Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Arq. bras. oftalmol ; 75(2): 89-91, mar.-abr. 2012. ilus
Article in English | LILACS | ID: lil-640152

ABSTRACT

PURPOSE: To analyze the antimicrobial properties of silicon oil (Óleo de Silicone®, Ophthalmos, Brazil) on in vitro bacterial growth of different microorganisms related to endophthalmitis. METHODS: The following microorganisms were analyzed: (1) Pseudomonas aeruginosa (ATCC 27583); (2) Escherichia coli (ATCC 25922); (3) Staphylococcus aureus (ATCC 25923); (4) Staphylococcus epidermidis (ATCC 12228); (5) Candida albicans (ATCC 10231); (6) Klebsiella pneumoniae (ATCC 13883); and (7) Streptococcus pneumoniae (ATCC 49619). The plates were incubated at 35 ± 2ºC and its growth examined after 24 hours. An empty disk was placed in the center of each plate as a control. RESULTS: No inhibition halos were verified in any of the plates containing the four different concentrations of the bacterial inocula. CONCLUSIONS: The silicon oil 1000 cps does not have any effect on bacterial growth of any of the studied microrganisms.


OBJETIVO: Analisar as propriedades antimicrobianas do óleo de silicone (Óleo de Silicone®, Ophthalmos, Brazil) no crescimento in vitro de diferentes microrganismos relacionados à endoftalmite. MÉTODOS: Os seguintes microrganismos foram analisados: (1) Pseudomonas aeruginosa (ATCC 27583); (2) Escherichia coli (ATCC 25922); (3) Staphylococcus aureus (ATCC 25923); (4) Staphylococcus epidermidis (ATCC 12228); (5) Candida albicans (ATCC 10231); (6) Klebsiella pneumoniae (ATCC 13883); and (7) Streptococcus pneumoniae (ATCC 49619). As placas foram incubadas à temperatura de 35 ± 2ºC e o seu crescimento examinado após 24 horas. Um disco de papel filtro neutro, sem óleo de silicone, foi posicionado no centro de cada placa como controle. RESULTADOS: Não foram encontrados halos de inibição em nenhuma das placas contendo as diferentes concentrações de inóculo bacteriano estudadas. CONCLUSÕES: O Óleo de Silicone® 1000 cps não apresenta efeito no crescimento bacteriano de nenhum dos microrganismos estudados.


Subject(s)
Humans , Anti-Infective Agents/pharmacology , Candida albicans/drug effects , Endophthalmitis/microbiology , Gram-Negative Bacteria/drug effects , Gram-Positive Bacteria/drug effects , Silicone Oils/pharmacology , Candida albicans/growth & development , Gram-Negative Bacteria/growth & development , Gram-Positive Bacteria/growth & development , Microbial Sensitivity Tests
2.
Arq. bras. oftalmol ; 72(1): 18-22, jan.-fev. 2009. ilus, graf
Article in English | LILACS | ID: lil-510015

ABSTRACT

PURPOSE: To evaluate retinal toxicity of varying doses of rapamycin when injected intravitreally in rabbits. Rapamycin is a potent immunosuppressive agent with significant antitumor and antiangiogenic properties, clinically approved for prevention of organ transplant rejection. METHODS: Twelve New Zealand albino rabbits were divided into four groups. Four different doses of rapamycin were prepared in 0.1 ml: 20 µg, 50 µg, 200 µg, and 1000 µg. Each concentration was injected in one eye of three rabbits, and 0.1 ml volume of sterile BSS was injected into the contralateral eye of the three rabbits. Slit-lamp and fundoscopic examinations were performed and the animals were observed for 2 weeks for signs of infection, inflammation, and toxicity. A baseline ERG was performed before drug treatment and at day 14, after which the rabbits were euthanized. Histology of the enucleated eyes was studied to look for retinal toxicity. RESULTS: ERG results showed some decrease in scotopic response; however this was not dose related. ERG results were normal at 20 µg. Histological results showed no retinal toxicity in all groups. CONCLUSION: Although ERG changes were identified at dosages between 50-1000 µg, the histology of all groups up to 1000 µg did not show any discernable abnormalities.


OBJETIVO: Avaliar a toxicidade da injeção intravítrea de diferentes doses de rapamicina para a retina de coelhos. Rapamicina é uma potente droga imunossupressora aprovada clinicamente para a prevenção da rejeição de transplantes de orgãos. MÉTODOS: Doze coelhos albinos da Nova Zelândia foram usados neste estudo. Foram divididos em quatro grupos. Quatro diferentes doses de rapamicina foram preparadas nas seguintes concentrações: 20 µg, 50 µg, 200 µg, 1000 µg. Foram realizadas injeções intravítreas de 0,1 ml de cada concentração em um olho de três coelhos e 0,1 ml de solução salina foi injetada no olho contralateral de cada coelho. Foram realizadas biomicroscopia e fundoscopia e observamos sinais de inflamação, infecção ou toxicidade durante duas semanas. Fizemos um ERG antes do tratamento e outro 14 dias depois da injeção intravítrea. Os animais foram sacrificados, fizemos a enucleação dos olhos e preparamos o tecido para a avaliação histológica. RESULTADOS: Os resultados do ERG e da histologia demonstraram diminuição da resposta escotópica, entretanto essa diminuiçãão foi dose dependente. A histologia foi normal em todos os grupos. CONCLUSÃO: A injeção intravítrea de rapamicina levou a alterações eletrorretinográficas nos grupos de 50-1000 µg, entretanto a histologia foi normal em todos os grupos até 1000 µg.


Subject(s)
Animals , Rabbits , Immunosuppressive Agents/adverse effects , Sirolimus/adverse effects , Vitreous Body/drug effects , Immunosuppressive Agents/administration & dosage , Models, Animal , Retina/drug effects , Retina/pathology , Sirolimus/administration & dosage
SELECTION OF CITATIONS
SEARCH DETAIL