Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Malaysian Orthopaedic Journal ; : 90-2018.
Article in English | WPRIM | ID: wpr-781068
2.
The International Medical Journal Malaysia ; (2): 31-34, 2016.
Article in English | WPRIM | ID: wpr-627180

ABSTRACT

Introduction: Application of dynamic hip screw (DHS) implant for the treatment of unstable intertrochanteric fractures continues to raise concern related to risk of lag screw cut-out with or without subsequent damage to the acetabulum. Measurement of tip-apex distances (TAD) has been recommended to guide the optimal placement of lag screw and to predict subsequent risk of screw cut-out. In this study, the value of TAD was evaluated to verify its usefulness. Methods: This is a retrospective study of 33 consecutive patients with intertrochanteric fracture treated with DHS. Demographic data of the patients were traced from their case notes. Post-operative radiographs were reviewed by focusing on measurement of TAD on anteroposterior and lateral radiographs. Radiographs at one year follow-up were reviewed to depict any fixation-related failure or complication. Results: Fifty two percent of patients did not achieved the recommended TAD of ≤ 25mm. The mean post-operative TAD was 25.9mm and elderly patients were likely to achieve TAD of ≤ 25mm. The overall complication rate of 6% was attributed to screw cut-out in two cases. The unstable left-sided fracture was identified to be a potential risk for screw cut-out or migration. Conclusion: TAD is a valuable measurement to guide optimal placement of lag screw during DHS fixation of intertrochanteric fracture.

3.
The International Medical Journal Malaysia ; (2): 3-6, 2014.
Article in English | WPRIM | ID: wpr-627287

ABSTRACT

This is a cross-sectional study of 37 patients with AO type C (complete intra-articular) fractures of the distal radius, evaluating the functional, anatomical, and patient rated outcomes one year after primary fixation with a volar locking plate. Methods: Functional outcomes were assessed based on the grip strength, and the range of motion of forearm and wrist. Anatomical outcomes were assessed based on the radial inclination, radial height, volar tilt, and articular step or gap. Patient rated outcome was measured with a Disability of arm, shoulder and hand (DASH) questionnaire. Results: One year after surgery, 24 (64%) patients achieved good and excellent anatomical results, and DASH scores were acceptable in 73% of patients. Most of the patients had achieved 80% of their grip strength. The mean DASH score of 12.3 was comparable with other studies. Grip strength, radial inclination and volar tilt had a significant correlation with the DASH score. Conclusion: Volar locking plates can be used to achieve optimal reduction in all three parameters in the treatment of AO type C fractures of the distal radius. Versatile fracture fragment reduction and angular stability enable rehabilitation hence obtaining good functional outcomes.

SELECTION OF CITATIONS
SEARCH DETAIL