J. appl. oral sci ; 20(4): 449-454, July-Aug. 2012. ilus, tab
Article in English | LILACS | ID: lil-650622

ABSTRACT

There are several methods for identifying carious dentinal tissue aiming to avoid removal of healthy dentinal tissue. OBJECTIVES: The purpose of this study was to test different methods for the detection of carious dentinal tissue regarding the amount of carious tissue removed and the remaining dentin microhardness after caries removal. MATERIAL AND METHODS: The dentin surfaces of 20 bovine teeth were exposed and half of the surface was protected with nail polish. Cariogenic challenge was performed by immersion in a demineralizing solution for 14 days. After transverse cross-section of the crown, the specimens were divided into four groups (n=10), according to the method used to identify and remove the carious tissue: "Papacárie", Caries-detector dye, DIAGNOdent and Tactile method. After caries removal, the cross-sectional surface was included in acrylic resin and polished. In a microhardness tester, the removed dentin thickness and the Vickers microhardness of the following regions were evaluated: remaining dentin after caries removal and superficial and deep healthy dentin. RESULTS: ANOVA and Tukey's test (α=0.05) were performed, except for DIAGNOdent, which did not detect the presence of caries. Results for removed dentin thickness were: "Papacárie" (424.7±105.0; a), Caries-detector dye (370.5±78.3; ab), Tactile method (322.8±51.5; bc). Results for the remaining dentin microhardness were: "Papacárie" (42.2±10.5; bc), Caries-detector dye (44.6±11.8; abc), Tactile method (24.3±9.0; d). CONCLUSIONS: DIAGNOdent did not detect the presence of carious tissue; Tactile method and "Papacárie" resulted in the least and the most dentinal thickness removal, respectively; Tactile method differed significantly from "Papacárie" and Caries-detector dye in terms of the remaining dentin microhardness, and Tactile method was the one which presented the lowest microhardness values.


Subject(s)
Animals , Cattle , Dental Caries/diagnosis , Dental Caries/therapy , Dentin/chemistry , Analysis of Variance , Dentin/drug effects , Fluorescence , Hardness Tests , Papain , Propylene Glycols , Reproducibility of Results , Rhodamines , Surface Properties
2.
Braz. dent. j ; 21(4): 301-304, 2010. graf, tab
Article in English | LILACS | ID: lil-562089

ABSTRACT

This study evaluated the dimensional alterations and the solubility of two experimental endodontic sealers based on Copaifera multijuga oil-resin (Biosealer) and castor oil bean cement (Poliquil), maintained in different storage solutions. Twenty specimens (3 mm diameter and 2 mm height) of each sealer were assigned to 2 groups (n=10) according to the storage solution: simulated tissue fluid (STF) or distilled water (DW). The specimens were stored in these solutions during 90 days, being removed every 30 days for weighting. The solutions were renewed every 15 days. The results were subjected to statistical analysis by Dunn's and Mann-Whitney tests (a=0.05). The solubility of Poliquil was higher in STF (38.4 ± 36.0) than in DW (28.4 ± 15.0), while Biosealer showed higher solubility in DW (34.61 ± 6.0) than in STF (18.59 ± 8.0). The storage solution influenced the behavior of sealers in relation to the weight variation (p=0.0001). Poliquil presented higher variation of weight independent of the solution (p=0.239). Biosealer also presented higher variation of weight regardless of the solution (p=0.0001). The solubility of Biosealer was different from that of Poliquil, but both sealers showed low solubility in STF. Under the tested conditions, neither of the materials were according to the ADA'S specification.


O presente estudo avaliou a alteração dimensional e solubilidade de 2 cimentos experimentais (à base de resina do óleo de Copaíba - Biosealer e cimento do polímero da mamona - Poliquil), mantidos em diferentes meios de armazenamento. Foram confeccionados 20 espécimes de cada cimento com 3 mm de diâmetro e 2 mm de altura os quais foram divididos em 2 grupos (n=10) de acordo com o meio de armazenamento (fluido tissular simulado ou água destilada). Os espécimes foram atidos nas soluções durante 90 dias, sendo removidos a cada 30 dias para pesagem das amostras, no entanto as soluções foram trocadas a cada 15 dias. Os resultados foram submetidos aos testes de Dunn (5 por cento) e Mann-Whitney. Os meios de armazenamento causaram influência no comportamento dos cimentos em relação ao peso (p=0,0001). Poliquil apresentou alta variação de peso independente da solução (p=0,239). Biosealer também apresentou alta variação de peso independente da solução (p=0,0001). A solubilidade do Biosealer foi diferente do Poliquil, entretanto, ambos cimentos mostraram baixa solubilidade no fluido tissular simulado. Nas condições do experimento, nenhum cimento está de acordo com a especificação da ADA.


Subject(s)
Dental Cements/chemistry , Plant Oils/chemistry , Resins, Plant/chemistry , Root Canal Filling Materials/chemistry , Ricinus communis , Dental Marginal Adaptation , Dental Leakage/prevention & control , Fabaceae , Materials Testing , Solubility , Statistics, Nonparametric , Time Factors
3.
Braz. oral res ; 22(1): 25-30, Jan.-Mar. 2008. graf
Article in English | LILACS | ID: lil-480579

ABSTRACT

The aim of this study was to determine the effect of the exposure of different endodontic materials to different dye solutions by evaluating the optical density of the dye solutions. Seventy-five plastic tubes were filled with one of the following materials: AH Plus, Sealapex, Portland cement, MTA (Angelus and Pro Root) and fifteen control plastic tubes were not. Each specimen of material and control was immersed in a container with 1 ml of each dye solution. A 0.1 ml-dye solution aliquote was removed before immersion and after 12, 24, 48 and 72 hours of each specimen immersion to record its optical density (OD) in a spectrophotometer. Statistical analysis was performed with ANOVA and Tukey tests (5 percent). No significant difference was found among any of the solution OD values for AH Plus cement. Portland cement promoted different OD values after 12 hours of immersion. MTA-Angelus cement presented different OD values only for 2 percent rhodamine B and the MTA-Pro Root cement presented different OD values in all 2 percent rhodamine B samples. Sealapex cement promoted a reduction in the India Ink OD values. Dye evaluation through OD seems to be an interesting method to select the best dye solution to use in a given marginal leakage study.


Subject(s)
Coloring Agents/chemistry , Dental Leakage/diagnosis , Methylene Blue/chemistry , Root Canal Filling Materials/chemistry , Analysis of Variance , Dental Cements , Hydrogen-Ion Concentration , Materials Testing , Spectrophotometry/methods , Time Factors
4.
Ciênc. odontol. bras ; 10(2): 75-84, abr.-jun. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-518118

ABSTRACT

O objetivo deste trabalho foi avaliar a densidade óptica das soluções corantes azul de metileno 2% tamponada e nãotamponada, rodamina B 2% tamponada e não tamponada, antes e após a imersão de dois materiais retrobturadores por diferentes períodos de tempo. As soluções corantes, sem a imersão dos espécimes, foram analisadas nos períodos de 0,12, 24, 48 e 72 horas. Foram preparados oitenta espécimes de cimento Sealer 26 e oitenta de cimento de Portland, os quais foram imersos em 0,7 ml de cada uma das soluções corantes e avaliados nos períodos de tempo de 12, 24, 48 e 72 horas. A densidade óptica foi avaliada em espectrofotômetro ajustado em 596nm para o azul de metileno e 566nmpara a rodamina B. Os dados obtidos foram analisados através dos testes ANOVA (3 fatores) e Tukey 5%. Os resultados mostraram que houve diferença estatisticamente significativa nos valores da densidade óptica do azul de metileno 2% tamponado após a imersão do Sealer 26 nos períodos de 24, 48 e 72 horas em relação ao tempo de 12 horas. Houve diferença estatisticamente significativa nos valores da densidade óptica da rodamina B 2% tamponada após a imersão do cimento de Portland nos períodos de 12, 24 e 48 horas em relação ao tempo de 72 horas. Pôde-se verificar que as soluções corantes não tamponadas apresentaram valores menores de densidade óptica. Dentre as soluções corantes analisadas,a rodamina B 2% tamponada apresentou comportamento mais estável quanto aos valores de densidade ópticaaté o período de avaliação de 48 horas.


Subject(s)
Coloring Agents , Dental Materials , Root Canal Filling Materials , Analysis of Variance , Methylene Blue , Rhodamines
5.
Braz. dent. j ; 16(3): 187-191, set. -dez. 2005.
Article in English | LILACS | ID: lil-419840

ABSTRACT

O objetivo deste estudo foi avaliar o selamento de ápices radiculares tratados com diferentes agentes desmineralizantes e retrobturados com agregado de trióxido mineral (MTA), mediante infiltração marginal por corante. Cinqüenta e seis dentes unirradiculares humanos extraídos foram instrumentados, obturados e seccionados apicalmente. Os preparos cavitários apicais foram confeccionados com pontas ultra-sônicas e os agentes desmineralizantes foram aplicados previamente à retrobturação com Pro Root MTA. Os espécimes foram divididos aleatoriamente em 4 grupos (n=14): grupo 1 (sem agente desmineralizante); grupo 2 (ácido fosfórico 35% durante 15 s); grupo 3 (solução de EDTA 17%, pH 7, durante 3 min); grupo 4 (gel de EDTA 24%, pH 7, durante 4 min). A extensão da infiltração de corante (rodamina B 2% a 37°C, por 24 h) foi avaliada em milímetros utilizando-se um estereomicroscópio. Os resultados foram analisados estatisticamente por meio de análise de variância a um critério e do teste Tukey com nível de significância de 5%. Dentre os grupos experimentais, a menor extensão de infiltração do corante foi verificada no grupo 1 (1,89 mm), seguido pelos grupos 2 (2,18 mm), 4 (2,54 mm) e 3 (2,64 mm). Não houve diferenças estatisticamente significante (p>0.05) na infiltração marginal pelo corante entre os grupos 1, 2 e 4 e os grupos 2, 3 e 4. Com base nos resultados obtidos, pode-se concluir que a aplicação de agentes desmineralizantes não pode ser recomendada quando da utilização do MTA em cirurgias parendodônticas.


Subject(s)
In Vitro Techniques , Tooth Apex , Tooth, Nonvital , Analysis of Variance , Root Canal Filling Materials , Tooth Demineralization
7.
Ciênc. odontol. bras ; 6(1): 51-59, jan.-mar. 2003. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-407294

ABSTRACT

O propósito deste trabalho foi o de avaliar in vitro as alterações do pH e liberação de íons cálcio, após a utilização intracanal, de pastas de hidróxido de cálcio com diferentes veículos. Nesse estudo foram utilizados 46 dentes unirradiculados bovinos, que tiveram suas coroas removidas, após isso realizou-se o preparo biomecânico 1 mm aquém do forame com irrigação de hipoclorito de sódio 2,5 por cento, seguido de irrigação final com EDTA. No terço médio de cada espécime na superfície radicular externa, foi realizado um preparo com 4 mm de comprimento X 2 mm de largura e 1 mm de profundidade. Os canais foram preenchidos com pastas de hidróxido de cálcio e para isso foram divididos em grupos de acordo com o veículo utilizado, G1: detergente; G2: solução salina; G3: polietilenoglicol 400 + paramonoclorofenol furacinado (PMCF). As raízes foram impermeabilizadas externamente, exceto na área da cavidade, imersas individualmente em frascos contendo 4ml de solução salina fisiológica e, mantidas à 37°C. As mensurações de pH e liberação de cálcio foram feitas aos sete e 14 dias. O Calen PMCC foi estatisticamente superior em todas as análises, seguido pelo PMCF e solução salina, que se equivaleram e por último o detergente que foi estatisticamente inferior aos demais grupos. O período de 14 dias mostrou maior aumento na liberação iônica


Subject(s)
Calcium Hydroxide , Root Canal Filling Materials , Tooth Permeability