Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Braz. oral res ; 23(4): 439-445, Oct.-Dec. 2009. graf, tab
Article in English | LILACS | ID: lil-534216

ABSTRACT

The aim of this study was to assess the microhardness of 5 glass ionomer cements (GIC) - Vidrion R (V, SS White), Fuji IX (F, GC Corp.), Magic Glass ART (MG, Vigodent), Maxxion R (MR, FGM) and ChemFlex (CF, Dentsply) - in the presence or absence of a surface protection treatment, and after different storage periods. For each GIC, 36 test specimens were made, divided into 3 groups according to the surface protection treatment applied - no protection, varnish or nail varnish. The specimens were stored in distilled water for 24 h, 7 and 30 days and the microhardness tests were performed at these times. The data obtained were submitted to the ANOVA for repeated measures and Tukey tests (á = 5 percent). The results revealed that the mean microhardness values of the GICs were, in decreasing order, as follows: F > CF = MR > MG > V; that surface protection was significant for MR, at 24 h, without protection (64.2 ± 3.6a), protected with GIC varnish (59.6 ± 3.4b) and protected with nail varnish (62.7 ± 2.8ab); for F, at 7 days, without protection (97.8 ± 3.7ab), protected with varnish (95.9 ± 3.2b) and protected with nail varnish (100.8 ± 3.4a); and at 30 days, for F, without protection (98.8 ± 2.6b), protected with varnish (103.3 ± 4.4a) and protected with nail varnish (101 ± 4.1ab) and, for V, without protection (46 ± 1.3b), protected with varnish (49.6 ± 1.7ab) and protected with nail varnish (51.1 ± 2.6a). The increase in storage time produced an increase in microhardness. It was concluded that the different GICs, surface protection treatments and storage times could alter the microhardness values.


Subject(s)
Dental Atraumatic Restorative Treatment/methods , Dental Cavity Lining/instrumentation , Glass Ionomer Cements/chemistry , Analysis of Variance , Dental Atraumatic Restorative Treatment/instrumentation , Drug Storage/methods , Hardness Tests , Materials Testing , Surface Properties , Time Factors
2.
J. appl. oral sci ; 15(5): 459-464, Sept.-Oct. 2007. ilus, graf, tab
Article in English | LILACS | ID: lil-465931

ABSTRACT

The aim of this in vitro study was to evaluate the effect of different bur types and acid etching protocols on the shear bond strength (SBS) of a resin modified glass ionomer cement (RM-GIC) to primary dentin. Forty-eight clinically sound human primary molars were selected and randomly assigned to four groups (n=12). In G1, the lingual surface of the teeth was cut with a carbide bur until a 2.0-mm-diameter dentin area was exposed, followed by the application of RM-GIC (Vitremer - 3M/ESPE) prepared according to the manufacturer's instructions. The specimens of G2, received the same treatment of G1, however the dentin was conditioned with phosphoric acid. In groups G3 and G4 the same procedures of G1 and G2 were conducted respectively, nevertheless dentin cutting was made with a diamond bur. The specimens were stored in distilled water at 37ºC for 24h, and then tested in a universal testing machine. SBS. data were submitted to 2-way ANOVA (= 5 percent) and indicated that SBS values of RM-GIC bonded to primary dentin cut with different burs were not statistically different, but the specimens that were conditioned with phosphoric acid presented SBS values significantly higher that those without conditioning. To observe micromorphologic characteristics of the effects of dentin surface cut by diamond or carbide rotary instruments and conditioners treatment, some specimens were examined by scanning electron microscopy. Smear layer was present in all specimens regardless of the type of rotary instrument used for dentin cutting, and specimens etched with phosphoric acid presented more effective removal of smear layer. It was concluded that SBS of a RM-GIC to primary dentin was affected by the acid conditioning but the bur type had no influence.

3.
Ciênc. odontol. bras ; 10(1): 26-33, jan.-mar. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-518099

ABSTRACT

O objetivo deste estudo foi avaliar clinicamente a eficácia do tratamento de hipersensibilidade dentinária por meio dolaser AsGaAl e Nd:YAG. Foram selecionados 14 pacientes (72 dentes) da clínica de Dentística da FOSJCûUNESP que apresentavam sensibilidade dentinária aos testes táctil e evaporativo. Os pacientes foram divididos aleatoriamente emdois grupos de sete indivíduos (36 dentes), de acordo com o tipo de tratamento: laser de baixa intensidade de AsGaAl (Three Light - Clean Line) e laser de alta intensidade de Nd:YAG (Pulse Master 600IQ - American Dental Technologies). O laser AsGaAl foi ajustado em 50mW/2J, aplicado com contato, em 4 pontos na região cervical do dente: mesial, médio, distal da face vestibular e um ponto na face lingual. O laser Nd:YAG foi ajustado em 30mJ/10Hz, aplicado por varredura não contato, por 2min. Foram realizadas 4 aplicações, com intervalos de sete dias, e os pacientes atribuíam escores para os testes táctil e evaporativo realizados antes e depois da aplicação do laser. Os dados foram submetidos à análise de variância não paramétrica de Friedman e teste de comparação múltipla de Dunn (p<0,05), e demonstraramque ambos os grupos apresentaram diferença estatisticamente significante entre a condição inicial sem tratamento e a última aplicação do laser para os testes táctil e evaporativo. Concluiu-se que o laser de AsGaAl e o laser de Nd:YAG são efetivos no tratamento de hipersensibilidade dentinária e que não houve diferença significante entre os resultados obtidos entre o laser de AsGaAl e o laser de Nd:YAG.


Subject(s)
Humans , Dentin Sensitivity , Low-Level Light Therapy
4.
Pesqui. bras. odontopediatria clín. integr ; 6(3): 323-328, set.-dez. 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-455400

ABSTRACT

Objetivo: Avaliar a eficiência do uso de laser de diodo(Diagnodent 2095®, Kavo/Alemanha) no diagnóstico de lesõesde cáries oclusais comparando-o com o método visual.Método: A amostra foi composta por 39 dentes permanentes(18 molares e 21 pré-molares), que apresentavam alteraçãomacroscópica visível, podendo indicar lesão de cárie inicial,num total de 60 sítios. Dois examinadores fizeram asavaliações separadamente (visual e laser). O diagnósticovisual foi feito com a utilização de espelho bucal e luz artificial,sem sonda exploradora. Para o diagnóstico com Diagnodentforam realizadas 3 medições para cada sítio, obtendo-se umamédia. Foram excluídos os sítios classificados como hígidos, eos sítios classificados como cariados foram selecionados paraa comprovação dos métodos diagnósticos, através detratamento invasivo. Em seguida, verificou-se a real situaçãodo comprometimento tecidual através de inspeção visual porambos os examinadores. Para o cálculo do erro intraexaminadorese inter-examinadores para cada sistemadiagnóstico utilizou-se o método estatístico de kappa. O índicede concordância entre examinadores foi de k=0,82 para ométodo visual e k=0,93 para o diagnóstico com Diagnodent. Acorrespondência entre os dois métodos de diagnóstico foik=0,70 para o examinador 1 e k= 0,77 para o examinador 2. Osvalores de sensibilidade e especificidade foram calculados combase nos dados obtidos após o tratamento invasivo.Resultados: No exame visual a especificidade foi de 59,5 por cento e asensibilidade foi 88,9 por cento, enquanto com o método Diagnodent foide 69,1 por cento e 100 por cento respectivamente. Conclusão: O diagnósticocom Diagnodent é efetivo para identificação de cáries oclusaisincipientes quando comparado com o método visual, podendoser utilizado como um método auxiliar.


Subject(s)
Humans , Adolescent , Adult , Dental Caries/diagnosis , Lasers , Dental Occlusion
5.
Braz. dent. j ; 17(4): 290-295, 2006. tab, ilus
Article in English | LILACS | ID: lil-442396

ABSTRACT

The purpose of this in vitro study was to evaluate the effect of different surface treatments on the shear bond strength of a resin-based cement to porcelain. Sixty pairs of 50 percent aluminous porcelain discs were fabricated. In each pair, one disc measured 6 mm in diameter X 3 mm thickness (A) and the other measured 3 mm in diameter X 3mm thickness (B). The specimens were randomly assigned to 6 groups (n=10 pairs of discs), according to the surface treatment: etching with 10 percent hydrofluoric acid for 2 or 4min (G1 and G2); 50-æm particle aluminum oxide sandblasting for 5 s (G3); sandblasting followed by etching for 2 or 4min (G4 and G5) and control - no treatment (G6). A silane agent was applied to the treated surface of both discs of each pair. Bistite II DC dual-cure resin cement was applied and the B discs were bonded to their respective A discs. Specimens were stored in distilled water at 37°C for 24 h and were tested in shear strength at a crosshead speed of 2 mm/min. Means in MPa were: G1: 14.21 ± 4.68; G2: 8.92 ± 3.02; G3: 10.04 ± 2.37; G4: 12.74 ± 5.15; G5: 10.99 ± 3.35; G6: 6.09 ± 1.84. Data were compared by one-way ANOVA and Tukey's test at 5 percent significance level. Bond strength recorded after 2-min acid etching was significantly higher than 4-min etching (p<0.05) and control (p<0.05), but did not differ significantlyfrom sandblasting alone (p>0.05) or followed by etching for 2 or 4 min (p>0.05). Within the limitations of an in vitro study, it may be concluded that 2-min hydrofluoric acid etching produced a favorable micromechanical retention that enhanced resin cement bond strength to porcelain.


O objetivo deste estudo in vitro foi avaliar o efeito de diferentes tratamentos de superfície na resistência ao cisalhamento da união entre porcelana e cimento resinoso. Foram confeccionados sessenta pares de discos de porcelana aluminizada a 50 por cento, de 6 mm de diâmetro por 3 mm de espessura (A) e 3 mm de diâmetro por 3 mm de espessura (B). Os espécimes foram divididos aleatoriamente em 6 grupos (n=10 pares), de acordo com os tratamentos de superfície: condicionamento com ácido fluorídrico por 2 e 4 min (G1 e G2), jateamento com óxido de alumínio (50 æm) por 5 s (G3), jateamento seguido de ácido fluorídrico por 2 e 4 min (G4 e G5) e controle (G6). Em seguida, foi aplicado silano na superfície tratada de ambos os discos, e os discos B foram cimentados sobre os respectivos discos A, utilizando o cimento resinoso dual Bistite II DC. Os espécimes foram armazenados em água destilada a 37°C por 24 h, para posterior teste de cisalhamento em máquina de ensaio universal. As médias em MPa foram: G1: 14,21 ± 4,68; G2: 8,92 ± 3,02; G3: 10,04 ± 2.37; G4: 12,74 ± 5,15; G5: 10,99 ± 3,35; G6: 6,09 ± 1,84. Os dados foram submetidos à análise de variância a um critério e teste de Tukey (p<0,05). O condicionamento ácido por 2 min apresentou resultados significantemente superiores ao condicionamento por 4 min (p<0,05) e ao grupo controle (p<0,05), porém não diferiu estatisticamente do jateamento, associado ou não ao ácido fluorídrico por 2 ou 4 min (p>0,05). Dentro das limitações de um estudo in vitro, conclui-se que o condicionamento com ácido fluorídrico por 2 min produziu uma retenção micromecânica favorável, que aumentou a resistência de união entre o cimento resinoso e a porcelana.


Subject(s)
Humans , Dental Bonding , Dental Porcelain/chemistry , Resin Cements/chemistry , Acid Etching, Dental , Adhesiveness , Air Abrasion, Dental , Aluminum Oxide/chemistry , Composite Resins/chemistry , Dental Stress Analysis/instrumentation , Hydrofluoric Acid/chemistry , Materials Testing , Microscopy, Electron, Scanning , Shear Strength , Surface Properties , Silanes/chemistry , Temperature , Time Factors , Water/chemistry
6.
Ciênc. odontol. bras ; 8(3): 22-28, jul.-set. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: lil-450412

ABSTRACT

O objetivo deste trabalho in vivo foi avaliar a adaptação de apoios em cíngulo confeccionados sobre esmalte ou resina composta em Próteses Parciais Removíveis. Após a prova e ajuste da armação metálica e anteriormente ao registro da relação maxilo-mandibular foram selecionados caninos com apoios considerados adaptados clinicamente, totalizando uma amostra de 16 apoios em esmalte (Grupo A) e 16 apoios em resina composta (Grupo B). A adaptação foi verificada utilizando uma silicona por condensação leve (Heraeus Kulzer). O material foi manipulado e colocado na face interna do apoio, em seguida a armação metálica foi inserida na boca de acordo com a trajetória de inserção até a posição de assentamento final. Após a polimerização, o material adere a armação metálica que foi removida da boca. Outra silicona por condensação média (3M) foi colocada sobre o material anterior, formando o corpo-de-prova, que foi seccionado longitudinalmente na região mais profunda do preparo. Sua espessura mostrou o grau de adaptação entre a fundição e o dente suporte. As medidas foram feitas utilizando projetor de perfil (MP320- Carl Zeiss, JENA). Os resultados foram analisados através do Teste de Mann-Whitney (5%), onde foi observada uma diferença significante (p=0,017) entre os dois grupos(Grupo A= 0,584 ± 0,325mm e Grupo B= 0,311 ± 0,237mm). Os apoios confeccionados sobre resina composta apresentaram uma melhor adaptação ao preparo para apoio do que os realizados sobre esmalte.


Subject(s)
Humans , Composite Resins , Dental Abutments , Dental Enamel , Dental Materials , Denture, Partial, Removable , Statistics, Nonparametric
7.
Rev. bras. odontol ; 62(3/4): 265-268, 2005. graf, tab
Article in Portuguese | LILACS, BBO | ID: lil-541758

ABSTRACT

O objetivo deste trabalho foi verificar, por meio de validação da microdureza, a interferência de diferentes espessuras (0,1 e 2mm) de cerâmica IPS Empressll na fotopolimerização dos cimentos resinosos duais Variolink (V) e Enforce (E). As amostras foram divididas em seis grupos (n= 12) de acordo com o cimento e a espessura da barreira cerâmica: VO - sem barreira; V1 - 1mm; V2- 2mm; EO - sem barreira; E1 - 1mm; E2 - 2mm. As médias (± desvio - padrão) obtidas foram: VO - 47,88 ± 2,24; V1 - 44,42 ± 2,71; V2 - 39,15 ± 1,98; E0 - 54,70 ± 3,36; E1 - 50,34 ± 2,68; E2 - 44,16 ± 2,95. Concluiu-se que a interposição da cerâmica reduziu microdureza dos cimentos e que o Enforce apresentou uma microdureza superior ao Variolinkll.


Subject(s)
Ceramics/standards , Resin Cements/standards , Materials Testing , Dental Porcelain/standards , Hardness Tests
8.
RGO (Porto Alegre) ; 51(2): 89-94, abr.-jun. 2003. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-396990

ABSTRACT

O objetivo deste trabalho foi avaliar a rugosidade superficial de resinas compostas após imersão em meio ácido. Foram utilizadas 3 resinas compostas, divididas em 6 grupos de 10 amostras cada: G1 e G2-microparticulas (A110-3m), G3 e G4- híbridas(Z100 - 3M) e G5 e G6 - compactável (P60-3M). Os corpos-de-prova foram confeccionados a partir de uma matriz metálica cilíndrica (6mm x 3mm) onde o material foi inserido em 2 incrementos de 1,5mm de espessura. Cada extremidade do espécime foi coberta como uma matriz de poliéster (Mylar - Hawe - Neos Dental) e uma placa de vidro com 1,2 mm de espessura. As amostras foram armazenadas em água destilada a 37°C por 24 horas, e em seguida os grupos G2, G4 e G6 receberam polimento com seqüência de discos de óxido de alumínio (Soft-Lex- 3M). Foi realizada a leitura inicial de rugosidade superficial utilizando-se o rugosímetro a laser (Perthometer S8P - Perthen-Mahr). Cada corpo-de-prova recebeu 3 leituras, obtendo-se valores de rugosidade média (Ra). A seguir, os corpos-de-prova foram imersos em recepientes contendo 10ml de gel ácido (carboximetilcelulose 5 por cento; hidróxido de potássio - pH 4,5; ácido lático 0,1M) por 7 dias, e uma nova leitura rugosimétrica foi realizada. Os dados foram analisados através do teste de ANOVA e as diferenças comparadas pelo teste de Tukey (p<0,05). os valores iniciais em Ra foram: G1=0,24; G2=0,25; G3=0,20; G4=0,59; G5=0,15 e G6=0,32. Os valores finais em Ra foram; G1=0,23; G2=0,22; G3=0,20: G4=0,53; G5=0,20; e G6=0,35. Conclui-se que não houve influência na rugosidade superficial das resinas compostas após 7 dias de imersão em meio ácido, independente do polimento das mesmas


Subject(s)
Acids , Composite Resins , Dental Polishing , In Vitro Techniques
9.
JBC j. bras. clin. odontol. integr ; 6(31): 19-23, jan.-fev. 2002. ilus
Article in Portuguese | LILACS, BBO | ID: lil-336411

ABSTRACT

Overdenture ou sobredentaduras säo próteses removíveis totais ou parciais que recobrem um ou mais dentes suportes ou implantes. A preservaçäo de dentes naturais ou raízes suportes para overdentures pode ser considerada uma opçäo alternativa válida para próteses totais e parciais removíveis. Estes suportes possibilitam um retardo na reabsorçäo do osso alveolar, mantêm a propriocepçäo periodontal e a eficiência mastigatória. No entanto, parece que os dentes suportes de overdentures säo muito suscetíveis às cáries e à doença periodontal. Nesta revisäo da literatura, avaliamos a importância da manutençäo da higiene oral pelo paciente, retornos para controle e uso de flúor tópico no sucesso do tratamento com overdentures


Subject(s)
Denture, Complete , Denture, Partial, Removable , Dental Abutments , Dental Caries , Oral Hygiene , Periodontal Diseases
SELECTION OF CITATIONS
SEARCH DETAIL