Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J. health med. sci. (Print) ; 6(4): 291-296, oct.-dic. 2020. ilus
Article in English | LILACS | ID: biblio-1391329

ABSTRACT

The aim of this study was to develop a software for radiological breast mammography anatomy study. A descriptive and exploratory study was carried out using mammography images database. The software was created using well-known open source image J software. Eight mammographic images were selected including standard views: craniocaudal (CC) and mediolateral oblique (MLO) views, and supplementary views. The software was created as an image J plugin-in. The virtual environment presented multiple choice questions related to radiological breast anatomy and patient positioning criteria. The software launches by requiring the user to register their profile ( user ID) followed by the selection of mammography projection technique. As the second step, a screen with multiple choice questions opens according to the technique selected by the user. At the end of the evaluation, a report is presented containing date and time of evaluation, username and the score achieved. The report also provide feedback to the user and highlight where the user incorrectly identified the anatomy. The software allowed assist on multifactor mammography learning process for radiographers. However, It is necessary the improvement of software including high quality images and case study.


El objetivo de este estudio fue de el desarrollo de un software para estudio de anatomía y procedimientos en mamografía de mama. Se realizó un estudio descriptivo y exploratorio utilizando una base de datos de imágenes mamográficas. La aplicación se creó utilizando un conocido software (imagen J) de código abierto. Se seleccionaron ocho imágenes mamográficas que incluían proyecciones estándar: proyecciones craneocaudal (CC) y mediolateral oblicua (MLO) y proyecciones complementarias. El software fue creado como un complemento de imagen J. El entorno virtual presentó preguntas de múltiple opción relacionadas con la anatomía radiológica de la mama y los criterios de posicionamiento del paciente. El software se inicia solicitando al usuario que registre su perfil (ID de usuario) seguido de la selección de la técnica de proyección de mamografía. Como segundo paso, se abre una pantalla con preguntas de opción múltiple según la técnica seleccionada por el usuario. Al final de la evaluación, se presenta un informe que contiene la fecha y hora de la evaluación, el nombre de usuario y la puntuación obtenida. El informe también proporciona comentarios al usuario y destaca dónde el usuario identificó incorrectamente la anatomía. El software permitió asistir en el proceso de aprendizaje de mamografías multifactoriales para radiólogos. Sin embargo lo és necesaria la mejora del software, incluidas imágenes de alta calidad y estudios de casos.


Subject(s)
Humans , Female , Radiology/education , Image Processing, Computer-Assisted , Breast/diagnostic imaging , Mammography , Software , Breast/anatomy & histology , Anatomic Landmarks , Anatomy/education
2.
Rev. Ciênc. Méd. Biol. (Impr.) ; 18(2): 239-248, nov 07, 2019. fig, ilus
Article in Portuguese | LILACS | ID: biblio-1291689

ABSTRACT

Introdução: associadas à composição química, as propriedades físicas dos biomateriais como formato, dimensões e porosidade, são fatores que influenciam na biocompatibilidade, biodegradabilidade e nos potenciais osteoindutivo e osteocondutores. Objetivo: identificar modificações físicas no formato, dimensões e porosidade de um biomaterial com nova composição de wollastonita e beta fosfato tricálcico, implantado em defeitos ósseos críticos em calvária de ratos. Metodologia: trata-se de um estudo exploratório, com um biomaterial compósito, antes e após a sua implantação in vivo. Utilizou-se explantes cirúrgicos de calvárias de ratos que receberam implantes em defeito ósseo crítico. Os animais foram distribuídos em 3 grupos experimentais aleatoriamente, compostos por 5 animais cada, e avaliados com 15, 45 e 120 dias. Os grupos foram denominados: G0-biomaterial; GI-15 dias; GII-45 dias; e, GIII-120 dias. As amostras foram micrografadas em microscópio eletrônico de varredura, com diferentes magnificações. Utilizouse o software livre ImageJ para processamento das imagens e análise das partículas e poros. Resultados: a distribuição espacial do biomaterial promoveu preenchimento completo do defeito ósseo crítico. Micrografias com diferentes magnificações permitiu identificar modificações na área de contato entre grânulos, diminuição dos poros intergranular, aumento da área ocupada pelos poros e diminuição das partículas nos grânulos. Nos grupos GII e GIII, identificou-se formação de componentes orgânicos na superfície do implante. Conclusão: houve modificações físicas no formato, dimensões horizontais, distribuição espacial e porosidade da superfície dos grânulos do biomaterial, relacionadas com a biodegradabilidade e o potencial osteoindutivo e osteocondutor do biomaterial.


Introduction: associated with the chemical composition, physical properties of biomaterials related to their format, dimensions and porosity, are factors that influence on biocompatibility, biodegradability and osteoinductive and osteoconductive potential. Objective: identify physical changes in the format, dimensions and porosity of biomaterial with new composition of wollastonite and beta tricalcium phosphate, implanted in critical bone defects in calvaria of rats. Methodology: this is an exploratory study, with a composite biomaterial before and after its implantation in vivo. Used surgical explants of rat calvarium that received biomaterial implants into the critical bone defect. The animals were divided into 3 experimental groups of random distribution, composed of 5 animals each, and evaluated for 15, 45 and 120 days. The groups were named: G0-Biomaterial; GI-15 days; GII-45 days; and, GIII-120 days. The samples were studied by micrography in scanning electronic microscope with different magnifications. It was used the free software ImageJ to image processing and particles and pores analysis. Results: the spatial distribution of the biomaterial promoted full filling of the critical bone defect. Micrographs with different magnifications allowed to identification of modifications in the area of contact between granules, decrease of the intergranular pores, increase of the area occupied by the pores and decrease of the particles in the granules. In GII, and GIII groups, it was identified formation of organic components on the surface of the implant. Conclusion: there were physical modifications in the format, horizontal dimensions, spatial distribution and porosity of the biomaterial, related to the biodegradability and the osteoinductive and osteoconductive potential of the biomaterial.


Subject(s)
Bone Regeneration
3.
Rev. Ciênc. Méd. Biol. (Impr.) ; 16(2): 151-156, out 27, 2017. fig
Article in Portuguese | LILACS | ID: biblio-1342733

ABSTRACT

Introdução: a proteção radiológica é campo do conhecimento que permeia os ambientes radiológicos. Sua aplicação envolve benefícios aos serviços, profissionais e usuários. Objetivo: identificar fatores intervenientes, bem como, dispositivos de proteção radiológica disponíveis em um serviço de medicina nuclear (MN), envolvidos nos testes de Controle de Qualidade em Câmaras Gama (CQCG). Metodologia: realizou-se um estudo observacional, do tipo exploratório e descritivo, em um serviço de MN conveniado com o Instituto Federal da Bahia (IFBA), com ênfase na proteção radiológica em testes de CQCG. A coleta de dados foi realizada em janeiro de 2016. Foram acompanhados testes diários de inspeção visual da integridade física, radiação de fundo da sala de exames, uniformidade intrínseca e centralização da largura da janela energética para cada radionuclídeo. Para os testes semanais, acompanharam-se os de resolução espacial e linearidade. Os dados foram analisados à luz da legislação/normativas vigentes para serviços de MN no Brasil. Resultados: referente à proteção radiológica em testes de CQCG, o serviço dispunha de três aventais plumbíferos e três protetores de tireóide com equivalência de 0,5mm de chumbo, além de pinças utilizadas para manipulação de fontes radioativas. Foi observada a presença de óculos de proteção, entretanto, os mesmos não eram plumbíferos. Os profissionais eram monitorados por dosímetros termoluminescentes de uso individual. Conclusão: de maneira geral, eram observados os fatores de proteção radiológica: tempo, distância e blindagem. O CQCG requer planejamento prévio com protocolo devidamente seguido que poderá minimizar a exposição ocupacional.


Introduction: radiation protection is a field of knowledge that permeates radiological environments. Its application involves benefits to services, professionals and patients. Objective: To identify intervening factors, as well as the radiological protection devices available in a nuclear medicine service (MN) involved in the Quality Control tests in Gamma Camera (CQCG). Methodology: an observational, exploratory and descriptive study was carried out at the MN service in partnership with Instituto Federal da Bahia (IFBA), with emphasis on radiological protection in CQCG tests. Data collection was performed in January 2016. Daily tests were conducted to visually inspect the physical integrity of the system, to test the background radiation of the examination room, and intrinsic uniformity and centralization of the energetic window width for each radionuclide were monitored. For the weekly tests, those of spatial resolution and linearity were monitored. The data was analyzed in accordance with the legislation/regulations for MN services in Brazil. Results: with regard to the radiological protection during CQCG tests, the service had three lead aprons and three thyroid protectors with a 0.5mm equivalence of lead, in addition, tweezers used to manipulate radioactive sources. The presence of protective goggles was observed, however, they did not contain lead. The professionals were monitored by thermoluminescent dosimeters for individual use. Conclusion: in general, the principles of radiation protection of time, distance and shielding were adopted. CQCG requires prior planning with a properly followed protocol that can minimize occupational exposure.


Subject(s)
Humans , Quality Control , Radiation Protection , Gamma Cameras , Nuclear Medicine , Epidemiology, Descriptive , Data Collection , Observational Study
SELECTION OF CITATIONS
SEARCH DETAIL