Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. bras. cineantropom. desempenho hum ; 17(3): 300-308, May.-June 2015. graf
Article in English | LILACS | ID: lil-766343

ABSTRACT

Abstract This study aimed to compare the perceived subjective exertion (PSE) and total load lifted in resistance exercises performed on stable platforms (SP) and unstable platforms (UP). Participants were 20 men (24.6 ± 3.4 years, 179 ± 0.1 cm, 80.6 ± 9.1 kg and 11.8 ± 3.4% fat). Each subject performed a 15 maximum repetition test in half squat exercises (soil and balance discs), pronated barbell row (soil and bosu) and biceps curl (soil and balance discs) in both conditions. PSE was measured using the OMNI-RES scale and the load lifted value (kg). To verify the normality of data, the Shapiro-Wilk test was used. Possible differences related to loads and PSE on the platforms were performed by the paired t test. Significance level of p <0.05 was adopted. No significant differences between PSE values on SP and UP were respectively observed in the half squat (8.2 and 8.5 / p = 0.8), pronated barbell row (8.4 and 8.4 / p = 0.7) and biceps curl (8.6 and 8.7 / p = 1.0). Higher load values on SP and UP were respectively found in half squat (83.9kg and 70.3kg / p <0.001) and pronated barbell row exercises (53.2kg and 48.6kg / p = 0.01) on SP. However, biceps curl showed dissimilar behavior (48.2kg and 47.4kg / p = 0.5). It was concluded that UP does not promote differences in PSE responses even working with smaller load or similar load.


Resumo Objetivou-se comparar a percepção subjetiva do esforço (PSE) e a carga total levantada nos exercícios resistidos em plataformas estáveis (PE) e plataformas instáveis (PI). Participaram do estudo 20 homens (24,6 ± 3,4 anos, 179 ± 0,1 cm, 80,6 ± 9,1 Kg e 11,8 ± 3,4 % de gordura). Cada voluntário realizou um teste de 15 repetições máximas nos exercícios meio agachamento (solo e discos de equilíbrio), remada curvada pronada (solo e bosu) e rosca bíceps (solo e discos de equilíbrio) em ambas as condições. Foram medidas a PSE através da escala de OMNI-RES e o valor da carga levantada (kg). Para verificar a normalidade dos dados, utilizou-se o teste Shapiro-Wilk. As possíveis diferenças relacionadas às cargas e à PSE nas plataformas foram realizadas pelo teste t pareado. Adotou-se um nível de significância de p<0,05. Não foram encontradas diferenças significativas entre os valores da PSE em PE e PI respectivamente, no meio agachamento (8,2 e 8,5 / p=0,8), remada curvada pronada (8,4 e 8,4 / p=0,7) e rosca bíceps (8,6 e 8,7 / p=1,0). Foram encontrados maiores valores de carga em PE e PI respectivamente, nos exercícios de meio agachamento (83,9kg e 70,3kg / p<0,001) e remada curvada pronada (53,2kg e 48,6kg / p=0,01) na PE. Em contrapartida, para a rosca bíceps não ocorreu o mesmo (48,2kg e 47,4kg / p=0,5). É possível concluir que as PI não promovem diferenças nas respostas da PSE mesmo sendo trabalhadas com uma menor carga ou com uma carga semelhante.

2.
Braz. j. phys. ther. (Impr.) ; 16(3): 216-224, May-June 2012. ilus, graf
Article in English | LILACS | ID: lil-641679

ABSTRACT

BACKGROUND: Given the variety of available hand-held dynamometers and their different handle shapes, reliability studies are needed. Objectives: To compare the accuracy and reliability between three different hand-held dynamometers and analyze the influence of their handles on grip strength. Methods: The tests were performed with the Jamar® dynamometer, the Takei® dynamometer and the EMG System Manual Transducer with modified handle. Eighteen healthy volunteers aged 20.0±1.3 years without history of musculoskeletal disorders or trauma in the evaluated limbs were included. Data normality was tested using the Shapiro-Wilk test. To verify possible differences between the dynamometers, repeated measures ANOVA was administered, followed by Tukey post-hoc tests. Reliability between measurements was evaluated using intraclass correlation coefficient (ICC) and agreement was tested using Bland and Altman plots. The dynamometers calibration process was evaluated using linear regressions. RESULTS: We observed statistically significant differences on the female group between the Jamar® and the Takei® dynamometers (females p<0.001 and males p=0.022) and the EMG System Manual Transducer (female p<0.001 and males p=0.007). However, the Takei® dymamometer and the EMG System Manual Transducer were similar for both female (p=0.161) and male groups (p=0.850). Although acceptable values of intraclass correlation coefficients between measurements were identified, low agreement between the Jamar® dynamometer and all other instruments was found. CONCLUSIONS: The results demonstrated that there is an influence of the dynamometer's handle shapes on the measurements of grip strength. Furthermore, the results demonstrated the need for previous calibration of this type of instrument.


CONTEXTUALIZAÇÃO: Dada a variedade de dinamômetros disponíveis para mensurar a força de preensão manual com diferentes formatos de empunhaduras, estudos de confiabilidade fazem-se necessários. Objetivos: Comparar a exatidão e a precisão das medidas de três dinamômetros distintos e analisar a influência do perfil de empunhadura de cada um. MÉTODOS: Os testes foram realizados com os dinamômetros Jamar®, Takei® e o Transdutor Manual EMG System com empunhadura modificada. Foram avaliados 18 voluntários saudáveis, com idade de 20±1,3 anos, sem histórico de doença musculoesquelética ou traumas nos membros avaliados. A normalidade dos dados foi testada por meio do teste Shapiro-Wilk. Para verificar as possíveis diferenças entre as medições dos dinamômetros, aplicou-se uma ANOVA para medidas repetidas seguida do post-hoc de Tukey. A confiabilidade entre as medidas foi avaliada por meio do Coeficiente de Correlação Intraclasse (CCI), e a concordância foi testada utilizando o procedimento de Bland e Altman. Para o procedimento de calibração dos dinamômetros, procedeu-se à análise de regressão linear e de covariância. RESULTADOS: Observou-se diferença estatisticamente significativa entre o dinamômetro Jamar® e os dinamômetros Takei® (feminino p<0,001 e masculino p=0,022) e Transdutor (feminino p<0,001 e masculino p=0,007). Todavia, Takei® e Transdutor mostraram-se semelhantes para o grupo feminino (p=0,161) e masculino (p=0,850). Apesar de valores aceitáveis de correlação intraclasse entre as medidas, pode-se observar baixa concordância entre o dinamômetro Jamar® e dos demais instrumentos. CONCLUSÕES: Constatou-se a influência dos formatos das empunhaduras na medição da força muscular de preensão da mão como também a necessidade de calibração prévia desse tipo de instrumento.


Subject(s)
Female , Humans , Male , Young Adult , Hand Strength , Muscle Strength Dynamometer , Equipment Design , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL