Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
Arq. neuropsiquiatr ; 71(5): 320-326, maio 2013. tab
Article in English | LILACS | ID: lil-674215

ABSTRACT

Coronary heart disease and ischemic stroke are frequent coexistent conditions that share risk factors and pose major burdens to global health. Even though a clear relation has been established between extracranial internal carotid artery atherosclerosis and symptomatic or asymptomatic coronary heart disease, there is a gap in knowledge about the association between intracranial atherosclerosis and coronary heart disease. Intracranial atherosclerosis is associated with high risks of stroke recurrence and vascular death. More research and clinical trials are needed to answer whether early diagnosis of asymptomatic coronary heart disease and aggressive treatment can decrease the risk of vascular death in patients with ischemic stroke caused by intracranial atherosclerosis.


A doença coronária e o acidente vascular cerebral isquêmico são condições frequentemente associadas, que compartilham fatores de risco e representam grande sobrecarga à saúde mundial. Embora seja claramente reconhecida a relação entre a doença coronária sintomática ou assintomática e a aterosclerose da artéria carótida interna em sua porção extracraniana, há uma lacuna no conhecimento sobre a associação entre doença coronária e aterosclerose intracraniana, que por sua vez é associada a alto risco de recorrência de acidente vascular cerebral isquêmico e de morte por causas vasculares. é necessário avaliar se o diagnóstico precoce da doença coronária assintomática e seu tratamento agressivo podem diminuir o risco de morte por causas vasculares em pacientes com acidente vascular cerebral isquêmico ocasionado por aterosclerose intracraniana.


Subject(s)
Humans , Coronary Disease/etiology , Intracranial Arteriosclerosis/complications , Stroke/etiology , Carotid Artery Diseases/physiopathology , Coronary Disease/diagnosis , Risk Factors , Stroke/diagnosis
3.
Rev. bras. ecocardiogr. imagem cardiovasc ; 24(1): 76-87, jan.-mar. 2011. ilus
Article in Portuguese | LILACS | ID: lil-571188

ABSTRACT

A tomografia computadorizada de multidetectores (TCMD) iniciou sua aplicação dentro da cardiologia com a quantificação de cálcio das placas coronarianas, no estudo sem contraste, por meio do escore de cálcio, mostrando um importante preditor independente de futuros eventos cardíacos. O exame com contraste endovenoso, a angiotomografia de coronárias, surgiu posteriormente como um método não invasivo para avaliação da anatomia e da doença obstrutiva coronariana, caracterizando o grau de estenose e também a presença da placa aterosclerótica não calcificada, avaliando não somente o lúmen, mas também a parede do vaso. Com o advento de novos aparelhos com mais detectores e maior resolução temporal, tem ocorrido uma redução da dose de radiação e a possibilidade de novas aplicações.


Subject(s)
Humans , Coronary Vessels , Calcium/analysis , Cardiovascular Diseases/complications , Cardiovascular Diseases/mortality , Tomography/trends , Risk Factors
4.
Arq. bras. cardiol ; 92(4): 294-301, abr. 2009. ilus, graf, tab
Article in Portuguese, English, Spanish | LILACS | ID: lil-517301

ABSTRACT

FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 por cento IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58) por cento; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78) por cento; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95 por cento IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95 por cento IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95 por cento IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.


BACKGROUND: Real-time three-dimensional echocargiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. OBJECTIVE: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. METHODS: Thirty nine consecutive patients (27 men, mean age of 57±12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95 percent CI, p<0.05. RESULTS: RT-3D-Echo measurements: LVEF ranged from 56.1 to 78.6 (65.5±5.58) percent; end-diastolic volume ranged from 49.6 to 178.2 (87±27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1±13.6) ml. CT scan measurements: LVEF ranged from 53 to 86 percent (67.8±7.78); end-diastolic volume ranged from 51 to 186 (106.5±30.3) ml; end-systolic volume ranged from 7 to 72 (35.5±13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95 percent CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95 percent CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95 percent CI 0.6673 to 0.8975). CONCLUSION: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series.


FUNDAMENTO: La ecocardiografía tridimensional en tiempo real (Eco-3DTR) y la tomografía computarizada ultrarrápida (TC ultrarrápida) son dos nuevos métodos de análisis de la fracción de eyección (FE) y de los volúmenes del ventrículo izquierdo (VI). OBJETIVO: Comparar las mediciones de la fracción de eyección del ventrículo izquierdo (FEVI) y de los volúmenes del VI apurados por la Eco-3DTR y por la TC ultrarrápida. MÉTODOS: Se estudiaron, mediante la Eco-3DTR y la TC ultrarrápida de 64 cortes, a 39 pacientes consecutivos (27 varones, promedio de edad de 57±12 años). Se analizaron: FEVI y volúmenes del VI. Análisis estadístico: coeficiente de correlación (r: Pearson), prueba de Bland & Altman, prueba de regresión lineal, 95 por ciento IC, p<0,05. RESULTADOS: Valores de la Eco-3DTR: variación de la FEVI de 56,1 a 78,6 (65,5±5,58) por ciento; variación del volumen diastólico final de 49,6 a 178,2 (87±27,8)mL; variación del volumen sistólico final de 11,4 a 78 (33,1±13,6)mL. Valores de la TC ultrarrápida: variación de la FEVI de 53 a 86 (67,8±7,78) por ciento; variación del volumen diastólico final de 51 a 186 (106,5±30,3) mL; variación del volumen sistólico final de 7 a 72 (35,5±13,4) mL. Las correlaciones entre la Eco-3DTR y la TC ultrarrápida fueron: FEVI (r: 0,7888, p<0,0001, 95 por ciento IC 0,6301 a 0,8843); volumen diastólico final (r: 0,7695, p<0,0001, 95 por ciento IC 0,5995 a 0,8730); volumen sistólico final (r: 0,8119, p<0,0001, 95 por ciento IC 0,6673 a 0,8975). CONCLUSIÓN: En esta serie, se observó una buena correlación entre las mediciones de la FEVI y entre los volúmenes ventriculares apurados por la Eco-3DTR y por la TC ultrarrápida de 64 cortes.


Subject(s)
Female , Humans , Male , Middle Aged , Coronary Artery Disease , Cardiac Volume/physiology , Echocardiography, Three-Dimensional/methods , Stroke Volume/physiology , Tomography, X-Ray Computed/methods , Ventricular Function, Left/physiology , Coronary Artery Disease , Coronary Artery Disease , Epidemiologic Methods
5.
Rev. bras. ecocardiogr ; 21(4): 23-29, out.-nov. 2008. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-497519

ABSTRACT

Fundamento e objetivo: O ecocardiograma tridimensional (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) constituem 2 novos métodos de análise da fração de ejeção e dos volumes do ventrículo esquerdo (VE). Existem poucos estudos dirigidos à comparação da análise da fração de ejeção do VE aferidos por ambos os métodos. O objetivo deste estudo foi comparar as medidas da FEVE e dos volumes do VE ECO 3D em tempo real e pela CT ultra rápida. Método: Foram estudados pelo ECO 3D e pela CT ultra rápida de 64 cortes, 41 pacientes (29 homens, média etária de 58 + - 111 anos). Foram analisados com ambas as técnicas: FEVE, volumes sistólico final e diastólico final do VE. Os parâmetros aferidos com o ECO3D e com a CT foram comparados com o emprego do coeficiente de determinação (r:Pearson), do teste de Bland & Altman e do teste de regressão linear, 95 por cento IC, p<0,05. Resultados: Medidas do ECO 3D: a FEVE variou de 56,7 a 78,9 (65,3 + - 5,7) por cento; volume diastólico final variou de 49,6 a 178,2 (88+ - 27,5) mL; volume sistólico final variou de 11,4 a 78 (33,9 + - 13,7) mL. Medidas da CT: a FEVE variou de 7 a 72 (35,1 + - 13,8) mL. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7877, p>0,0001, 95 por cento IC 0,6327 a 0,8853); volume diastólico final (r:0,7671, p< 0,0001, 95 por cento IC 0,5974 a 0,8745); volume sistólico final (r: 0,8121, p< 0,0001, 95 por cento IC 0,6659 a 0,8957). Conclusão: Foi evidenciada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D em tempo real e pela CT ultra rápida de 64 cortes.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Heart/anatomy & histology , Stroke Volume/physiology , Comparative Study , Echocardiography, Three-Dimensional/methods , Echocardiography, Three-Dimensional , Tomography/methods , Tomography
SELECTION OF CITATIONS
SEARCH DETAIL