Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Indian J Ophthalmol ; 2019 Apr; 67(4): 557-559
Article | IMSEAR | ID: sea-197202

ABSTRACT

We report the natural course of the accidental injection of trypan blue into the corneal stroma while performing a routine cataract surgery by a resident during a training session. The corneal staining resolved with conservative medical treatment over 7 weeks. This case describes the anterior segment optical coherence tomography (ASOCT) features of corneal staining. It emphasizes on the relatively benign nature of this dye and the follow-up course. Causes that may be responsible for this untoward complication are highlighted with the necessary preventive measures that need to be taken care are also discussed.

2.
Indian J Ophthalmol ; 2019 Apr; 67(4): 555
Article | IMSEAR | ID: sea-197200
3.
Indian J Ophthalmol ; 2019 Jan; 67(1): 38-41
Article | IMSEAR | ID: sea-197047

ABSTRACT

Purpose: To determine the levels of dopamine in tear fluid and demonstrate the use of tear fluid as a non-invasive source for dopamine measurements in humans. Methods: The study cohort included 30 clinically healthy individuals without any pre-existing ocular or systemic conditions. Matched tear fluid (using Schirmer's strips and capillary tubes) and plasma were collected from the subjects. Dopamine levels were evaluated using direct competitive chemiluminescent enzyme-linked immunosorbent assay (ELISA), dopamine kit (Cloud Clone Corp, TX, USA). Results: Significantly higher dopamine levels were found in the tear fluid compared to plasma in the study subjects. The level of dopamine was 97.2 ± 11.80 pg/ml (mean ± SEM), 279 ± 14.8 pg/ml (mean ± SEM), and 470.4 ± 37.64 pg/ml (mean ± SEM) in the plasma and in the tears collected using Schirmer's strips and capillary tubes, respectively. Conclusion: Dopamine was detectable in all the tear fluid samples tested and was also found to be at a higher concentration than in plasma samples. Tear fluid can be used as a non-invasive sample source to monitor dopamine levels.

4.
Indian J Ophthalmol ; 2018 Jul; 66(7): 895
Article | IMSEAR | ID: sea-196788
5.
Indian J Ophthalmol ; 2018 May; 66(5): 661-664
Article | IMSEAR | ID: sea-196700

ABSTRACT

Purpose: The purpose of the study is to compare the efficiency as well as the rate and type of suture-related complications between 10-0 monofilament nylon (Aurolab Nylon Sutures, double arm, Aurolab) and 10-0 polyglactin 910 sutures (Vicryl, single arm, Aurolab) for pediatric cataract surgery. Methods: It is a prospective, comparative study performed in children who underwent surgery for congenital or developmental cataract from March 2013 to February 2016. Patients underwent suturing with either nylon or Vicryl in unilateral cases, but in most bilateral surgeries, one eye received Vicryl sutures while the other eye received nylon. The sutures were compared for their complications and the need for suture removal. Results: Forty-one children (72 eyes) were included in the study, of which 31 children (62 eyes) underwent bilateral surgery while 10 (10 eyes) underwent unilateral surgery. Sixty-four nylon sutures were placed in 32 children (34 eyes), of which 22 (34.4%) were removed due to suture-related complications, whereas 14 (19.7%) (P = 0.03) of the 71 Vicryl sutures placed in 32 children (38 eyes) needed suture removal at an average of 2.9 weeks with the earliest at 6 days postoperatively. The odds of Vicryl suture being removed was 0.42 times with respect to nylon. The most common reason encountered for suture removal in both the materials was sutures becoming loose (16.3%), followed by vascularization (14.1%), infiltration (1.5%), and opacification (4.4%). Conclusion: Absorbable suture such as 10-0 Vicryl is preferred over nonabsorbable suture 10-0 nylon for suturing incisions in pediatric cataract surgery, to avoid subjecting the child to repeated anesthesia.

6.
Indian J Ophthalmol ; 2018 Jan; 66(1): 77-82
Article | IMSEAR | ID: sea-196540

ABSTRACT

Purpose: To evaluate the association between retinal and choroidal thickness and volume along with choroidal vessel volume in children using optical coherence tomography (OCT) images. Methods: 113 normal eyes of children ranging from 5-17 years of age were imaged with a clinical OCT scanner (Optovue Inc., Fremont, USA). The retina, choroid and choroidal vessels were automatically segmented with algorithms. Parameters evaluated were thickness and volume. Location specific analyses of thickness were also performed at a distance of 2.5 mm from foveal center. Multivariate analyses of variance were used to analyze the effect of age and myopia. Manual segmentation of the fovea and subfoveal choroid thickness was also performed to compare with the algorithm segmentation. Results: There was excellent agreement between manual and automatic segmentation (intra-class correlation of 0.95). Within the same eye, total retinal and choroid thickness of nasal and temporal location were significantly lower than the superior and inferior thickness (P < 0.0001). With age (P = 0.026) and myopia (P < 0.001), foveal thickness increased. Choroid volume, vessel volume and temporal choroid thickness increased with increasing myopia (P < 0.05). There was significant positive correlation between choroid volume and retinal volume (r = 0.62, P < 0.0001), choroid volume and vessel volume (r = 0.48, P < 0.0001), and with foveal thickness (r = 0.31, P = 0.009). Choroid vessel volume also showed significant positive correlations with the other metrics (P < 0.05). Conclusion: Retinal and choroidal structural features were quantified simultaneously from OCT images. Magnitude of myopia had a greater effect on retino-choroid features than age in children.

SELECTION OF CITATIONS
SEARCH DETAIL