Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Braz. oral res. (Online) ; 32: e61, 2018. tab, graf
Article in English | LILACS | ID: biblio-974452

ABSTRACT

Abstract To evaluate the impact of the GaAlAs diode laser with energy densities of 160 J/cm2, 320 J/cm2, and 640 J/cm2 on the periodontal tissues under continuous orthodontic force application and on the rate of orthodontic tooth movement in rats with type-2 diabetes mellitus. The intensity of primary alveolar bone formation was also investigated through the immune-positive osteocytes for OPN antibody. Forty adult male Wistar rats were divided into eight groups of 5 rats: normoglycemic (N), 160 J-laser-normoglycemic (160 J-LN), 320 J-laser-normoglycemic (320 J-LN), 640 J-laser-normoglycemic (640 J-LN), diabetic (D), 160 J-laser-diabetic (160 J-LD), 320 J-laser-diabetic (320 J-LD), and 640 J-laser-diabetic (640 J-LD) rats. Diabetes mellitus was induced by a single intravenous injection of 40 mg/kg monohydrated-alloxan. An orthodontic force magnitude of 20cN was applied. The laser parameters were continuous emission of 780-nm wavelength, output power of 20mW, and fiber probe with a spot size of 0.04 cm in diameter. Radiographic, histomorphological, and immunohistochemical analysis were performed after a period of 21 days. The photobiomodulation using the energy density of 640 J/cm2 strongly stimulated the alveolar bone formation and contributed the reorganization of the soft periodontal tissues, followed by the 320 J/cm2. Extensive alveolar bone loss, intense infiltration of inflammatory cells, and degradation of the PDJ tissue were mainly found in the D and 160 J-LD groups. The rate of orthodontic tooth movement was represented by the interdental distance between the cementoenamel junctions of the right mandibular first and second molars . This distance was larger in the diabetic groups (D: 39.98±1.97, 160 J-LD: 34.84±6.01, 320 J-LD: 29.82±1.73, and 640 J-LD: 35.47±4.56) than in the normoglycemic groups (N: 21.13±1.19; 160 J-LN: 22.69±0.72, 320 J-LN: 22.28±0.78, and 640 J-LN: 24.56±2.11). The number of osteopontin-positive osteocytes was significantly greater in the 640 J-LD (14.72 ± 0.82; p < 0.01) and 640 J-LN (13.62 ± 1.33; p < 0.05) groups than with D (9.82 ± 1.17) and 160 J-LD (9.77 ± 1.10) groups. Therefore, the energy density of 640 J/cm2 provided the best maintenance and integrity of the periodontal tissue microarchitecture under continuous orthodontic force when compared with the other dosages, mainly in the uncontrolled diabetic rats. The interdental distance was greater in the D and 160 J-LD groups due to presence of severe periodontitis caused by diabetes plus the mechanical stress generated by continuous orthodontic forces, implying, thus, an insufficient biostimulatory effect for the dosage of 160 J/cm2.


Subject(s)
Animals , Male , Tooth Movement Techniques/methods , Periodontium/radiation effects , Low-Level Light Therapy/methods , Diabetes Mellitus, Type 2/physiopathology , Orthodontic Appliances , Osteoclasts/radiation effects , Osteocytes/radiation effects , Osteogenesis/radiation effects , Radiation Dosage , Reference Values , Periodontium/pathology , Periodontium/diagnostic imaging , Immunohistochemistry , Radiography , Random Allocation , Reproducibility of Results , Alveolar Bone Loss/pathology , Rats, Wistar , Diabetes Mellitus, Experimental , Osteopontin/analysis , Lasers, Semiconductor/therapeutic use
2.
Dental press j. orthod. (Impr.) ; 22(4): 77-85, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-891079

ABSTRACT

ABSTRACT Introduction: Plasma-polymerized film deposition was created to modify metallic orthodontic brackets surface properties in order to inhibit bacterial adhesion. Methods: Hexamethyldisiloxane (HMDSO) polymer films were deposited on conventional (n = 10) and self-ligating (n = 10) stainless steel orthodontic brackets using the Plasma-Enhanced Chemical Vapor Deposition (PECVD) radio frequency technique. The samples were divided into two groups according to the kind of bracket and two subgroups after surface treatment. Scanning Electron Microscopy (SEM) analysis was performed to assess the presence of bacterial adhesion over samples surfaces (slot and wings region) and film layer integrity. Surface roughness was assessed by Confocal Interferometry (CI) and surface wettability, by goniometry. For bacterial adhesion analysis, samples were exposed for 72 hours to a Streptococcus mutans solution for biofilm formation. The values obtained for surface roughness were analyzed using the Mann-Whitney test while biofilm adhesion were assessed by Kruskal-Wallis and SNK test. Results: Significant statistical differences (p< 0.05) for surface roughness and bacterial adhesion reduction were observed on conventional brackets after surface treatment and between conventional and self-ligating brackets; no significant statistical differences were observed between self-ligating groups (p> 0.05). Conclusion: Plasma-polymerized film deposition was only effective on reducing surface roughness and bacterial adhesion in conventional brackets. It was also noted that conventional brackets showed lower biofilm adhesion than self-ligating brackets despite the absence of film.


RESUMO Introdução: a deposição de filme de polímero a plasma foi criada para modificar as propriedades de superfície dos braquetes ortodônticos metálicos, com o intuito de inibir a adesão bacteriana. Métodos: filmes finos de polímero de hexametildisiloxano (HMDSO) foram depositados em braquetes ortodônticos de aço inoxidável convencionais (n = 10) e autoligáveis (n = 10), utilizando a técnica de radiofrequência PECVD (Plasma-Enhanced Chemical Vapor Deposition). As amostras foram divididas em dois grupos, de acordo com o tipo de braquete, e dois subgrupos após o tratamento de superfície. A microscopia eletrônica de varredura (MEV) foi realizada para avaliar a presença de adesão bacteriana sobre as superfícies das amostras (região de ranhura horizontal e aletas) e a integridade da camada de filme. A Interferometria Confocal (CI) avaliou a rugosidade, e a molhabilidade superficial foi avaliada por goniometria. Para análise de adesão bacteriana, as amostras foram expostas durante 72 horas a uma solução de Streptococcus mutans, para formação de biofilme. Os valores obtidos para a rugosidade da superfície foram analisados pelo teste de Mann-Whitney, enquanto a adesão do biofilme foi avaliada pelos testes de Kruskal-Wallis e SNK. Resultados: observaram-se diferenças estatisticamente significativas (p <0,05) para a rugosidade superficial e redução da adesão bacteriana em braquetes convencionais após o tratamento da superfície, e entre braquetes convencionais e autoligáveis. Não foram observadas diferenças estatísticas significativas entre os grupos autoligáveis (p> 0,05). Conclusão: a deposição de polímero a plasma só foi efetiva na redução da rugosidade superficial e adesão bacteriana em braquetes convencionais. Observou-se, também, que os braquetes convencionais apresentaram menor adesão ao biofilme do que os braquetes autoligáveis, apesar da ausência de filme.


Subject(s)
Siloxanes/pharmacology , Streptococcus mutans/drug effects , Streptococcus mutans/physiology , Bacterial Adhesion/drug effects , Orthodontic Brackets/microbiology , Biofilms/drug effects , Plasma , Streptococcus mutans/isolation & purification , Surface Properties , Orthodontic Appliance Design , Polymerization
3.
Article in Portuguese | LILACS | ID: lil-583304

ABSTRACT

Introdução: A terapia com LED de baixa intensidade tem sido reportada por seu efeito analgésico e anti-inflamatório. Objetivo: Analisar a sintomatologia dolorosa após movimentação ortodôntica associada ou não à terapia não-coerente. Método: Vinte nove voluntários (19,8±7,9 anos) selecionados foram divididos em três grupos: controle (n=10), placebo (n=9) e LED (n=10, InGaAlP, 630±10nm, 14J/cm2, 0,10W, 70s). Os participantes tiveram os molares separados ortodonticamente e receberam orientação para anotar o nível de dor entre o momento da separação e 168 horas experimentais. Resultados: O grupo LED apresentou redução (p<0,01) da dor em relação aos grupos controle (2 horas) e placebo (72 horas). O grupo placebo mostrou diminuição (p<0,01) da dor em relação ao grupo controle (6h e 120 horas). Conclusão: Houve efeito positivo da fototerapia nos momentos iniciais da movimentação ortodôntica, sem variações no decorrer do período experimental.


Introduction: Therapy with low intensity LED has been reported for its analgesic and anti-inflammatory effect. Objective: Analyze the pain symptoms after orthodontic tooth movement associated or not to coherent and non-coherent phototherapy. Method: Twenty nine volunteers (19.8±7.9 years) were divided into three groups: control (n=10), placebo (n=9) and LED (n=10, InGaAlP, 630±10nm, 14 J/cm2, 0.10W, 70s). The participants? molars were orthodontically separated, and they were instructed to write down pain level using a visual analog scale between the separator placement and 168 experimental hours. Results: The LED group showed reduction in pain at two hours compared to the control group (72 hours). The placebo group presented a decrease of pain levels in relation the control group (6 and 120 hours). Conclusion: There was positive effect of phototherapy in the early stages of orthodontic movement without variation during the experimental period.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Pain/radiotherapy , Low-Level Light Therapy , Lasers, Semiconductor/therapeutic use , Orthodontics , Tooth Movement Techniques
SELECTION OF CITATIONS
SEARCH DETAIL