Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 269-275, 2024.
Article in Chinese | WPRIM | ID: wpr-1013507

ABSTRACT

@#Objective To summarize and analyze the preliminary clinical outcomes of the KokaclipTM transcatheter edge-to-edge mitral valve repair system for severe degenerative mitral regurgitation (DMR). Methods This study was a single-arm, prospective, single-group target value clinical trial that enrolled patients who underwent the KokaclipTM transcatheter edge-to-edge repair (TEER) system for DMR in the Department of Heart Surgery of Guangdong Provincial People's Hospital, Guangdong Cardiovascular Institute from June 2022 to January 2023. Differences in the grade of mitral regurgitation (MR) during the perioperative and follow-up periods were compared, and the incidences of adverse events such as all-cause death, thoracotomy conversion, reoperation, and severe recurrence of MR during the study period were investigated. Results The enrolled patient population consisted of 14 (50.0%) females with a mean age of 70.9±5.4 years. Twenty-eight (100.0%) patients were preoperatively diagnosed with typeⅡ DMR, with a prolapse width of 12.5 (11.0, 16.1) mm, a degree of regurgitation 4+ leading to pulmonary venous reflux, and a New York Heart Association cardiac function class≥Ⅲ. All patients completed the TEER procedure successfully, with immediate postoperative improvement of MR to 0, 1+, and 2+ grade in 2 (7.1%), 21 (75.0%), and 5 (17.9%) patients, respectively. Mitral valve gradient was 2.5 (2.0, 3.0) mm Hg. Deaths, thoracotomy conversion, or device complications such as unileaflet clamping, clip dislodgement, or leaflet injury were negative. Twenty-eight (100.0%) patients completed at least 3-month postoperative follow-up with a median follow-up time of 5.9 (3.6, 6.8) months, during which patients had a mean MR grade of 1.0+ (1.0+, 2.0+) grade and a significant improvement from preoperative values (P<0.001). There was no recurrence of ≥3+ regurgitation, pulmonary venous reflux, reoperation, new-onset mitral stenosis, or major adverse cardiovascular events. Twenty-two (78.6%) patients’ cardiac function improved to classⅠorⅡ. Conclusion The domestic KokaclipTM TEER system has shown excellent preliminary clinical results in selected DMR patients with a high safety profile and significant improvement in MR. Additional large sample volume, prospective, multicenter studies, and long-term follow-up are expected to validate the effectiveness of this system in the future.

2.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 214-220, 2023.
Article in Chinese | WPRIM | ID: wpr-965729

ABSTRACT

@#Objective     To evaluate the early clinical outcomes of the Renatus® balloon-expandable valve in the treatment of severe aortic stenosis. Methods    From November 2021 to April 2022, a total of 38 patients who received Renatus® balloon-expandable valve for severe aortic stenosis in Guangdong Provincial People's Hospital were included. There were 22 males and 16 females, with an average age of 73.7±5.3 years. Mean aortic gradient and peak aortic jet velocity at baseline, post-procedure, and follow-up were compared. Clinical outcomes including all-cause mortality, perivalvular leakage, serious adverse cardiovascular events and the occurrence of permanent pacemaker implantation were assessed. Results    All patients completed the procedure successfully without conversion to thoracotomy or perioperative death. The post-implant mean aortic pressure gradient was decreased from 41.5 (27.8, 58.8) mm Hg to 6.0 (3.0, 8.0) mm Hg, and the peak aortic jet velocity was also decreased from 4.1±0.9 m/s to 1.7±0.4 m/s (P<0.001). Pacemakers were required in 2 (5.3%) patients. The median follow-up time was 27.5 (23.0, 87.5) d, with a follow-up rate of 100.0%. The mean aortic gradient was 8.0 (7.0, 10.8) mm Hg and peak aortic jet velocity was 2.0±0.3 m/s, showing significant improvement compared with those in the preoperative period (P<0.001). No severe aortic regurgitation or paravalvular leak was observed. There was no serious cardiovascular adverse event or reoperative event during the study period. Conclusion    Transcatheter aortic valve replacement with the domestic Renatus® balloon-expandable valve system is a safe and effective procedure for selected patients with severe aortic stenosis who are at high risk or not candidates for surgical aortic valve replacement.

3.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 662-666, 2022.
Article in Chinese | WPRIM | ID: wpr-934913

ABSTRACT

@#An 81-year-old male patient was admitted to Guangdong Provincial People's Hospital due to chest distress and shortness of breath after activity for half a year. Examination after admission revealed severe aortic insufficiency, tricuspid aortic valve and extremely horizontal aorta with an aortic root angulation of 99°. The Society of Thoracic Surgeons score was 7%. And taking the strong demand of the patient and his family into consideration, we decided to perform transapical transcatheter aortic valve replacement after multidisciplinary evaluation. The procedure was successfully performed by means of low deployment land zone and traction of pre-exist Prolene suture. Three-month follow-up confirmed the normal function of aortic prosthetic valve without residual regurgitation. This case provides a reference for the interventional treatment in patients with extremely horizontal aorta.

4.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 901-907, 2021.
Article in Chinese | WPRIM | ID: wpr-886532

ABSTRACT

@#Objective    To determine the clinical efficacy of transapical transcatheter mitral valve-in-valve treatment for patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement. Methods    The clinical data of 9 patients who underwent transapical transcatheter mitral valve-in-valve implantation after aortic-mitral double valve replacement due to mitral bioprosthesis deterioration from May 2020 to January 2021 in our hospital were retrospectively analyzed, including 4 males and 5 females with a mean age of 72.44±7.57 years. Results    Surgeries were performed successfully in all patients with no conversion to median sternotomy. The mean procedural time was 101.33±48.49 min, the mechanical ventilation time was 23.11±26.54 h, the ICU stay was 1.89±1.05 d and the postoperative hospital stay was 6.11±2.02 d. Residual mild mitral regurgitation was only observed in 1 patient. Only 1 patient needed postoperative blood transfusion. No major complications were observed in all patients. There was no death in postoperative 90 days. Conclusion    For patients with deteriorated mitral bioprosthesis after aortic-mitral double valve replacement, transapical transcatheter mitral valve-in-valve implantation achieves good clinical results and effectively  improves the hemodynamics without increasing the risk of postoperative left ventricular outflow tract obstruction. The surgery is feasible and effective.

5.
The Journal of Practical Medicine ; (24): 554-557, 2017.
Article in Chinese | WPRIM | ID: wpr-512871

ABSTRACT

Objective To explore the predictive value of neutrophil gelatinase associated lipocalin (NGAL) for contrast-induced acute kidney injury (CI-AKI) after emergency percutaneous coronary interventions (PCI) in patients with relative normal renal function.Methods A total of 73 patients with relative normal renal function undergoing PCI were enrolled in this prospective multicenter clinical study.Serum NGAL was measured by point-of-care test.Receiver operating characteristic (ROC) curve was used to analyze the diagnostic value of NGAL for CI-AKI.Results CI-AKI occurred in 5 patients (6.85%).The concentration of NGAL was higher in the CI-AKI group than in the non-CI-AKI group.ROC curve indicated that the area under the receiver operating characteristic was 0.755,0.761 and 0.809,respectively.Conclusions Serum NGAL at baseline,4 h and 8 h after procedure are served as a good biomarker for early diagnosis of CI-AKI after PCI.Therefore,NGAL might become an early and quick marker for CI-AKI in the future.

6.
Chinese Medical Journal ; (24): 2578-2582, 2014.
Article in English | WPRIM | ID: wpr-241619

ABSTRACT

<p><b>BACKGROUND</b>Thoracic endovascular aortic repair (TEVAR) is an emerging treatment modality, which has been rapidly embraced by clinicians treating thoracic aortic disease. However, the clinical manifestations of systemic inflammatory response after TEVAR as post-implantation syndrome (PIS) resemble the perioperative infection. This study aimed to evaluate changes and diagnostic value of procalcitonin (PCT) and other traditional inflammatory markers for infections after TEVAR.</p><p><b>METHODS</b>We conducted a prospective clinical study that enrolled 162 consecutive aortic dissection cases, who underwent TEVAR in our institution between July 2011 and November 2012. The PCT, C-response protein (CRP), erythrocyte sedimentation rate (ESR) and blood routine examination were monitored before the operation and on days 1, 2, 3 and 5 after the operation. The diagnosis of infection was confirmed by the infection control committee with reference to Hospital Acquired Infection Diagnostic Criteria Assessment, released by the Ministry of Health of the People's Republic of China.</p><p><b>RESULTS</b>Post endovascular repair of thoracic aorta, PCT changes significantly at different time points (χ(2) = 13.225, P = 0.021), without significant difference between the PIS group and the control group (0.24 ± 0.04 vs.0.26 ± 0.10, P = 0.804). PCT values were significantly higher in the first day after TEVAR than the preoperative levels (0.18 ± 0.03 vs. 0.11 ± 0.02, P < 0.001). Compared with PIS patients, the level of PCT, CRP, White blood cell (WBC) and neutrophil (NEU) in the infection patients elevated significantly (relatively χ(2) = 6.062, P = 0.048; χ(2) = 6.081, P = 0.048; χ(2) = 11.030, P = 0.004; χ(2) = 14.632, P = 0.001). According to the ROC analysis, the PCT levels in the first day after TEVAR (AUC = 0.785, P = 0.012) had better predictive values of infection than WBC, NEU CRP and ESR (AUC = 0.720, P = 0.040; AUC = 0.715, P = 0.045; AUC = 0.663, P = 0.274; AUC = 0.502, P = 0.991). The best predictive index was the changes of PCT between preoperative and postoperative (PCT), which possess AUC as 0.803 (P = 0.014). And PCT = 0.055 could be considered as an infection diagnosis cutoff value with a sensitivity of 83.3% and specificity 69.0%.</p><p><b>CONCLUSIONS</b>PCT provides better diagnostic value of infection compared with other inflammatory markers. The potential applications of PCT in differential diagnosis of PIS and infection after percutaneous TEVAR deserve further studies.</p>


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Blood Sedimentation , C-Reactive Protein , Metabolism , Calcitonin , Metabolism , Calcitonin Gene-Related Peptide , Diagnosis, Differential , Prospective Studies , Protein Precursors , Metabolism , Vascular Surgical Procedures
7.
Chinese Journal of Cardiology ; (12): 551-556, 2014.
Article in Chinese | WPRIM | ID: wpr-316413

ABSTRACT

<p><b>OBJECTIVE</b>To study the relationship between carbon dioxide combining power(CO₂-CP) and contrast-induced acute kidney injury (CI-AKI) in patients with ST segment elevation myocardial infarction and undergoing percutaneous coronary intervention.</p><p><b>METHODS</b>We retrospectively analyzed 174 patients admitted to our hospital from March 2012 to August 2013 with ST segment elevation myocardial infarction and underwent emergency percutaneous coronary intervention. Patients were divided into three tertiles according to pre-operative CO₂-CP: T1 (CO₂-CP < 22.62 mmol/L), T2(CO₂-CP 22.62-24.30 mmol/L), T3(CO₂-CP > 24.30 mmol/L). Baseline clinical data, CI-AKI incidence, in-hospital mortality and dialysis rate were compared among groups. An increase in serum creatinine of >26.4 µmol/L and/or >50% from baseline within 48 hours after contrast exposure was defined as CI-AKI. Univariate logistic regression analysis was used to identify the risk factors of CI-AKI. The relationship between CO₂-CP and CI-AKI was assessed by multivariate logistic regression analysis. Receiver operating characteristic curve was used to identify the optimal cutoff of the CO₂-CP for predicting CI-AKI.</p><p><b>RESULTS</b>CI-AKI occurred in 25 (14.4%) patients, and lower CO₂-CP was related to higher incidence of CI-AKI (27.6% (16/58) in group T1, 5.3% (3/57) in group T2, 1.7 % (1/59) in group T3, P = 0.002) and higher in-hospital mortality (10.3% (6/58) vs. 0 and 1.7% (1/59), P = 0.010). Dialysis rate was similar among 3 groups (5.2% (3/58) vs. 0 and 1.7% (1/59), P = 0.168). The incidence of CI-AKI was significantly associated with CO₂-CP < 22.00 mmol/L in univariate analyses (OR = 6.767, 95% CI 2.731-16.768, P < 0.001). After adjusting for potential confounding risk factors, CO₂-CP < 22.00 mmol/L remained significantly associated with the incidence of CI-AKI (OR = 5.835, 95%CI 1.800-18.914, P = 0.003) in multivariate logistic regression. ROC analysis revealed that the optimal cutoff of CO₂-CP to predict CI-AKI was 22.00 mmol/L (sensitivity 64.0%, specificity 79.1%, AUC = 0.714).</p><p><b>CONCLUSIONS</b>Pre-percutaneous coronary intervention CO₂-CP in patients with ST segment elevation myocardial infarction undergoing percutaneous coronary intervention is related to CI-AKI. CO₂-CP < 22.00 mmol/L predicts higher risk of CI-AKI in this patient cohort.</p>


Subject(s)
Humans , Acute Kidney Injury , Carbon Dioxide , Contrast Media , Hospital Mortality , Incidence , Kidney , Logistic Models , Myocardial Infarction , Percutaneous Coronary Intervention , ROC Curve , Retrospective Studies , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL