1.
Chinese Journal of Blood Transfusion ; (12): 655-658, 2022.
Article in Chinese | WPRIM | ID: wpr-1004229

ABSTRACT

【Objective】 To establish gas chromatography for the determination of tributyl phosphate(TBP) residues in human prothrombin complex and then verify it. 【Methods】 Acid modified polyethylene glycol(PEG)(20M) capillary column was used with n-hexane as solvent. The chromatographic parameters were as follows: gasification chamber temperature at 220 ℃, column temperature at 155 ℃, detector temperature at 220 ℃, column flow rate at 2.0 mL/min, carrier gas as N2, detector as FID, and collection time for 10min. The accuracy, repeatability, linearity, specificity, intermediate precision, detection limit, quantitative limit, range and durability were verified. 【Results】 The verification results showed that the method had good specificity. The linear regression correlation coefficient of standard curve was 0.999 90. The recovery rate were 98.4%, 97.5% and 95.7% when the concentration at 50%, 100%(30μg/mL) and 150%, respectively, with an average recovery of 97.2% and a relative deviation of 2.15%. When the concentration was 100%, the repeatability was 2.08%, and the relative deviation of intermediate precision was 1.63%. The detection limit was 0.255 μg/mL, and the quantitative limit was 0.511 μg/mL. After changing capillary chromatographic columns with different batch numbers but the same types and manufacturer, the applicability test of the system met the requirements, and the method had good durability. 【Conclusion】 This method can be used for the determination of TBP residues of human prothrombin complex in laboratory.

2.
Chinese Journal of Blood Transfusion ; (12): 89-92, 2022.
Article in Chinese | WPRIM | ID: wpr-1004053

ABSTRACT

【Objective】 To establish and verify the vacuum decay method for the tightness inspection of blood products. 【Methods】 The method for inspecting the tightness of blood product was established, and the detection limit, linearity, range, accuracy, precision and durability were verified according to the requirements of methodological verification.The validated method was used to check the tightness of blood product packaging. 【Results】 The detection limit of this method was 2.5 μm, linear correlation coefficient was r=1, the differential pressure of positive sample was within the allowable range of accuracy, and the durability met the requirements.The RSD of results of 6 repeatability tests and 12 intermediate precision tests were both less than 10%, and all validation items met the verification standards. 【Conclusion】 Vacuum decay method can be used to check the tightness of blood products.

3.
Journal of Chinese Physician ; (12): 910-913, 2009.
Article in Chinese | WPRIM | ID: wpr-393707

ABSTRACT

Objective To observe the characteristic of precancerous lesions and early gastric carcinoma with narrow belt imaging technology. Methods The 74 patients were enrolled in this study. The same case was used as self-control. The operation was made in pain-less under anesthesia. When the mirror was advanced to the duodenal descending segment, an ordinary microscope mode was used and the mirror was back to Mallory, the lesions found were recorded, the image was zoomed in with low-fold and observed (1.4,1.6,1.8 times). Suspicious lesions were collected and biopsies were made. Results Chronic gastritis could be commonly found in type A and AB. Mild in-testinalization and mild atypical hyperplasia could be commonly found in mixed type holding type C, type BC and AB. Moderate atypical hy-perplasia could be found in type CD and AC, and heavy atypical hyperplasia in type CD and D. Early gastric cancers (superficial depressed) were seen in type BC and irregular thick type A. Advanced gastric cancers were in type CD, D and C. Helicobacter pylori infection were common in type A and B. Protruded type, sunken type were not easily missed with common endoscopic and NBI. But "for ordinary focus of infection, it was easily missed with common endoscopic, while less with NBI. Conclusion NBI is a simple and safe method, which can be used to find precancerous lesions and early gastric cancer lesions more easily. It will enlaance the diagnosis rate of precancerous lesions and early gastric cancer as positive rate of biopsy was markedly improved.