1.
Middle East Journal of Anesthesiology. 2010; 20 (5): 719-721
in English
| IMEMR
| ID: emr-105630
ABSTRACT
This is a case of failed intubation in a child of 15 months due to presence of laryngeal web. The airway was maintained by Cole Neonatal tube size 2 mm held at the available orifice of the glottis with maintenance of spontaneous respiration under general anesthesia till emergency tracheostomy was performed