Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
J. vasc. bras ; 22: e20210181, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1448590

ABSTRACT

Resumo Contexto O uso do endolaser para doença venosa crônica envolve a escolha do comprimento de onda, fibra óptica e energia dispensada. Sua eficácia é avaliada pela taxa de oclusão venosa e, a segurança, pelos efeitos colaterais. Objetivos Demonstrar a incidência de oclusões venosas totais de veias safenas pós-endolaser no seguimento de 1 ano. Descrever a incidência e os efeitos colaterais e a necessidade de reintervenção ou complemento da terapêutica no pós-operatório. Métodos Estudo observacional retrospectivo de uma coorte com abordagem quantitativa de pacientes com insuficiência das veias safenas tratados com laser ablação endovenosa de 1.470 nm. Dados cadastrados em planilha MS Excel 2019, com cálculos de médias e desvios padrão pelo suplemento Power Query do Software. Resultados Foram elegíveis para o estudo 38 pacientes e 104 segmentos venosos, dos quais 100% estavam ocluídos em 30 dias e 99,04% em 1 ano pós-procedimento. O Linear Endovenous Energy Density médio para safena interna foi de 2.040,52 W/cm/s com desvio padrão ± 1.510,06 W/cm/s e 1.168,4 W/cm/s com desvio padrão de ± 665,011 W/cm/s para safena externa. Dor no trajeto da safena foi o principal efeito colateral, com oito casos (21,05%), seguido de parestesia, com um caso (2,63%). Conclusões Taxa de oclusão total no seguimento de 1 ano sugerindo técnica promissora e com atual aplicabilidade na amostra. A incidência da dor e parestesia podem ser justificadas pela alta média de energia utilizada em alguns casos. Recomenda-se a realização de estudos multicêntricos, com amostras maiores e mais homogêneas em relação à classificação Clínica-Etiológica-Anatômica-Patológica.


Abstract Background Use of endolaser for chronic venous disease involves choosing the laser wavelength and optical fiber to use and the quantity of energy to be administered. Efficacy is assessed by the venous occlusion rate and safety is evaluated in terms of side effects. Objectives To determine the incidence of total post-endolaser saphenous vein occlusion at 1-year follow-up. To describe side effects and their incidence and rates of reintervention or supplementary treatment during the postoperative period. Methods A retrospective, observational cohort study with a quantitative approach, enrolling patients with saphenous vein incompetence treated with intravenous 1,470 nm laser ablation. Data were input to an MS Excel 2019 spreadsheet, calculating means and standard deviations with the software's Power Query supplement. Results 38 patients and 104 venous segments were eligible for the study. 100% were occluded at 30 days and 99.04% were still occluded at 1 year after the procedure. Mean Linear Endovenous Energy Density administered to the internal saphenous vein was 2,040.52 W/cm/s with standard deviation of ± 1,510.06 W/cm/s and 1,168.4 W/cm/s with standard deviation of ± 665.011 W/cm/s was administered to the external saphenous vein. Pain along the saphenous path was the most common side effect, with eight cases (21.05%), followed by one case of paresthesia (2.63%). Conclusions The total occlusion rate at 1-year follow-up suggests the technique is promising and is currently applicable in this sample. The incidence of pain and paresthesia may be caused by the high mean energy delivered in some cases. It is recommended that multicenter studies be conducted with larger and more uniform samples in terms of their Clinical-Etiological-Anatomical-Pathological classifications.

SELECTION OF CITATIONS
SEARCH DETAIL