Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Language
Year range
1.
Chongqing Medicine ; (36): 1194-1195,1198, 2014.
Article in Chinese | WPRIM | ID: wpr-598952

ABSTRACT

Objective To explore the ultrasonographic characteristics and methodology characteristics of fetal limb deformities . Methods A retrospective analysis was made on 6 336 pregnant women accepting systematic prenatal ultrasonography during the period of May 2010 to May 2012 in the General Hospital of Chengdu Military Region .The long bones of the upper and lower limbs were scanned by using the systematic continuous sequence approach (SCSA) and by adding the arc rotaryprocess for observing the hands and feet ,fetal limbs morphology ,structure ,posture and movement ,etc .were dynamically observed .The suspected position or fetal limb deformities were examined with three-dimensional(3D) ultrasonography as the supplementary .The prenatal ultrasound examination results of fetal limb deformities were analyzed .Results Among 6 336 pregnant women ,20 cases of fetal limb deformi-ties were confirmed by induced labor or after birth ,18 cases were diagnosed by the prenatal ultrsound ,including 5 cases of short limbs deformity ,3 cases of fatal dwarf ,1 case of phocomelia ,1 case of double radiuses absence ,1 case of unilateral hand missing ,1 case of double shank absence ,2 cases of polydactyly ,3 cases of foot varus and 1 case of overlapping finger .2 cases of missed diagno-sis were multiple fingers and overlapping finger .Conclusion The abnormality of terminal fingers(toes) number and posture is easy to be missed diagnosis ,which are the difficulty and the key point of examination .

2.
Chinese Journal of Medical Imaging Technology ; (12): 718-720, 2010.
Article in Chinese | WPRIM | ID: wpr-471932

ABSTRACT

Objective To assess the diagnostic value of contrast enhanced ultrasound (CEUS) in liver metastases. Methods Thirty-six patients were examined with conventional ultrasonography, then underwent continuous real-time CEUS with low mechanical index. The size, location, number and perfusion patterns of liver metastases were evaluated. Results In 36 patients, 67 liver metastases were found with conventional ultrasound and 106 liver metastasis were found with CEUS. The perfusion patterns of lesions were in four types: ①Thirty-seven lesions (34.91%) showed as total enhancement during the early arterial phase and hypoechoic appearance during the portal venous phase and the late phase;②Fifty-six lesions (52.83%) showed a peripheral rim-like hyperechonic enhancement during the arterial phase and fast wash-out in the portal phase;③Twelve lesions (11.32%) showed as isoechoic enhancement during the arterial phase and the portal phase and was hypoechoic in the late phase;④One lesion (0.94%) showed hypoechoic appearance during all phases. The dimension of the lesions played an important role in the perfusion patterns. Conclusion The enhancement pattern and time of lesions are closely correlated with the tumor arterial supply. CEUS has high value in diagnosing liver metastases.

3.
Chinese Journal of Tissue Engineering Research ; (53): 152-153, 2005.
Article in Chinese | WPRIM | ID: wpr-408942

ABSTRACT

BACKGROUND: Comparing with diabetic nephropathy and diabetic retinopathy, diabetic cardiomyopathy is put forward exceeded later and the research about it was not enough. It is difficult to detect diabetic cardiomyopathy in the earlier period so that it has usually been neglected.OBJECTIVE: To evaluate features of dysfunction of left ventricle in early diabetic cardiomyopathy by Doppler tissue imaging.DESIGN: Completely randomized and controlled experiment.SETTING: Ultrasound Department of General Hospital of Chengdu Military Area Command of Chinese PLA.MATERIALS: The experiment was carried out at Ultrasound Department of General Hospital of Chengdu Military Area Command of Chinese PLA from March to June 2002. Totally 56 New Zealand rabbits of either gender were selected.METHODS: ① Ten New Zealand rabbits was pulled out randomly from 56 as control group. The rest of 46 New Zealand rabbits were replicated diabetes mellitus by Streptozotocin (STZ), rabbits were absolute diet 18 hours and injected intravenously to ear marginal vein with 65 mg/kg of STZ. Then these rabbits were randomly divided into 4 groups as 2, 4, 6, 8th experimental group, with 10 rabbits in each group. ② Digit ultrasonic cardiogram equipment was used to examined interventricular motion of mitral annulus at 2nd,4th, 6th and 8th week in model groups and comparison group. The parameters such as systolic peak velocity (Sa), preejection period (PEP), local ejection time (ET), systolic mean velocity (Vm) of four various portions in mitral annulus and diastole early period velocity (Ea), diastole later period velocity (Aa), Ea/Aa were determined. ③ SPSS 11.0 was used for statistical analysis,one-factor analysis was adopted to compare difference of groups.MAIN OUTCOME MEASURES: The motion of lateral wall and posterior interventricular septum at mitral annulus were estimated by PW-DTI.RESULTS: Among 56 rabbits, 50 entered the final analysis and other 6 were lost because of failure modeling. Diastole dysfunction of left ventricle was discovered in STZ-inducod diabetic rabbits detected by tissue Doppler imaging at the 4th week. It showed that not only the tite of early period of diastole peak velocity (Ea) in mitral ring lateral wall and post-interval of left ventricle was reduced, but also the tite of Ea/Aa was reduced notably (P < 0.05). Systolic dysfunction of left ventricle was discovered in STZ-in-duced diabetic rabbits detected by tissue Doppler imaging at the 6th week.It showed that local contraction peak velocity (Sa) of lateral wall and postseptum of mitral ring was decreased strikingly (P < 0.05). Mean systole velocity of four various parts of mitral ring (Vm) was reduced at the 6th week (P < 0.05). Pre-ejection period time (PEP) at post-septum and ejection time (ET) was elongated at lateral wall at the 8th week (P < 0.05).CONCLUSION: ① Diastolic dysfunction of left ventricle is characterized by decrease of early period of diastole peak velocity and the tite of Ea/Aa.② Systolic dysfunction of diabetic cardiomyopathy is characterized by decrease of local contraction peak velocity and elongation of pre-ejection period time and ejection time.

4.
Chinese Journal of Ultrasonography ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-675671

ABSTRACT

Objective To study the relationship between pre transjugular intrahepatic portosystemic shunt(TIPS) liver hemodynamics and the incidence of post TIPS hepatic encephalopathy(HE).Methods Hepatic blood dynamics was evaluated in 41 cases of liver cirrhosis before TIPS and one month later.The patients were divided into two groups according to Doppler findings before TIPS.Group 1 composed of patients with prograde portal flow,group 2 composed of patients with hepatofugal or back forth portal flow.The clinical characteristics,incidence of post TIPS HE and pre/post TIPS hepatic arterial resistant index(RI) of the groups were compared.The independent prognostic value of pre TIPS variables for the onset of HE after TIPS was tested with a multiple regression analysis.The variables included age,pugh score,presence of HE before TIPS,the pattern of portal flow.Results The two groups did not differ significantly in their age,etiology of liver disease,indications of TIPS placement, HE incidence before TIPS and portacaval gradient before and after TIPS.But liver failure was more severe in group 2(P

5.
Chinese Journal of Ultrasonography ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-675665

ABSTRACT

Objective To explore the value of two dimensional and color Doppler flow imaging(2D CDFI)for the diagnosis and differentiation of the carotid body tumor.Methods Retrospective analysis was made on 12 patients with carotid body tumor examined by 2D CDFI,and differentiations were conducted between several similar diseases.All the cases were confirmed by surgical pathology.Results The carotid body tumor in 2D CDFI was shown as follows: Low echoic substantial masses were found in the carotid branch with clearly boundary,and or partly outline.Most in small size were located at the branch of common carotid artery,so the interval between external and internal carotid arteries was enlarged.The masses in big size always grew around common cartid artery internal carotid artery and external carotid artery.More color flow signals were detected in the masses,and most were artery flow.The relationship between the mass and the carotid was shown clearly by 2D CDFI.Conclusions 2D CDFI is a valuable and practical method in diagnosis of carotid body tumors.

SELECTION OF CITATIONS
SEARCH DETAIL