Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Ann Card Anaesth ; 2022 Jun; 25(2): 148-152
Article | IMSEAR | ID: sea-219196

ABSTRACT

Background and Aim:Various devices such as single lumen tubes, balloon?tipped bronchial blockers, and double?lumen tubes can be used for lung isolation in children, but no particular device is ideal. As such, there is a wide variation in lung isolation techniques employed by anaesthesiologists in this cohort of patients. This study aims to describe our experience with Fogarty catheters for lung isolation in children. Methods: This was a single centre, retrospective review of 15 children, below the age of 8 years, undergoing thoracic surgeries and requiring lung isolation. Demographic details, clinical parameters, complications during Fogarty catheter placement, number of attempts for placement, time taken for satisfactory lung isolation, and intraoperative complications were collected. Results: Successful lung isolation was achieved in all 15 children with Fogarty catheters of various sizes with the help of flexible bronchoscopy. Desaturation and bradycardia were the commonest complications seen during placement of the catheters but resolved with bag?mask ventilation. On average, 2 attempts were required for successful Fogarty placement. The mean time for successful lung isolation was 6.9 ± 1.3 minutes. The commonest intraoperative complication noted was desaturation, which resolved with an increase in FiO2 and positive end expiratory pressure. 2 children had migration of the device proximally to the trachea causing airway obstruction. The devices were successfully repositioned in both cases. Conclusion: Fogarty catheters can be used for successful lung isolation in children less than 8 years of age, undergoing thoracic surgery

2.
Ann Card Anaesth ; 2016 Oct; 19(5_suppl): s73-s78
Article in English | IMSEAR | ID: sea-181000

ABSTRACT

During current medical care, perioperative transesophageal echocardiography (TEE) has become a vital component of patient management, especially in cardiac operating rooms and in critical care medicine. Information derived from echocardiography has an important bearing on the patient’s outcome. The Indian Association of Cardiovascular and Thoracic Anaesthesiologists (IACTA) has promoted the use of TEE during routine clinical care of patients undergoing cardiac surgery. An important mission of IACTA is to oversee training and certify anesthesiologists in the perioperative and intensive care use of TEE. The provision of “Fellowship” is by way of conducting IACTA – TEE fellowship (F‑TEE) examination. This has been done annually for the past 7 years using well‑established curriculums by accredited national and international societies. Now, with the transformation and reconstitution of IACTA education and research cell into the newly formed Indian College of Cardiac Anaesthesia, F‑TEE is bound to meet international standards. To ensure that the examinations are conducted in a transparent and foolproof manner, the guideline committee (formulated in 2010) of IACTA has taken the onus of formulating the guidelines for the same. These guidelines have been formally reviewed and updated since 2010 and are detailed here to serve as a guide to both the examinee and examiner ensuring standardization, efficiency, and competency of the IACTA F‑TEE certification process.

3.
Ann Card Anaesth ; 2011 Sept; 14(3): 206-210
Article in English | IMSEAR | ID: sea-139611

ABSTRACT

Interruption of the aortic arch is a rare anomaly affecting 1% of children with congenital heart disease. The systemic circulation is ductal dependent and is determined principally by the ratio of the resistances in the systemic and the pulmonary vascular bed. Any increase in the pulmonary vascular resistance may increase the dead space ventilation due to acute pulmonary hypoperfusion. We report a case where sudden decreases in the end-tidal carbon-dioxide due to pulmonary hypoperfusion mimicked accidental endotracheal tube extubation in an infant undergoing repair of interrupted aortic arch.


Subject(s)
Aorta, Thoracic/abnormalities , Aorta, Thoracic/surgery , Carbon Dioxide/blood , Cardiopulmonary Bypass , Heart Defects, Congenital/surgery , Humans , Hypertension, Pulmonary/etiology , Infant, Newborn , Male , Pulmonary Circulation
SELECTION OF CITATIONS
SEARCH DETAIL