Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Korean Circulation Journal ; : 958-964, 2000.
Article in Korean | WPRIM | ID: wpr-144613

ABSTRACT

BACKGROUND AND OBJECTIVES: The pathological findings of Non-Q wave myocardial infarction(NQMI) on ECG did not always correspond to subendocardial infarction(SEMI). The purpose of this study was to evaluate the diagnostic validity of ECG for SEMI by myocardial contrast echocardiography (MCE) in the patients with acute myocardial infarction(AMI). MATERIALS AND METHODS: The study population was 84 patients who underwent MCE under the diagnosis of AMI. MCE was performed by intracoronary injection of sonicated Hexabrix into the infarct related artery and SEMI was diagnosed by inspecting endocardial defect with epicardial enhancement on MCE. RESULTS: (1) Among 19 NQMI cases, 7 cases showed SEMI with MCE score 0.5, 11 cases with score 1, and 1 case with score 0. Among 65 Q-wave MI(QMI) cases, only 5 cases showed SEMI. (2) 7 cases who had NQMI with SEMI showed LV wall motion recovery at follow-up echocardiography except 1 case. Whereas, of 5 QMI cases who had SEMI, only 1 case improve LV wall motion. CONCLUSION: NQMI on ECG does not always imply SEMI on MCE, but the absence of pathologic Q wave in the patients with SEMI is thought to be a predictive factor of the recovery of LV wall motion.


Subject(s)
Humans , Arteries , Diagnosis , Echocardiography , Electrocardiography , Follow-Up Studies , Infarction , Ioxaglic Acid
2.
Korean Circulation Journal ; : 958-964, 2000.
Article in Korean | WPRIM | ID: wpr-144601

ABSTRACT

BACKGROUND AND OBJECTIVES: The pathological findings of Non-Q wave myocardial infarction(NQMI) on ECG did not always correspond to subendocardial infarction(SEMI). The purpose of this study was to evaluate the diagnostic validity of ECG for SEMI by myocardial contrast echocardiography (MCE) in the patients with acute myocardial infarction(AMI). MATERIALS AND METHODS: The study population was 84 patients who underwent MCE under the diagnosis of AMI. MCE was performed by intracoronary injection of sonicated Hexabrix into the infarct related artery and SEMI was diagnosed by inspecting endocardial defect with epicardial enhancement on MCE. RESULTS: (1) Among 19 NQMI cases, 7 cases showed SEMI with MCE score 0.5, 11 cases with score 1, and 1 case with score 0. Among 65 Q-wave MI(QMI) cases, only 5 cases showed SEMI. (2) 7 cases who had NQMI with SEMI showed LV wall motion recovery at follow-up echocardiography except 1 case. Whereas, of 5 QMI cases who had SEMI, only 1 case improve LV wall motion. CONCLUSION: NQMI on ECG does not always imply SEMI on MCE, but the absence of pathologic Q wave in the patients with SEMI is thought to be a predictive factor of the recovery of LV wall motion.


Subject(s)
Humans , Arteries , Diagnosis , Echocardiography , Electrocardiography , Follow-Up Studies , Infarction , Ioxaglic Acid
3.
Tuberculosis and Respiratory Diseases ; : 601-608, 1999.
Article in Korean | WPRIM | ID: wpr-157767

ABSTRACT

BACKGROUND: Tuberculous pleural effusion responds well to the anti-tuberculosis agents in general, so no further aggressive therapeutic managements to drain the tuberculous effusion is necessary except in case of diagnostic thoracentesis. But in clinical practice, we often see some patients who later decortication need due to dyspnea caused by pleural thickening despite the completion of anti-tuberculosis therapy in the patients with tuberculous effusion. Especially, the patients with loculated tuberculous effusion might have increased chance of pleural thickening after treatment. The purpose of this study was that intrapleural urokinase instillation could reduce the pleural thickining in the treatment of loculated tuberculous pleural effusion. METHODS: Thirty-seven patients initially diagnosed as having loculated tuberculous pleural effusion were randomly assigned to receive either the combined treatment of urokinase instillation and anti-tuberculosis agents(UK group) and anti-tuberculosis agents(Non-UK group) alone. The 16 patients in UK group received a single radiographically guided pig-tail catheter ranging in size from 10 to 12 French. 100,000 units of urokinase was dissolved in 150 ml of normal saline and instilled into the pleural cavity via pig-tail catheter every day, also this group was treated with anti-tuberculosis agents. While the 21 patients in Non-UK group were teated with anti-tuberculosis agents only except diagnostic thoracentesis. Then we evaluated the residual pleural thickening after treatment for their loculated tuberculous pleural effusion between the two groups. Also the duration of symptoms and the pleural fluid biochemistry like WBC counts, pH, lactic dehydrogenase (LDH), glucose, proteins, and adenosine deaminase (ADA) were compared. RESULTS: 1) The residual pleural thickening (RPT) (5.08 +/- 6.77 mm) of UK group was significantly lower than that (20.32 +/- 26.37 mm) of Non-UK group (Por=10 mm(5.23 +/- 3.89 wks) was significantly longer than the patients with RPT or=10 mm and the patients with RPT <10 mm. CONCLUSION: The treatment of loculated tuberculous pleural effusion with the urokinase instillation via percutaneous transthoraic catheter was effective to reduce the pleural thickening.


Subject(s)
Humans , Adenosine Deaminase , Biochemistry , Catheters , Drainage , Drug Therapy , Dyspnea , Glucose , Hydrogen-Ion Concentration , Oxidoreductases , Pleural Cavity , Pleural Effusion , Prospective Studies , Tuberculosis , Urokinase-Type Plasminogen Activator
SELECTION OF CITATIONS
SEARCH DETAIL