Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Rev. bras. oftalmol ; 71(1): 48-52, jan.-fev. 2012. ilus
Article in Portuguese | LILACS | ID: lil-618318

ABSTRACT

O objetivo é descrever uma nova técnica cirúrgica para fixação iriana de lente intraocular durante transplante de córnea em pacientes sem suporte capsular. A técnica de fixação iriana Tied Out Open Sky é uma técnica de fácil execução comparado com as técnicas já descritas, dispensando manobras cirúrgicas complexas, minimizando a manipulação e as complicações pós-operatórias.


To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.


Subject(s)
Humans , Female , Adult , Iris/surgery , Suture Techniques/instrumentation , Keratoplasty, Penetrating/methods , Lens Implantation, Intraocular/methods , Lenses, Intraocular , Aphakia , Polypropylenes , Biocompatible Materials , Visual Acuity , Exotropia , Lens Subluxation , Polyethylene Terephthalates , Corneal Diseases/surgery , Lens Capsule, Crystalline/pathology
2.
Rev. bras. oftalmol ; 66(5): 315-320, set.-out. 2007. ilus, graf
Article in Portuguese | LILACS | ID: lil-481149

ABSTRACT

OBJETIVO: Demonstrar o efeito e os resultados da remoção seletiva da sutura sobre o astigmatismo nos três primeiros meses de transplante de córnea pós-ceratocone. MÉTODOS: Realizamos um estudo longitudinal observacional retrospectivo, revisando aleatoriamente os prontuários médicos de 50 pacientes, submetidos à transplante penetrante de córnea por ceratocone, realizados pelo mesmo cirurgião, no período entre 2000 e 2002, no Instituto de Oftalmologia Tadeu Cvintal. Os transplantes foram realizados com a mesma técnica cirúrgica com oito pontos isolados e sutura contínua e controle ceratoscópico per-operatório. Em todas as visitas foram mensuradas a melhor acuidade visual corrigida, ceratometria e refração. A remoção seletiva da sutura e redistribuição da sutura contínua ocorreu invariavelmente no primeiro mês de pós-operatório. RESULTADOS: No primeiro mês de pós-operatório, antes do início de remoção de suturas a acuidade visual média pré-remoção foi de 0,4 log MAR. Após remoção seletiva escalonada de suturas e estabilização do astigmatismo, a acuidade visual média pós-remoção foi de 0,07 log MAR, diferença estatisticamente significativa (p< 0,0001). A ceratometria média pré-operatória foi de 2,8D, 3,8D com 30 dias de pós-operatório e de 2,8D pós-remoção de suturas e estabilização do astigmatismo com 90 dias de pós-operatório, diferenças estatisticamente significante (p = 0,0229). A redistribuição da sutura contínua foi realizada em 30 por cento dos pacientes. Obteve-se melhora da acuidade visual em 100 por cento dos pacientes. CONCLUSÃO: O transplante penetrante de córnea em pacientes portadores de ceratocone constitui uma excelente alternativa para recuperação da acuidade visual. A remoção seletiva de pontos isolados e redistribuição da sutura contínua no primeiro mês de pós-operatório promoveram melhora significativa da visão com recuperação visual precoce.


PURPOSE: To analyse the corneal astigmatism after transplantation as well as to demonstrate how post-surgical handling of sutures affects the refractive and visual outcome in patients submitted to cornea transplantation by keratoconus with three to six years of follow-up. METHODS: Non-controlled longitudinal observational secondary clinical study. Fifty records of patients submitted to penetrating keratoplasty between 2000 and 2002 have been reviewed, including 50 eyes of 50 patients operated under the same surgical technique by the same surgeon. Follow-up time ranging from three to six years. Main outcome measures were keratometry, static refraction and computadorized keratometry. Tstudent and Wilcoxon tests were used for paired samples to assess respectively possible differences between means and medians. RESULTS: The average patient age was 24.8 years. The average of the pre-visual sharpness was 0.8 log MAR and changed to 0.4 log MAR before removing the sutures and to 0.4 log MAR after the handling/removal of sutures (p< 0.0001). The topographic astigmatism varied from 2.8D before transplantation to 3.8D in the following 30 days and reached an average of 2.8 after the handling/removal of sutures (p= 0.0229). The corneal curvature changed from 51.5 to 45.2 (p= 0.0000001). 23.3 percent of the patients presented myopic and hypermetropic deviation averages of respectively -3.17D and +2.07D. 113 days was the average for the beginning of the suture removal. CONCLUSION: Although the selective and stepwise removal of sutures requires more visits of the patient to the doctor in the first months that follow the penetrating keratoplasty, the good visual and refractive results corroborate not only the importance of the post-surgical attendance, but also the identification and immediate intervention in the selective suture removal of keratoplasty.

3.
Rev. bras. oftalmol ; 66(5): 321-326, set.-out. 2007. ilus, graf, tab
Article in Portuguese | LILACS | ID: lil-481150

ABSTRACT

OBJETIVO: Avaliar a ação da ciclosporina 0,05 por cento tópica na prevenção da perda endotelial no transplante de córnea. MÉTODOS: Estudo retrospectivo de 18 olhos submetidos a transplante penetrante por ceratocone realizados no serviço pelo mesmo cirurgião. Pacientes com microscopia especular com < ou igual a 1200 células/mm², foram tratados com ciclosporina 0,05 por cento tópica (grupo A) e pacientes com microscopia especular > a 1200 células/mm² constituiram o outro grupo (grupo B). O critério de inclusão foi a presença da microscopia especular no período pós-operatório de 6 meses, 1 ano e 2 anos. Os critérios de exclusão foram retransplantes precoces, olhos contralaterais de casos bilaterais, episódios prévios de rejeição ao enxerto, doenças oculares associadas como glaucoma. A análise estatística foi realizada pelos testes de Friedman com significância estatística. Foi realizada uma avaliação da variação percentual de perda endotelial em relação à microscopia especular base, comparada aos períodos de 6 meses x 1 ano x 2 anos. RESULTADOS: No grupo A (pacientes que não utilizaram a ciclosporina 0,05 por cento) nos respectivos períodos de 6 meses, 1 ano e 2 anos, observou-se um decréscimo da variação percentual de perda endotelial estatisticamente significante (p = 0,001 ). No grupo B (pacientes que utilizaram a ciclosporina 0,05 por cento) nos respectivos períodos de 6 meses, 1 ano e 2 anos, observou-se um decréscimo da variação percentual de perda endotelial estatisticamente não significante (p = 0,513 ). CONCLUSÃO: Os resultados mostram uma desaceleração da variação percentual de perda endotelial nos transplantes penetrantes de córnea dos pacientes que utilizaram ciclosporina, quando comparados aos pacientes não tratados topicamente com tal medicação, sugerindo eficácia na manutenção das células endoteliais e sobrevida do transplante de córnea.


PURPOSE: To assess the efficacy of topical cyclosporine .05 percent for preventing endothelial loss in cornea transplant. METHODS: Retrospective study of 18 eyes submitted to penetrating transplant due to keratoconus, operation carried out by the same surgeon. Patients with specular microscopy with lower than or equal to 1200 cells/mm² belonged to the control group. The inclusion criterion was the occurrence of specular microscopy in the postoperative period over the 6- month, 1- year, and 2- year periods and the exclusion criterion was the occurrence of other pathologies, precocious retransplants, contralateral eyes of bilateral cases, previous rejection episodes, eye pathologies associated with glaucoma. The statistical analysis was based on Friedman's tests. After the application of Friedman's test to group A (patients who had not used the cyclosporine .05 percent) in the respective 6-month, 1-year, and 2-year periods, a statistically significant decrease in the percentage variation of endothelial loss was observed (p = .001). After the application of Friedman's test to group B (patients who had used the cyclosporine .05 percent) in the respective 6-month, 1-year, and 2-year periods, a statistically not significant decrease in the percentage variation of endothelial loss was observed (p = .513). RESULTS: The curves of endothelial loss went through Friedman's statistical tests in which one carried out an assessment of percentage variation of endothelial loss in relation to base specular microscopy compared to the 6 -month, 1- year, and 2-year periods. CONCLUSION: Based on the results achieved after the application of Friedman's test, one could clearly show a deceleration in the percentage variation of endothelial loss in penetrating cornea transplants of group B (patient who had used the cyclosporine .05 percent) in comparison with group A (patients who had not used the cyclosporine .05 percent), proving its beneficial effect on the...

SELECTION OF CITATIONS
SEARCH DETAIL