Journal of Lasers in Medical Sciences. 2014; 5 (1): 13-18
in English | IMEMR | ID: emr-146898

ABSTRACT

In this study, we intend to use diffuse optical Tomography [DOT] as a noninvasive, safe and low cost technique that can be considered as a functional imaging method and mention the importance of image reconstruction in accuracy and procession of image. One of the most important and fastest methods in image reconstruction is the boundary element method [BEM]. This method is introduced and employed in our works. Generally, to image a biological tissue we must obtain its optical properties. In order to reach this goal we benefit from diffusion equation because tissue is highly scattering medium. Diffusion equation is solved by boundary element equation [BEM] in our research. First, we assume a double layer phantom with different scattering and absorption coefficients to simulate and verify precession and accuracy of image reconstruction by BEM. Light absorption can be affected by volume fraction of blood in skin. For a specific skin species the volume fraction is calculated and then the results are compared with the reconstructed values obtained by BEM. Since the depth of tissue is important in light absorption a two layer phantom with known values is made and the depths of layers are reconstructed by BEM then they are compared with the expected values. A homogenous phantom with known scattering and absorption coefficients was made and then these coefficients were reconstructed by BEM. Finally, an inhomogeneous phantom [phantom with defect] whose defect was in a known position was made and the absorption and scattering coefficients were reconstructed and compared with real values. Comparison between real or simulated values and reconstructed values of scattering and absorption coefficients, volume fraction of blood and thickness of phantom layers by BEM shows maximum errors of 24%, 7% and 35%, respectively. Comparison between BEM data and real or simulated values shows an acceptable agreement. Consequently, we can rely on BEM as a beneficial method in diffuse optical tomography image reconstruction

2.
Journal of Lasers in Medical Sciences. 2013; 4 (3): 99-106
in English | IMEMR | ID: emr-127081

ABSTRACT

Laser-tissue interaction is of great interest due to its significant application in biomedical optics in both diagnostic and treatment purposes. Major aspects of the laser-tissue interaction which has to be considered in biomedical studies are the thermal properties of the tissue and the thermal changes caused by the interaction of light and tissue. In this review paper the effects of light on the tissue at different temperatures are discussed. Then, due to the noticeable importance of studying the heat transfer quantitatively, the equations governing this phenomenon are presented. Finally a method of medical diagnosis called thermography and some of its applications are explained


Subject(s)
Humans , Animals, Laboratory , Tissues , Hot Temperature , Thermography
3.
Journal of Lasers in Medical Sciences. 2012; 3 (3): 102-108
in English | IMEMR | ID: emr-149330

ABSTRACT

In this study, arrangement of a low-cost optical tomography device compared to other methods such as frequency domain diffuse tomography or time domain diffuse tomography is reported. This low-cost diffuse optical imaging technique is based on the detection of light after propagation in tissue. These detected signals are applied to predict the location of in-homogeneities inside phantoms. The device is assessed for phantoms representing homogenous healthy breast tissues as well as those representing healthy breast tissues with a lesion inside. A diode laser at 780nm and 50 mW is used as the light source. The scattered light is then collected from the outer surface of the phantom by a detector. Both laser and detector are fiber coupled. The detector fiber may turn around the phantom to collect light scattered at different angles. Phantoms made of intralipid as the scattering medium and ink as the absorbing medium are used as samples. Light is collected after propagation in the phantoms and the capability of the device in collecting data and detecting lesions inside the phantoms is assessed. The fact that the detection fiber orbits around the sample and detects light from various angles has eliminated the need to use several detectors and optical fibers. The results obtained from experiments are compared with the results obtained from a finite element method [FEM] solution of diffusion equation in cylindrical geometry written in FORTRAN. The graphs obtained experimentally and numerically are in good accordance with each other. The device has been able to detect lesions up to 13 mm inside the biological phantom. The data achieved by the optical tomography device is compared with the data achieved via a FEM code written in FORTRAN. The results indicate that the presented device is capable of providing the correct pattern of diffusely backscattered and transmitted light. The data achieved from the device is in excellent correlation with the numerical solution of the diffusion equation. Therefore, results indicate the applicability of the reported device. This device may be used as a base for an optical imaging. It is also capable of detecting lesions inside the phantoms.