Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. bras. cardiol. invasiva ; 18(4): 448-455, dez. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-582213

ABSTRACT

INTRODUÇÃO: Apesar do sucesso das intervenções por cateter nos defeitos congênitos em geral, a possibilidade de se dispor de um dispositivo percutaneamente implantável e que desapareça sem deixar vestígios é altamente desejável. Neste estudo apresentamos a experiência inicial dos autores com uma nova prótese parcialmente bioabsorvível. Método: Foram selecionados pacientes portadores de forame oval patente (FOP) com pelo menos um evento embólico prévio, sem defeitos associados, passíveis de correção cirúrgica. O diagnóstico foi feito por meio de ecocardiograma transesofágico (ETE) e teste de bolhas. Durante o procedimento as próteses foram escolhidas de acordo com as medidas de comprimento e abertura do FOP, ao ETE. O seguimento foi realizado por meio de avaliação clínica e ecocardiograma transtorácico com um mês e três meses de ETE aos seis meses após o implante. Os pacientes utilizaram a associação de ácido acetilsalicilico e clopidogrel por três meses a ácido acetilsalicilico isolado nos três meses subsequentes. A profilaxia antimicrobiana...


BACKGROUND: Despite the overall high success rate of per-cutaneous intervention in congenital defects, the possibility of having a percutaneous bioabsorbable implantable device is extremely desirable. The initial experience of the authors with a new partially bioabsorbable prosthesis is reported in this study. METHOD: Patients with patent foramen ovale (PFO), with at least one previous embolic event, without additional surgical defects were selected. Diagnosis was made by transesophageal echocardiography (TEE) and the bubble test. Devices were chosen according to length and opening of PFO at the TEE. Patients were followed-up by transthoracic echocardiogram at 1 and 3 months and TEE at 6 months post implantation. Patients received a combination of acetylsalicylic acid and clopidogrel for 3 months and acetylsalicylic acid for another 3 months. Patients were maintained on antimicrobial prophylaxis for infectious endocarditis for 6 months. RESULTS: Nine patients (5 male and 4 female) were treated from February to August 2010. Mean age was 43.4 ± 13.5 years and mean weight was 71.4 ± 16.3 kg. Pulmonary arterial pressure was normal in all of the patients. PFO tunnel lengths ranged from 6-11 mm and the opening ranged from 2-3 mm. Mean range from rest to stretched PFO opening was 2.1 ± 0.8 mm. Prosthesis implantation was possible in all of the cases. Thirteen devices were used in 9 patients, and one of them required a second device for an additional orifice. No major complications or procedure-related deaths were observed. CONCLUSION: The use of the BioSTAR TM device was safe and effective. It is an excellent alternative for PFO closure.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Prostheses and Implants , Cardiac Catheterization/methods , Cardiac Catheterization , Foramen Ovale, Patent/complications , Foramen Ovale, Patent/diagnosis , Echocardiography/methods , Echocardiography , Prospective Studies
2.
Rev. bras. ortop ; 32(10): 767-70, out. 1997. graf
Article in Portuguese | LILACS | ID: lil-210943

ABSTRACT

Foi realizada reavaliaçäo clínica e radiológica de 92 pacientes somando um total de 111 casos de artroplastia total do quadril com utilizaçäo da prótese cimentada de Charnley, entre 1975 e 1985, no Serviço de Quadril do Hospital de Tráumato-Ortopedia Dr. Mßrio Jorge, com seguimento mínimo de dez anos. Um total de 60 por cento das próteses cimentadas estäo estáveis, sem sinais clínicos ou radiológicos de soltura. Foram encontradas evidências de afrouxamento nos outros 40 por cento, das quais 64 por cento foram do componente acetabular, 23 por cento do femural e 23 por cento em ambos os componentes. Esse percentual está de acordo com a estatística presente nos artigos de toda a literatura mundial, permanecendo a prótese cimentada de Charnley como uma grande alternativa para as artroplastias totais do quadril.


Subject(s)
Humans , Male , Female , Middle Aged , Adult , Cementation/methods , Hip Prosthesis/methods , Evaluation Study , Follow-Up Studies , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL