1.
Chinese Medical Equipment Journal ; (6): 51-53, 2017.
Article in Chinese | WPRIM | ID: wpr-608106

ABSTRACT

Objective To modify the existed transfer trolley for collection and distribution so as to enhance cleaning and disinfection.Methods The existed transfer trolley was added with an intake pipe,a spray nozzle,a drilled divider,a drainage pipe and etc for perfusion rinse,and equipped with auxiliary mechanisms such as a protective support and preserver.Omnidirectional cleaning and disinfection of the trolley were executed by the intake pipe,nozzle and high-pressure irrigation machine.Results The trolley prevented the disinfection solution from spitting,ensured the safety of the staff and environment,and had the qualified rate of disinfection being 100%.Conclusion The modified transfer trolley gains advantages in environmental protection,energy saving and practicability,and thus is worthy promoting clinically.

2.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-592580

ABSTRACT

The general situation of sudden public events is introduced.Considering the characteristics and phases of massive earthquake disaster,the system of emergency medical supplies for sudden public events is set up in terms of storing and managing the emergency medical supplies by reasonable determining the amount of all kinds of emergency medical supplies such as goods reserve,market reserve,production & technology capacity reserve,etc.

3.
Chinese Medical Equipment Journal ; (6)2004.
Article in Chinese | WPRIM | ID: wpr-592390

ABSTRACT

Objective To explore problems of chemical indicative cards and adhesive tapes in the disinfection,and find out some measures for improving the sterilizing effect of the pressure steam sterilizer.Methods 100 stoves of time with various package,dressing and storage tank were disinfected by pulse pressure steam sterilizer and chemical indicative cards of 3M1250 pressure steam sterilizing package at the same pressure,time and temperature.All test wraps were examined and the real conditions were recorded after the sterilization.Results The discoloration of chemical indicative cards in 10 test wraps was not standard before the measures were taken.While after that,it didn't occur again.Conclusion The nonstandard discoloration of chemical indicative cards of 3M1250 pressure steam sterilizer is influenced by condensed water of steam during the steam sterilization.In order to make the chemical indicative cards change into standard black,the accurate using of chemical indicative cards,the standard stuff package and correct using of disinfector are required.

4.
Chinese Medical Equipment Journal ; (6)2003.
Article in Chinese | WPRIM | ID: wpr-590375

ABSTRACT

Operation rules of sterilizing are put forward.Responsible persons with working licenses are selected.The cleanout,packing,loading of pre-sterilized goods are standardized.Sterilizing effects(physical monitoring,chemical monitoring,biological monitoring,B-D test) are inspected.Requirements in maintenance and metrology test are raised.The content and methods for quality control of sterilized goods by using decontamination device are introduced systematically.It is instructive to enhance decontamination quality and lower infection rate in hospitals.

5.
Chinese Medical Equipment Journal ; (6)1993.
Article in Chinese | WPRIM | ID: wpr-586519

ABSTRACT

This paper discusses how to strengthen the quality management of low-cost medical consumables in such aspects as purchase,check and acceptance,deposit and provision of low-cost consumables.

6.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-594168

ABSTRACT

On the basis of the system requirement on medical oxygen supply in modern hospital, from the aspects of rigorous installation, ensuring logical course environment, following related technological standard and enhancing personnel training, the whole quality course management is put up. It is indicate that proper equipment and quality control in evary link are the quarantee of clinical service.