ABSTRACT
Background@#Immediate breast reconstruction after mastectomy can be challenging in some patients for medical or oncological reasons. Delayed two-stage tissue expander/implant breast reconstruction is a reliable option for these patients. However, data regarding surgical techniques, outcomes, and complication rates are limited. This study reports our experience using the two-stage tissue expander/implant procedure for delayed breast reconstruction. @*Methods@#This retrospective study included 32 patients (34 breasts) who underwent delayed two-stage tissue expander/implant breast reconstruction at our institution from January 2018 to July 2022. We summarized the techniques used in the procedure and evaluated the 1-year postoperative outcomes and complication rates. @*Results@#The mean time from mastectomy to expander insertion was 210±25 days, and 8.2±2.3 additional expansions were required prior to the implant insertion. The mean time of tissue expansion was 187±15 days, and the mean volume of expansion was 495±31 mL. No major complications occurred that required reoperation, and the patients were highly satisfied with the surgical results. @*Conclusions@#Although delayed two-stage tissue expander/implant breast reconstruction resulted in satisfactory outcomes, consensus regarding the operative technique is still needed. Two-stage tissue expander/implant breast reconstruction is a safe and effective option for delayed breast reconstruction.
ABSTRACT
Purpose@#Partial breast reconstruction is challenging in medially located breast cancer, particularly in terms of achieving satisfactory aesthetic coverage. Thus, we aimed to investigate surgical strategies for filling medial defects resulting from breast-conserving surgery to improve patient satisfaction and aesthetic outcomes. @*Methods@#We retrospectively evaluated 113 patients (114 cases) with medially located breast cancer between 2007 and 2018. We analysed the patient data, such as breast size, specimen weight, complications, and aesthetic results obtained using a questionnaire. @*Results@#The mean body mass index and specimen weight were 23.43 kg/m2 (range, 18.5–26.8) and 83.29 g (range, 15–290 g), respectively. The tennis racket and round-block techniques were chosen for small defects ( 30%). Hematoma was found in 1 case (0.96%), linear skin necrosis was found in 1 case (0.96%), seroma in the LD flaps was found in 8 cases (7.69%); fat necrosis in the rotational flaps was found in 2 cases (1.92%); and fat necrosis in an anterior intercostal artery perforator flap was found in 1 case (0.96%). 91 patients (87.5%) were satisfied with the aesthetic results. @*Conclusion@#The techniques used in this study for medially located breast cancer can produce fine aesthetic outcomes with regard to breast size and resection volume, with few complications.