Rev. cuba. med. trop ; 51(2): 99-105, May-Aug. 1999.
Article in Spanish | LILACS | ID: lil-333528

ABSTRACT

An indirect ELISA test was optimised in which B meningoccocus outer membrane proteins included in the Cuban Vaccine known as VA-MENGOC-BC were used as capture antigents. Specific antibodies in serum samples from vaccinated individuals were detected using a human anti-IgG conjugate, i.e. alklayne phosphatase, thus the reaction developed with a specific substrate called p-nitrophenilphophate. Standard serum was obtained from a reference standard, the gage curve range was 625 to 20,000/mL. The control serum was selected from the most interesting areas for the samples, hence, assay characteristics were determined. Intra-assay, inter-assay and total inaccuracies were lower than 10 in the most linear area of the curve. Detectability was 700/mL. Recovery, paralelism and linearity studies showed an under 10 inaccuracy.


Subject(s)
Humans , Enzyme-Linked Immunosorbent Assay , Immunoglobulin G , Neisseria meningitidis , Bacterial Proteins/immunology , Neisseria meningitidis , Reproducibility of Results , Serotyping