Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Ultrasonography ; : 50-54, 2018.
Article in English | WPRIM | ID: wpr-731003

ABSTRACT

PURPOSE: The aim of this study was to evaluate the correlations between laboratory findings and ultrasonographic measurements of renal length and cortical thickness in patients receiving follow-up for chronic kidney disease (CKD). METHODS: A total of 41 CKD patients (18 males and 23 females; mean age, 65.2 years; range, 42 to 85 years) with a low glomerular filtration rate who did not require renal replacement therapy were included in this prospective study. Patients were followed up with laboratory assays at bimonthly intervals and with ultrasonography performed twice a year. Renal cortical thickness, renal length, and estimated glomerular filtration rate (eGFR) values were compared using the paired-samples t test. Additionally, Pearson correlation analysis was conducted between renal length and cortical thickness measurements and eGFR values to assess kidney function. RESULTS: At the beginning of the study and after 24 months, mean eGFR values of the 41 patients were 35.92 mL/min and 28.38 mL/min, respectively. The mean renal length was 91.29 mm at the beginning of the study and 90.24 mm at the end of the study. The mean cortical thickness was 5.76±2.05 mm at the beginning of the study and 5.28±1.99 mm at the end of the study. A statistically significant positive association was found between eGFR and mean renal length (r=0.66, P < 0.01) and between eGFR and mean cortical thickness (r=0.85, P < 0.01), with the latter being more prominent. CONCLUSION: Our study suggests that ultrasonographic cortical thickness measurements may be an important imaging technique in the follow-up care of patients with CKD.


Subject(s)
Female , Humans , Male , Follow-Up Studies , Glomerular Filtration Rate , Kidney , Prospective Studies , Renal Insufficiency, Chronic , Renal Replacement Therapy , Ultrasonography
2.
The Journal of Advanced Prosthodontics ; : 8-13, 2014.
Article in English | WPRIM | ID: wpr-57068

ABSTRACT

PURPOSE: The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS: A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-microm Al2O3; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (alpha=0.05). RESULTS: There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION: The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.


Subject(s)
Cementation , Ceramics , Dental Porcelain , Hydrofluoric Acid , Resin Cements
3.
The Journal of Advanced Prosthodontics ; : 150-150, 2014.
Article in English | WPRIM | ID: wpr-55974

ABSTRACT

There are some corrections in the body of the article.

4.
The Journal of Advanced Prosthodontics ; : 287-295, 2013.
Article in English | WPRIM | ID: wpr-181916

ABSTRACT

PURPOSE: This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS: Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) (75 mm x 25 mm x 3 mm). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion (50 microm), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (alpha=.05). RESULTS: Denture liner tested showed increased peel strength after laser treatment with different parameters (3.9+/-0.4 - 5.58+/-0.6 MPa) compared to the control (3.64+/-0.5 - 4.58+/-0.5 MPa) and air-abraded groups (3.1+/-0.6 - 4.46+/-0.3 MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups (3.1+/-0.6 MPa). CONCLUSION: Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.