativo; calibre, local de inserção, fixação, imobilização, forma e soluções utilizadas para manutenção do cateter. Para a análise estatística foram aplicados os testes do Qui-quadrado, de análise de variância (ANOVA) e de Kruskal-Wallis, fixando-se em 5 por cento o nível para a rejeição da hipótese de nulidade. Os resultados mostraram distribuição não significante das variáveis de homogeneização, nos três grupos de estudo, com exceção da categoria profissional do executante da punção venosa (p = 0,029). As crianças que participaram do estudo eram predominantemente pré-escolares, eutróficas, pardas, do sexo masculino, com patologias do sistema gastrointestinal que necessitavam de intervenção cirúrgica. As auxiliares de enfermagem foram as profissionais que mais executaram punções venosas e curativos de cateter venoso periférico. Quanto aos cateteres de Teflon utilizados, a maioria foi de calibre 24 G, inseridos nas veias do arco dorsal da mão, fixados e imobilizados nos membros superiores, mantidos principalmente de modo contínuo para infusão de solução...(au)


Subject(s)
Catheterization, Peripheral , Occlusive Dressings , Pediatric Nursing