Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Intestinal Research ; : 229-237, 2020.
Article | WPRIM | ID: wpr-834383

ABSTRACT

Background/Aims@#We retrospectively analyzed Crohn’s disease (CD) patients with small intestinal strictures who underwent single-balloon enteroscopy (SBE) to ascertain whether prototype SBEs with a passive bending mechanism and high force transmission insertion tube had better insertability in the small intestine than a conventional SBE. @*Methods@#Among 253 CD patients who underwent SBE, we identified 94 CD patients who had undergone attempted endoscopic balloon dilatation (EBD) for small intestinal stenosis for inclusion in this study. We analyzed whether the type of scope used for their initial procedure affected the cumulative surgery-free rate. For the insertability analysis, patients who underwent SBE at least twice were divided into 3 groups according to the type of scope used: conventional SBE only, prototype SBE only, and both conventional and prototype SBEs. For each group, depth of insertion, procedure time, and number of EBDs were compared in the same patient at different time points. @*Results@#The success rate of EBD was 88.3%. The 5- and 10-year cumulative surgery-free rate was 75.7% and 72.8%, respectively. Cox regression analysis indicated that the factors contributing to surgery were long stricture (≥2 cm), EBD failure, and elevated Crohn’s Disease Activity Index, but not the type of scope used for EBD. The prototype SBEs significantly improved the depth of insertion (P=0.03, Wilcoxon’s signed-rank test). @*Conclusions@#In CD patients with small intestinal stenosis, the prototype SBEs with a passive bending mechanism and high force transmission insertion tube did not improve long-term EBD outcome but did improve deep insertability. (Clinical Trial Registration No. UMIN000037102)

2.
Intestinal Research ; : 265-272, 2019.
Article in English | WPRIM | ID: wpr-764132

ABSTRACT

BACKGROUND/AIMS: There are few prospective studies on cold forceps polypectomy (CFP) using jumbo cup forceps. Therefore, we examined patients with diminutive polyps (5 mm or smaller) treated with CFP using jumbo cup forceps to achieve an adenoma-free colon and also assessed the safety of the procedure and the recurrence rate of missed or residual polyp after CFP by performing follow-up colonoscopy 1 year later. METHODS: We included patients with up to 5 adenomas removed at initial colonoscopy and analyzed data from a total of 361 patients with 573 adenomas. One-year follow-up colonoscopy was performed in 165 patients, at which 251 lesions were confirmed. RESULTS: The one-bite resection rate with CFP was highest for lesions 3 mm or smaller and decreased significantly with increasing lesion size. Post-procedural hemorrhage was observed in 1 of 573 lesions (0.17%). No perforation was noted. The definite recurrence rate was 0.8% (2/251 lesions). The probable recurrence rate, which was defined as recurrence in the same colorectal segment, was 17%. Adenoma-free colon was achieved in 55% of patients at initial resection. Multivariate analysis revealed that achievement of an adenoma-free colon was significantly associated with number of adenomas and years of endoscopic experience. CONCLUSIONS: CFP using jumbo biopsy forceps was safe and showed a high one-bite resection rate for diminutive lesions of 3 mm or smaller. The low definite recurrence rate confirms the reliability of CFP using jumbo biopsy forceps. Number of adenomas and years of endoscopic experience were key factors in achieving an adenoma-free colon.


Subject(s)
Humans , Adenoma , Biopsy , Colon , Colonoscopy , Follow-Up Studies , Hemorrhage , Multivariate Analysis , Polyps , Prospective Studies , Recurrence , Surgical Instruments
SELECTION OF CITATIONS
SEARCH DETAIL