Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Journal of Public Health and Preventive Medicine ; (6): 45-49, 2023.
Article in Chinese | WPRIM | ID: wpr-965181

ABSTRACT

Objective To establish a method for the determination of 10 organophosphorus flame retardants in drinking water by on-line solid phase extraction coupled with high performance liquid chromatography-tandem mass spectrometry (On-line SPE-UPLC-MS/MS). Methods After adding the internal standard, the water sample was filtered by Millipore filtration, and then concentrated and detected by Online SPE-UPLC-MS/MS. Samples were concentrated by C8 SPE column and separated by C18 column with acetonitrile-water-formic acid as the mobile phases gradient elution,and were detected by multiple reaction monitoring (MRM) acquisition under anion mode. Results The 10 organophosphorus flame retardants all displayed good linear relationships within a certain range of concentrations, with the correlation coefficients being more than 0.990. The method detection limits were 0.60-5.50 ng/L, and the spiked recoveries of low, medium and high concentrations were 64%-106% , 83%-104% and 85%-99%, respectively. Conclusion The method is simple, sensitive, rapid, accurate and reliable, so it is applicable for the determination of 10 organophosphorus flame retardants in drinking water.

2.
Journal of Public Health and Preventive Medicine ; (6): 48-50, 2023.
Article in Chinese | WPRIM | ID: wpr-979159

ABSTRACT

Objective To improve the detection ability of laboratories, and to identify possible technical defects in the detection of dichloroacetic acid and trichloroacetic acid in drinking water. Methods A number of laboratories were organized to conduct interlaboratory determination of dichloroacetic acid and trichloroacetic acid in drinking water. Prefabricated standard series and intermediate samples were distributed. Data of determination were collected and statistically analyzed to evaluate the detection results. Results The slopes of dichloroacetic acid and trichloroacetic acid working curves were analyzed by Grubbs test. The analysis results showed that there were 1 outlier in the dichloroacetic acid data and 3 outliers in the trichloroacetic acid data, respectively. The determination results of the spiked samples of dichloroacetic acid and trichloroacetic acid were 1.5 and 4 times the actual value, respectively. Conclusion This investigation reveals that there exist some technical problems in the direct determination of dichloroacetic acid and trichloroacetic acid by gas chromatography, such as inappropriate selection of chromatographic conditions and injection port flow control, and incorrect way of spiking internal standards.

3.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 467-471, 2023.
Article in Chinese | WPRIM | ID: wpr-986053

ABSTRACT

At present, there are disadvantages with the detection for occupational hazard factors, such as insufficient monitoring data, poor timeliness, weak representativeness, long detection cycles, and inability to continuously monitor. Taking advantages of internet of things technology, an online monitoring platform for occupational hazard factors has been designed. The platform collects the concentration (intensity) of hazard factors through sensors, transmits the occupational hazards data collected online in realtime. The online monitoring cloud center for occupational hazard factors processes and analyzes online monitoring data in realtime, stores the hazard factors data to form database management, and provides user application services to form an intelligent online monitoring service model for occupational hazard factors. Based on the online monitoring platform of occupational hazard factors, multi-level government health supervision departments and employers can grasp the status of hazard factors in real time, which is conducive to improving the level of occupational hazard supervision.


Subject(s)
Internet of Things , Internet
4.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 379-382, 2023.
Article in Chinese | WPRIM | ID: wpr-986018

ABSTRACT

Objective: To explore the sound insulation, sound absorption and other noise reduction transformation methods in a noise workshop handover control room. Methods: In December 2021, through the occupational health investigation and on-site testing of the handover control room of a noise workshop, the causes of excessive noise were analyzed, and the transformation design scheme to reduce noise was proposed and the effect was analyzed. Results: Before the transformation, the peak frequency band noise intensity of the noise workshop handover control room was 112.8 dB (A), and the peak frequency was 1000 Hz. After noise reduction, the theoretical calculated control value was 61.0 dB (A), and the measured noise intensity was 59.8 dB (A) . Conclusion: The noise intensity of the handover control room is reduced after noise reduction, which is in line with the contact limit requirements of the control room in GBZ 1-2010 "Hygienic Standards for the Design of Industrial Enterprises", and has reference significance for noise control engineering.


Subject(s)
Noise/prevention & control , Occupational Health , Industry , Reference Standards , Hygiene , Noise, Occupational/prevention & control
5.
Shanghai Journal of Preventive Medicine ; (12): 596-600, 2022.
Article in Chinese | WPRIM | ID: wpr-936476

ABSTRACT

ObjectiveTo establish a method for the determination of 8 volatile halogenated hydrocarbons in drinking water, including vinyl chloride, trichloroethylene, tetrachloroethylene, tetrachloromethane, chloroform, dichlorobromomethane, dichlorodibromomethane, and tribromomethane by headspace thermal desorption-gas mass spectrometry. MethodsThe water sample was kept in the headspace bottle at 60 ℃ for 40 min, and the volatile matter was transferred to the cold trap,subjected to thermal desorption, then analyzed by gas chromatography-mass spectrometry. ResultsThe linear ranges were 0.2‒20.0 μg·L-1 for vinyl chloride, 0.1‒20.0 μg·L-1 for chloroform, 0.02‒20.00 μg·L-1 for tetrachloromethane, 0.2‒20.0 μg·L-1 for trichloroethylene, 0.3‒20.0 μg·L-1 for dichlorobromomethane, 0.1‒20.0 μg·L-1 for tetrachloroethylene, 0.4‒20.0 μg·L-1 for dichlorodibromomethane, and 1.0‒20.0 μg·L-1 for tribromomethane. All the correlation coefficients were more than 0.997. The respective quantitative limits were 0.162, 0.073, 0.016, 0.184, 0.270, 0.071, 0.356 and 0.813 μg·L-1, and the respective recoveries were 98.0%‒101.0%, 102.0%‒110.0%, 99.2%‒101.0%, 95.5%‒96.2%, 96.0%‒102.0%, 100.0%‒102.0%, 99.0%‒105.0%, and 94.0%‒103.0%. ConclusionThe method is simple, sensitive, rapid, accurate and reliable, so it is applicable for the determination of 8 kinds of volatile halogenated hydrocarbons in drinking water.

6.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 152-155, 2022.
Article in Chinese | WPRIM | ID: wpr-935766

ABSTRACT

Objective: Using CFD technology to grasp the distribution and diffusion of hydrogen fluoride in an electrolytic fluorine plant, provide guidance and scientific basis for enterprises to carry out occupational health management in enterprises, install hazardous substance alarm devices, and protect workers' occupational health. Methods: In July 2019, the diffusion law of hydrogen fluoride gas produced in an electrolytic fluorine plant is selected as the research object. Through the establishment of models and grids, the Fluent numerical simulation method is finally used to simulate the diffusion and distribution of hydrogen fluoride gas under ventilation conditions. Results: The results showed that the average concentration of hydrogen fluoride was 0.045 mg/m(3) in the workplace, and the absorbed zone height (1.5 m) was 0.02 mg/m(3) in the inspection channel, which was in accordance with the national standard. However, there is eddy current above the electrolyzer near the inlet, may lead to the accumulation of hydrogen fluoride gas. Conclusion: The research of CFD numerical simulation method on the distribution and diffusion of hydrogen fluoride concentration in electrolytic fluorine plant can be applied to the prevention, control and management of occupational hazards in electrolytic fluorine plant.


Subject(s)
Humans , Computer Simulation , Fluorides , Hydrofluoric Acid , Occupational Exposure/prevention & control , Occupational Health
7.
Shanghai Journal of Preventive Medicine ; (12): 1070-1075, 2021.
Article in Chinese | WPRIM | ID: wpr-905819

ABSTRACT

Objective:To investigate the association between serum trace elements and dyslipidemia in Pudong New Area. Methods:A community-based cross-sectional study was carried out. A stratified, cluster sampling approach was used for sampling. In total 1 814 community residents aged above 35 years old were recruited in Pudong New Area, Shanghai. A face-to-face investigation was conducted and blood samples were collected. Serum levels of 16 trace elements, including boron, vanadium, chromium, manganese, iron, cobalt, nickel, copper, zinc, arsenic, selenium, strontium, molybdenum, tin, antimony, and barium were measured by inductively coupled plasma mass spectrometry (ICP-MS). The relationship between serum trace elements and dyslipidemia was analyzed with single and multiple Logistic regression models. Results:Prevalence of dyslipidemia is higher among participants of more than 45 years old with high BMI, hypertension or diabetes.Serum iron leveled the highest, followed by copper, zinc, selenium, strontium, boron and other trace elements. After adjusting for potential confounders, the odds ratios of dyslipidemia associated with the highest quartile of trace elements concentrations were 1.41 (95%CI: 1.12-1.78), 0.77 (95%CI: 0.61-0.96), 1.65 (95%CI: 1.31-2.09), 1.27 (95%CI: 1.02-1.58), and 1.32 (95%CI: 1.06-1.66) for chromium, cobalt, zinc, arsenic, and tin, respectively, compared with that associated with the other three quartiles. Conclusion:Some serum trace elements are potentially associated with dyslipidemia in community residents.

8.
China Occupational Medicine ; (6): 203-207, 2021.
Article in Chinese | WPRIM | ID: wpr-923238

ABSTRACT

Kidney is the main target organ of uranium after acute and chronic ingestion. Due to the lack of reliable biomarkers in the study of uranium-induced renal injury, the epidemiological data are not enough to quantify the effects of uranium on human health, and it leads to the inconclusive and inconsistent research results. This paper is focused on the analysis on research progression of domestic and foreign biomarkers of renal injury in uranium drinking water residents, uranium occupational exposure population and Gulf War veterans. The indicators including small molecular proteins and enzymes that reflect the damage of proximal and distal tubules and glomerular, such as β_2-microglobulin, α-microglobulin, retinol binding protein, micro albumin, kidney injury molecule-1, neutrophil gelatinase associated lipocalin, alkaline phosphatase, N-acetyl-β-D-glucosaminase, γ-glutamyltransferase, and lactate dehydrogenase, etc. It is suggested that molecular epidemiology should be applied to long-term cohort studies, and molecular biological detection and analytic techniques should be combined with cohort data information to clarify the dose-effect relationship of biological indicators.

9.
Chinese Journal of Cardiology ; (12): 748-752, 2020.
Article in Chinese | WPRIM | ID: wpr-941170

ABSTRACT

Objective: To compare the predictive value of HAS-BLED, HEMORR2HAGES, ATRIA and ORBIT scores on the bleeding risk in nonvalvular atrial fibrillation (NVAF) patients treated with dabigatran. Methods: Data of 942 NVAF patients participating a non-interventional prospective study of anticoagulant therapy with dabigatran, which was conducted in 12 centers from February 2015 to December 2017 in China, were analyzed. Complete HAS-BLED HEMORR2HAGES, ATRIA and ORBIT bleeding risk scores data and follow-up data were available in the enrolled patients. The endpoint of the study was bleeding events occurred during a 6 months follow-up. Cox proportional hazards models were constructed to analyze the associations between HAS-BLED, HEMORR2HAGES, ATRIA and ORBIT scores and risk of bleeding, and the area under the curve (AUC) of receiver operating characteristics curves (ROC) of each score was used to set the predictive value for bleeding risk. Results: Among the 942 patients, the mean age was (65.3±11.2) years old, 542 (57.5%) were males. A total of 93 (9.9%) bleeding events occurred during follow up, 89 (9.4%) events were minor bleeding, and 4 (0.4%) events were major bleeding. Patients with a high-risk HAS-BLED score had a 1.87-fold increased risk of bleeding compared with low-risk patients (HR = 2.87, 95% CI:1.26-6.51, P = 0.012). There was no statistically significant difference between low-medium-high-risk grading in other scoring systems and bleeding risk (all P>0.05). The AUC (95%CI) of HAS-BLED, HEMORR2HAGES, ATRIA and ORBIT bleeding risk scores were 0.558 (0.525-0.590), 0.520 (0.487-0.553), 0.513(0.480-0.545), 0.523(0.490-0.555), respectively. The AUC of all bleeding score systems were of ≤ 0.700. Conclusion: Among the NVAF patients taking dabigatran in China, the HAS-BLED bleeding risk score is superior to other 3 bleeding risk score on predicting the bleeding risk in these patients, but its predictive value is still relatively low.


Subject(s)
Aged , Humans , Male , Middle Aged , Anticoagulants , Atrial Fibrillation , China , Dabigatran , Prospective Studies , Risk Assessment , Risk Factors , Stroke
10.
Shanghai Journal of Preventive Medicine ; (12): 44-47,53, 2017.
Article in Chinese | WPRIM | ID: wpr-789416

ABSTRACT

Objective To apply the HS-GC method to measure eleven kinds of chlorobenzenes and hexachlorobutadiene in drinking water . Methods We put 10 mL water sample into a 20 mL vial containing 2.5 g sodium chloride .The vial was stirred at 80℃ for 15 mins prior to headspace sampling . Eleven kinds of chlorobenzenes were separated completely by Rtx-1 701 capillary column(30.00 m ×0.25 mm ×0.25 μm),detected by electron capture detectors . Results The linearity of the method ranged from 1.00-32.00 μg/L, 0.20-6.40 μg/L, 0.05-1.60 μg/L, 0.02-0.64 μg/L, 0.02-0.64 μg/L and 0 .01-0 .32 μg/L for dichlorobenzene isomers , trichlorobenzene isomers , tetrachlorobenzene isomers , pentachlorobenzene , hexachlorobenzene and hexachlorobutadiene .In case of a 10 mL water sample , the lowest detected range of mass concentration was 0.001 62-0.262 00 μg/L.The additional standard recovery rate of finished water samples was in the range of 80%-119%with the relative standard deviation (RSD) in the range of 2.24%-4.99%. Conclusion This method is simple, fast, sensitive and needs no organic solvents .It is suitable for measuring both chlorobenzene compounds and hexachlorobutadiene in drinking water simultaneously .

11.
Chinese Journal of Endocrinology and Metabolism ; (12): 11-14, 2016.
Article in Chinese | WPRIM | ID: wpr-484411

ABSTRACT

Objective To explore the correlation of the gene polymorphism of the two single nucleotide polymorphisms(SNPs)rs1443434andrs925489onforkheadboxEl(FOXE1)withthehighnormalthyroidstimulating hormone ( TSH) level in Chinese Han population. Methods 1 400 subjects with normal serum TSH and thyroid peroxidase antibody(TPOAb) levels were included. According to TSH or TPOAb levels, the subjects were divided into high normal TSH group(H-TSH group,n=195) and normal TSH control group(TSH control group,n=1 205) or high normal TPOAb group ( H-TPOAb group, n=711 ) and low normal TPOAb group ( L-TPOAb group, n=689 ) , respectively. The genotypes on the two SNPs of all the subjects were performed by whole-genome genotyping chips. Results There were significant differences in rs925489 genotypic distributions and allele frequencies between H-TSH group and TSH control group(both P<0. 05). The genotype TT and allele T in H-TSH group were significantly higher than those in TSH control group(89. 75% vs 83. 15%, 94. 62% vs 91. 29%). The normal TSH levels were positively associated with rs925489 genotypic distributions after adjustment for sex, age, and high density lipoprotein cholesterol(P<0. 01). There were no significant differences in rs1443434 genotypic distributions and allele frequencies between two TSH groups or two TPOAb groups. Conclusion FOXE1 rs925489 gene polymorphism may be correlated with the high normal TSH level in Chinese Han population.

12.
Chinese Journal of Endocrinology and Metabolism ; (12): 781-783, 2015.
Article in Chinese | WPRIM | ID: wpr-478850

ABSTRACT

[Summary] A total of 1 510 subjects undergoing physical examination in the Central Hospital of Xuzhou were included in this study. According to the level of TSH, the subjects were divided into low TSH group(0. 30-0. 99 mIU/L,n=351), moderate TSH group(1. 00-1. 89 mIU/L, n=703), and high TSH group(1. 90-4. 80 mIU/L, n=456). Analysis of variance and linear regression were used for data analysis. The results showed that systolic blood pressure ( SBP) , diastolic blood pressure ( DBP) , triglyceride ( TG) , and high-density lipoprotein cholesterol( HDL-C) revealed significant differences among 3 group(P<0. 05 or P<0. 01). In the univariate linear regression model, serumTSHwithinthereferencerangewasnegativelyassociatedwithSBPandDBP(P<0.05orP<0.01),and positively associated with TG and HDL-C (P<0. 05 or P<0. 01). However, the correlations disappeared after adjustment for gender, age, body mass index, fasting plasma glucose ( FPG ) , and TG. In the multiple linear regression model, a significant negative correlation of TSH with SBP and FPG was found in males(P<0. 05).

13.
Chinese Journal of Endocrinology and Metabolism ; (12): 602-606, 2012.
Article in Chinese | WPRIM | ID: wpr-427257

ABSTRACT

Thyroid hormones play major roles in the regulation of a wide range of metabolie and physiologic processes.Serum thyroid-stimulating hormone( TSH ) concentration,a sensitive barometer of thyroid function,shows significant individual difference in which genetic variation is a major factor.After using traditional genetic linkage studies and candidate gene association studies to explore the suseeptibility genes of serum TSH,many progresses have been made and new susceptibility genes have been identified by genome-wide association study (GWAS).In this review,we focus on the susceptibility genes of serum TSH levels and also the future prospect that may be obtained from these studies.

14.
Chinese Journal of Endocrinology and Metabolism ; (12): 483-486, 2012.
Article in Chinese | WPRIM | ID: wpr-427205

ABSTRACT

Objective To detect the gene mutation of thyroid hormone receptor β ( TRβ ) in a family with thyroid hormone resistance syndrome.Methods The genomic DNA was extracted from peripheral blood leukocytes of the patient and his 5 family members.The exons 1-10 ofTRβ gene were amplified by PCR.The products of PCR were sequenced directly to detect the gene mutation.Results Two members of this family were confirmed to have the C y A transition mutation at nucleotide 1642 site within exon 10 of TRβ gene,which was a missense mutation causing the substitution of Proline to Threonine (P453T).The mutation was Heterozygous.Conclusions It was confirmed that the patient has TRβ gene mutation P453T in exon 10.The mutation may lead to the occurrence of thyroid hormone resistance syndrome.

15.
Journal of Experimental Hematology ; (6): 1039-1043, 2008.
Article in Chinese | WPRIM | ID: wpr-234304

ABSTRACT

This study was aimed to compare HHGV678 with imatinib (IM) in growth inhibition of Bcr-Abl wild type and IM-resistant cell lines, investigate the possibility of replacing IM with HHGV678 in treatment of chronic myeloid leukemia (CML) and IM-resistant CML patients. Viability of two Bcr-Abl wild type cell lines (K562 and 32Dp210) and 16 IM-resistant cell lines (K562R and 15 Bcr-Abl point mutant cell lines) treated with HHGV678 and IM was analyzed by MTT. The apoptosis of those cells was identified by flow cytometry with Annexin V staining and DNA ladder analysis. Western blot was applied for detecting the expression of Bcr-Abl and phosphotyrosine protein levels. The results indicated that HHGV678 significantly inhibited the growth of two Bcr-Abl wild types and IM-resistant cell lines in dose-dependent manner except cell line of T315I point mutant. IC(50) results showed that the growth inhibition of HHGV678 was 15.5 and 28-fold higher than that of IM in K562, 32Dp210 and 1.4 to 124.3-fold higher than that of IM in 15 IM-resistant cell lines respectively. Compared with IM, HHGV678 more significantly inhibited phosphotyrosine kinase protein of the cells mentioned above at different concentrations. With most importance, HHGV678 of 10.0 micromol/L induced cell apoptosis of 40.06% and 33.32% in K562R and 32Dp210(T315I) cell lines, which were much higher than that of IM (19.77% and 10.68%). It is concluded that HHGV678 is more effective than IM in the growth inhibition of Bcr-Abl wild type cell lines and IM-resistant cell lines, especially in strongest IM-resistant cell lines. Further studies are needed to show whether HHGV678 may be a novel targeting drug in treatment of CML and IM-resistant CML patients.


Subject(s)
Humans , Aminopyridines , Apoptosis , Benzamides , Cell Line, Tumor , Cell Proliferation , Drug Resistance, Neoplasm , Fusion Proteins, bcr-abl , Metabolism , Imatinib Mesylate , Piperazines , Pharmacology , Protein Kinase Inhibitors , Pharmacology , Protein-Tyrosine Kinases , Pyrimidines , Pharmacology
16.
Journal of Environment and Health ; (12)1992.
Article in Chinese | WPRIM | ID: wpr-546286

ABSTRACT

Objective To develop the methods for determination of nitromethane,nitroethane,1-nitropropane,2-nitropropane in the air of workplace. Methods Nitromethane,nitroethane,1-nitropropane,2-nitropropane in the air of workplace were collected by active carbon tube,desorbed in ethyl acetate solution and detected by capillary gas chromatography (GC-FID). Results The linear concentration range of nitromethane,nitroethane,1-nitropropane,2-nitropropane was 43.2-345.3,177.6-1 421.0,68.5-547.7,24.1-192.4 ?g/ml respectively and the relative standard deviation was 1%-5%. Sampling efficiency was 100%,desorption efficiency was 91%-93%. The sample could be resaved at 4-10 ℃ for 5-7 days. Conclusion The method is applicable to determination of nitromethane,nitroethane,1-nitropropane,2-nitropropane in the air of workplace.

SELECTION OF CITATIONS
SEARCH DETAIL