1.
Chinese Medical Equipment Journal ; (6): 1-5, 2017.
Article in Chinese | WPRIM | ID: wpr-511276

ABSTRACT

Objective To develop a novel stress fracture animal model system based on dynamic cyclic mechanical loading.Methods Ulnae and tibiae of rats were respectively fixed using differently shaped fixtures (including a fixed holder and a movable holder).The axial mechanical loading was applied via a linear actuator based on LabVIEW control program.During the loading process,a load cell and a laser displacement transducer were used to detect the force and displacement changes in the limbs,respectively.The two signals were sampled at real time by PC-based LabVIEW data acquisition program.A compressive loading test (peak force of 50 N) was conducted to examine the consistency and reliability of cyclic loads after completing the loading system.The loading system and an ElectroForce 3220 mechanical testing machine were respectively used to measure and compare the Young's modulus of a standard ultra-high molecular weight polyethylene (UHMWPE)cylinder to calibrate the loading system.Results The compressive loading test (peak force of 50 N) demonstrated that the mechanical loading system was able to apply consistent loads with controllable intensity and time.The calibration experiment indicated the accuracy of the loading system.Conclusion The novel mechanical loading device has characteristics of precision,scientificity and reliability,and it is approaching the real development situation of stress fracture,which may provide a reliable experimental base for exploring the precautionary measures of stress fracture.

2.
Chinese Medical Equipment Journal ; (6): 4-8, 2017.
Article in Chinese | WPRIM | ID: wpr-618970

ABSTRACT

Objective To design a test phantom for clinical routine quality control of magnetic resonance imaging (MRI).Methods The commonly used phantom such as Magphan SMR170 and Victoreen 76-903 were used for experiments with the same parameters,and the test data of all the modules were compared.The advantages and disadvantages of all the modules were analyzed,and an optimization scheme was proposed accordingly.Results The phantom could be applied to the detection of high-image-quality MRI machine,and solved the problems in positioning,size matching and etc.Conclusion The new phantom meets the demand of magnetic resonance imaging clinical routine testing,and provides a certain reference for phantom optimization design.

SELECTION OF CITATIONS
SEARCH DETAIL