Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Journal of Cerebrovascular and Endovascular Neurosurgery ; : 145-151, 2021.
Article in English | WPRIM | ID: wpr-891363

ABSTRACT

Iatrogenic vessel perforation from endovascular intervention is a devastating complication that commonly is treated with vessel sacrifice. We present a unique case of an iatrogenic proximal basilar artery perforation after submaximal angioplasty in a 67-year-old male presenting with an acute basilar artery occlusion with underlying intracranial atherosclerotic disease. Telescoping flow-diverting stents were then deployed to reconstruct the vessel wall with resulting active hemorrhage resolution. Our case documents a successful deployment of flow-diverting stents with resolution of active hemorrhage after an iatrogenic basilar artery perforation.

2.
Journal of Cerebrovascular and Endovascular Neurosurgery ; : 145-151, 2021.
Article in English | WPRIM | ID: wpr-899067

ABSTRACT

Iatrogenic vessel perforation from endovascular intervention is a devastating complication that commonly is treated with vessel sacrifice. We present a unique case of an iatrogenic proximal basilar artery perforation after submaximal angioplasty in a 67-year-old male presenting with an acute basilar artery occlusion with underlying intracranial atherosclerotic disease. Telescoping flow-diverting stents were then deployed to reconstruct the vessel wall with resulting active hemorrhage resolution. Our case documents a successful deployment of flow-diverting stents with resolution of active hemorrhage after an iatrogenic basilar artery perforation.

3.
Neurointervention ; : 54-57, 2018.
Article in English | WPRIM | ID: wpr-730266

ABSTRACT

A 74-year-old male developed cervical carotid artery psuedoaneurysm 8 months after carotid endarterectomy. The patient was successfully managed with dual implantation of flow-diverter and conventional carotid stent. Flow-diverter was placed across the neck of pseudoaneurysm to provide flow diversion while carotid stent was implanted within the lumen of the expanded flow-diverter to approximate and hold the flow diverter proximal and distal to the pseudoaneurysm. Follow-up ultrasonography revealed complete resolution of the pseudoaneurysm.


Subject(s)
Aged , Humans , Male , Aneurysm, False , Carotid Arteries , Carotid Artery, Common , Endarterectomy , Endarterectomy, Carotid , Follow-Up Studies , Neck , Stents , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL