Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
J. Bras. Patol. Med. Lab. (Online) ; 57: e4252021, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1350880

ABSTRACT

ABSTRACT Introduction: Due to urgency and demand of a response to the Covid-19 pandemic, numerous Sars-CoV-2 immunoassays have been rapidly developed. Objective: This study aimed at assessing the performance of rapid Sars-CoV-2 antibody test in comparison to high-throughput serological assays. Methods: A total of 86 serum samples were evaluated in the three assays: a lateral flow immunoassay - Wondfo Sars-CoV-2 Antibody Test (WRT) - and two chemiluminescence immunoassays: Elecsys Anti-Sars-CoV-2 (ECLIA), and Sars-CoV-2 IgG (CMIA-IgG). Results: The estimated diagnostic sensitivities of serological tests in the evaluation of serum samples from the epidemiological survey were: WRT 59% [95% confidence interval (CI) 43.4%-72.9%], ECLIA 66.7% (51%-79.4%), and CMIA-IgG 61.5% (47.1%-73%). Meanwhile, the estimated diagnostic specificity was for WRT 78.7% (95% CI 65.1%-88%), ECLIA 72.3% (58.2%-83.1%), and CMIA-IgG 76.6% (74%-95.5%). The sensitivity and specificity values were lower than manufacturers' claimed. Although 16.2% (14/86) of serological results were discordant among the three Sars-CoV-2 serological assays, the degree of agreement by the kappa index was adequate: WRT/CMIA-IgG [0.757 (95% CI 0.615-0.899)], WRT/ECLIA [0.715 (0.565-0.864)], and ECLIA/CMIA-IgG [0.858 (0.748-0.968)]. Conclusion: The serological testing may be a useful diagnostic tool, which reinforces its careful evaluation, and, as well as the correct time to use it.


RESUMEN Introducción: Debido a la urgencia y la demanda de una respuesta a la pandemia de Covid-19, se han desarrollado rápidamente numerosos inmunoensayos del Sars-CoV-2. Objetivo: Este estudio tuvo como objetivo evaluar el rendimiento de la prueba rápida de anticuerpos contra el Sars-CoV-2 en comparación con los ensayos serológicos de alto rendimiento. Métodos: Se evaluaron un total de 86 muestras de suero en los tres ensayos: un inmunoensayo de flujo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - y dos inmunoensayos de quimioluminiscencia: Elecsys Anti-Sars-CoV-2 (ECLIA) y Sars-CoV-2 IgG (CMIA-IgG). Resultados: Las sensibilidades diagnósticas estimadas de las pruebas serológicas en la evaluación de muestras de suero de la encuesta epidemiológica fueron: WRT 59% [intervalo de confianza (IC) del 95%: 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) y CMIA-IgG 61,5% (47,1%-73%). Mientras tanto, la especificidad diagnóstica estimada fue para WRT 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) y CMIA-IgG 76,6% (74%-95,5%). Los valores de sensibilidad y especificidad fueron más bajos que los declarados por los fabricantes. Aunque el 16,2% (14/86) de los resultados fueron discordantes entre los tres ensayos serológicos del Sars-CoV-2, el grado de concordancia del índice kappa fue adecuado: WRT/CMIA-IgG [0,757 (IC del 95%: 0,615-0,899)], WRT/ECLIA [0,715 (0,565-0,864)] y ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusión: La prueba serológica puede ser una herramienta diagnóstica útil, lo que refuerza su evaluación cuidadosa, así como el momento adecuado para usarla.


RESUMO Introdução: Em função da urgência e demanda de uma resposta à pandemia do novo coronavírus (Covid-19), vários testes de detecção de anticorpos para a síndrome respiratória aguda grave do coronavírus 2 (Sars-CoV-2) têm sido desenvolvidos. Objetivo: Este estudo teve como objetivo avaliar o desempenho do teste rápido utilizado em um inquérito epidemiológico para Sars-CoV-2 em comparação com outros ensaios sorológicos. Métodos: Foram avaliadas 86 amostras de soro em três ensaios sorológicos: um imunoensaio de fluxo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - e dois imunoensaios de quimioluminescência: Elecsys anti-Sars-CoV-2 (ECLIA) e Sars-CoV-2 IgG (CMIA-IgG). Resultados: As sensibilidades diagnósticas estimadas dos testes sorológicos na avaliação dessas amostras foram: TRW 59% [95% intervalo de confiança (IC) 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) e CMIA-IgG 61,5% (47,1%-73%). Enquanto isso, a especificidade diagnóstica estimada para TRW foi 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) e CMIA-IgG 76,6% (74%-95,5%). Os valores de sensibilidade e especificidade foram inferiores aos afirmados pelos fabricantes. Embora 16,2% (14/86) dos resultados tenham sido discordantes entre os três ensaios serológicos para Sars-CoV-2, o grau de concordância pelo índice Kappa foi adequado: TRW/CMIA-IgG [0,757 (95% IC 0,615-0,899)], TRW/ECLIA [0,715 (0,565-0,864)] e ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusão: O teste sorológico pode ser uma ferramenta diagnóstica útil, o que reforça sua avaliação criteriosa, bem como o momento correto de sua utilização.

2.
J. Bras. Patol. Med. Lab. (Online) ; 56: e1842020, 2020. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1134615

ABSTRACT

ABSTRACT Introduction: Many factors can impact the performance of diagnostic assays for the human immunodeficiency virus (HIV) infection, affecting the results of population surveys. Objective: The objective of this study was to evaluate the performance of point-of-care rapid tests (RT) used for HIV diagnosis as compared to conventional tests in blood samples from a population of transvestites and transsexual women. Methods: A total of 1,385 samples with HIV RT results were submitted to Instituto Adolfo Lutz for evaluation by conventional laboratory tests. Results: HIV positivity was confirmed by conventional laboratory tests in 100% of the 240 (17.3%) samples with reactive RT. However, 1,145 (82.7%) samples with non-reactive RT results were evaluated; three (0.3%) tested positive and one (0.1%), indeterminate for HIV. Although a proportion of discordant results were found, the point-of-care RTs showed a high confirmation rate when compared to the serological tests. Conclusion: The data of this study corroborate the importance of adopting effective management tools to ensure quality of HIV infection diagnosis.


RESUMEN Introducción: Muchos factores pueden impactar en el desempeño pruebas para diagnóstico de la infección por el virus de la inmunodeficiencia humana (VIH), comprometiendo los resultados de investigaciones poblacionales. Objetivo: El objetivo de este estudio fue evaluar el desempeño de pruebas rápidas (PR) en el punto de atención utilizadas para diagnosticar el VIH en relación con las pruebas convencionales en muestras de sangre de la población de travestis y mujeres transexuales en la ciudad de São Paulo, São Paulo, Brasil. Métodos: Un total de 1.385 muestras con resultados de PR de VIH se remitieron al Instituto Adolfo Lutz (IAL), para ser evaluadas por pruebas de laboratorio convencionales. Resultados: De las 240 (17,3%) muestras que presentaron resultado reactivo en las PR, positividad para VIH se confirmó en el 100% por pruebas de laboratorio convencionales. Sin embargo, de las 1.145 (82,7%) muestras evaluadas con resultado de PR non reactivo, tres (0,3%) se presentaron reactivas y una (0,1%), indeterminada para VIH. Aunque un porcentaje de resultados falsos negativos en las PR ha sido encontrado, las pruebas realizadas en el punto de atención poseen alta tasa de confirmación cuando comparadas con las pruebas serológicas. Conclusión: Los datos de este estudio resaltan la importancia de adoptar herramientas de gestión eficaces para garantizar la calidad del diagnóstico de la infección por VIH.


RESUMO Introdução: Muitos fatores podem impactar no desempenho dos testes para diagnóstico da infecção pelo vírus da imunodeficiência humana (HIV), comprometendo os resultados de pesquisas populacionais. Objetivo: O objetivo deste estudo foi avaliar o desempenho dos testes rápidos (TR) - point-of-care - utilizados para o diagnóstico do HIV em relação aos ensaios convencionais em amostras de sangue da população de travestis e mulheres transexuais da cidade de São Paulo, São Paulo, Brasil. Métodos: Ao Instituto Adolfo Lutz (IAL), 1.385 amostras com os resultados dos TR do HIV foram encaminhadas para serem avaliadas por testes laboratoriais convencionais. Resultados: Das 240 (17,3%) amostras que apresentaram resultado reagente nos TR, a positividade para HIV foi confirmada em 100% por testes laboratoriais convencionais. Entretanto, das 1.145 (82,7%) amostras com resultado de TR não reagente avaliadas, três (0,3%) apresentaram-se reagentes e uma (0,1%), indeterminada para HIV. Embora uma porcentagem de resultados falso-negativos nos TR tenha sido encontrada, os testes realizados em campo possuem alta taxa de confirmação quando comparados com os testes sorológicos. Conclusão: Os dados deste estudo ressaltam a importância da adoção de ferramentas de gestão eficazes para assegurar a qualidade do diagnóstico da infecção por HIV.

3.
Enferm. foco (Brasília) ; 10(5): 173-178, 20190000.
Article in Portuguese | LILACS, BDENF | ID: biblio-1097704

ABSTRACT

Objetivo: elaborar diretrizes para o cuidado clínico de enfermagem na assistência pré hospitalar em urgências e emergências cardiovasculares no paciente adulto. Metodologia: revisão integrativa da literatura, validação teórica, de constructo e do instrumento; neste artigo será apresentada a etapa de validação teórica realizada por juízes técnicos e de conteúdo. Resultados: obteve-se CCI acima de 0,75 assegurando a pertinência teórica, consistência, clareza, objetividade, vocabulário e aplicabilidade clínica. Resultados: obteve-se um diretriz organizada nos tópicos: avaliação das condições segurança da cena e anamnese; exame físico e condutas terapêuticas de enfermagem no APH em urgências e emergências cardiovasculares no paciente adulto. As intervenções estão direcionadas para as situações: primeiro atendimento às urgências e emergências clínicas em ambiente pré-hospitalar ou em transferências inter-hospitalares. Conclusões: constitui-se uma estratégia que pode qualificar suas intervenções junto às urgências e emergências cardiovasculares. As diretrizes elaboradas surgem como instrumento capaz de qualificar a assistência de enfermagem no APH. (AU)


Objective: to develop guidelines for clinical nursing care in prehospital care in emergencies and cardiovascular emergencies in adult patients. Methodology: integrative literature review, theoretical validation, construct and instrument; In this article the theoretical validation stage will be presented by technical judges and content. Results: ICC above 0.75 was obtained, ensuring theoretical pertinence, consistency, clarity, objectivity, vocabulary and clinical applicability. An organized guideline was obtained on the following topics: evaluation of the conditions scene safety and anamnesis; physical examination and therapeutic management of nursing in HPS in emergencies and cardiovascular emergencies in the adult patient. The interventions are directed to situations: first emergency care and clinical emergencies in a prehospital environment or in interhospital transfers. Conclusion: a strategy is formed that can qualify its interventions in the emergency and cardiovascular emergencies. The elaborated guidelines appear as an instrument capable of qualifying the nursing care in the APH. (AU)


Objetivo: elaborar directrices para el cuidado clínico de enfermería en la asistencia prehospitalaria en urgencias y emergencias cardiovasculares en el paciente adulto. Metodología: revisión integrativa de la literatura, validación teórica, de constructo y del instrumento; en este artículo se presentará la etapa de validación teórica realizada por jueces técnicos y de contenido. Resultados: se obtuvo CCI por encima de 0,75 asegurando la pertinencia teórica, consistencia, claridad, objetividad, vocabulario y aplicabilidad clínica. Se obtuvo una directriz organizada en los siguientes tópicos: evaluación de las condiciones de seguridad de la escena y anamnesis; examen físico y conductas terapéuticas de enfermería en el APH en urgencias y emergencias cardiovasculares en el paciente adulto. Las intervenciones están dirigidas a las situaciones: primera atención a las urgencias y emergencias clínicas en ambiente prehospitalario o en transferencias interhospitalarias. Conclusión: se constituye una estrategia que puede calificar sus intervenciones ante las urgencias y emergencias cardiovasculares. Las directrices elaboradas surgen como instrumento capaz de calificar la asistencia de enfermería en el APH. (AU)


Subject(s)
Evidence-Based Practice , Cardiovascular Diseases , Emergency Nursing , Evidence-Based Emergency Medicine , Evidence-Based Nursing , Nursing Care
4.
J. Bras. Patol. Med. Lab. (Online) ; 54(6): 364-371, Nov.-Dec. 2018. tab
Article in English | LILACS, SESSP-IALPROD, SES-SP | ID: biblio-975862

ABSTRACT

ABSTRACT Introduction: Early diagnosis is an important tool for strategies to fight human immunodeficiency virus (HIV) infection. Objective: The main objective of this study is to evaluate the comparability of the results of rapid tests (RT) used for the HIV diagnosis in relation to conventional molecular and serological tests in blood samples from a population of men who have sex with men (MSM), from 12 Brazilian capitals. Material and methods: 591 HIV-1 reactive test samples from 4176 MSM participants were submitted to Instituto Adolfo Lutz (IAL) for evaluation by conventional laboratory tests. From these samples with at least one RT reagent, 522 samples were analyzed, and in 493 (94.4%) the HIV positivity was confirmed, with 33% HIV-1 viral load above 5,000 copies/mL and 67% by the serological tests. A total of 336 (10%) samples with a non-reactive RT result were evaluated by standard serology, four (1.2%) tested positive for HIV. Results and conclusion: The results showed a high percentage of samples with confirmed HIV positivity in the conventional laboratory tests, as well as some non-reactive results that were confirmed positive, indicating some limitations of the RT single-step method. Therefore, the serological tests had a fundamental role in clarifying the diagnosis.


RESUMO Introdução: O diagnóstico precoce é um importante instrumento para estratégias de combate à infecção pelo vírus da imunodeficiência humana (HIV). Objetivo: O objetivo principal deste trabalho foi avaliar a comparabilidade do resultado de testes rápidos (TR) utilizados para o diagnóstico de HIV em relação a testes moleculares e sorológicos convencionais em amostras de sangue de população de homens que fazem sexo com homens (HSH) de 12 capitais brasileiras. Material e métodos: Foram encaminhadas ao Instituto Adolfo Lutz (IAL), 591 amostras com resultado reagente no TR HIV dos 4176 HSH participantes para serem avaliadas pelos testes laboratoriais convencionais. Dessas amostras com pelo menos um TR reagente, 522 amostras foram analisadas e em 493 (94,4%) confirmou-se a positividade para HIV, sendo 33% pela carga viral HIV-1 acima de 5.000 cópias/ml e 67% pelos testes sorológicos. Foram avaliadas pela sorologia convencional, 336 (10%) amostras com resultado de TR não reagente; quatro (1,2%) apresentaram-se reagentes para HIV. Resultados e conclusão: Os resultados mostraram elevado percentual de amostras com a positividade confirmada para HIV nos testes laboratoriais convencionais, bem como alguns resultados negativos que se confirmaram positivos, mostrando algumas limitações do método único do TR, destacando-se aos exames sorológicos papel fundamental à elucidação do diagnóstico.


Subject(s)
Health Strategies , Viral Load , Diagnosis , Laboratories
5.
J. Bras. Patol. Med. Lab. (Online) ; 53(4): 246-251, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-893560

ABSTRACT

ABSTRACT Introduction: Biological samples have long been used in multiple laboratory investigations, and this procedure has been an issue of concern, as the samples are submitted to repeated freeze-thaw cycles, which may affect the results of a particular immunodiagnostic assay, due to the occurrence of physical damage to the antibody of interest. Objective: This study aimed at investigating the impact of successive freeze-thaw cycles on the stability of serum samples stored at -20ºC regarding the reactivity of anti-treponemal antibodies. Methods: At the Immunology Center-Instituto Adolfo Lutz (IAL), the analyzed serum samples analyzed were prepared and established as reference material for anti-treponemal immunodiagnostic assays. Sera stability was evaluated by chemiluminescence assay in samples submitted to 25 successive freeze-thaw cycles, ranging from 6 to 174 cycles. Results: Neither statistically significant effect on the reactivity of anti-treponemal antibodies (p-value > 0.05), nor adverse effect were observed in weakly reactive samples, such as the occurrence of false-negative results. Conclusion: It was shown that 174 freeze-thaw cycles of anti-treponemal sera did not affect the stability and the quality of samples, when evaluated by chemiluminescence assay.


RESUMO Introdução: As amostras biológicas têm sido utilizadas em múltiplas investigações por um longo período de tempo, e existe a preocupação a respeito dos seus repetidos ciclos de congelamento e descongelamento que podem afetar os resultados de determinado ensaio imunodiagnóstico pela ocorrência de dano físico do anticorpo de interesse. Objetivo: O objetivo deste estudo foi investigar o impacto dos sucessivos ciclos de congelamento e descongelamento na estabilidade das amostras de soro armazenadas a -20ºC quanto à reatividade de anticorpos antitreponêmicos. Métodos: No Centro de Imunologia do Instituto Adolfo Lutz (IAL), as amostras de soro analisadas foram preparadas e estabelecidas como material de referência de teste imunodiagnóstico antitreponêmico. A estabilidade dos soros foi avaliada por meio de ensaio de quimioluminescência, em amostras submetidas a 25 sucessivos ciclos de congelamento e descongelamento, que variaram de 6 a 174 ciclos. Resultados: Não houve efeito estatisticamente significante na reatividade dos anticorpos antitreponêmicos (valor de p > 0,05), e nenhum efeito adverso foi observado nas amostras fracamente reagentes, como a ocorrência de resultados falso negativos. Conclusão: Foi demonstrado que os 174 ciclos de congelamento e descongelamento dos soros antitreponêmicos não afetaram a estabilidade e a qualidade das amostras, quando avaliados por meio do ensaio de quimioluminescência.

6.
J. Bras. Patol. Med. Lab. (Online) ; 53(3): 188-193, May.-June 2017. tab
Article in English | LILACS | ID: biblio-954367

ABSTRACT

ABSTRACT Introduction: The objective of this study was to evaluate the short-term stability of the serum samples used as internal quality control (IQC) of human immunodeficiency virus (HIV)/acquired immunodeficiency syndrome (Aids) and syphilis immunodiagnostic assays. These samples were produced at the Center of Immunology-Instituto Adolfo Lutz (IAL), and they were distributed to laboratories participating in the IAL Quality Control Program. Method: The sera analyzed by chemiluminescence assay were stored at varied temperature conditions: from 2ºC to 8ºC (refrigerator), from 15ºC to 25ºC (room temperature), at 37ºC (incubator) and at -20ºC (reference temperature) for 12 and 24 hours. Results: Comparative analysis of IQC results for anti-HIV and anti-T. pallidum (anti-treponemal) showed stability in the reference temperature and at the various simulated temperatures for transporting the samples at the established lengths of time. The data from the simple linear regression analysis of negative serum samples (incubator/24 hours) and in one batch of HIV IQC (room temperature/24 hours) were statistically significant at the level of 5% (p-value < 0.05). Conclusion: The sera presented necessary requirements as reference material to be transported to laboratories at refrigeration temperature (2ºC to 8ºC), at the maximum shipping time of 12 hours.


RESUMO Introdução: O objetivo deste estudo foi avaliar a estabilidade de curta duração de amostras de soro utilizadas como controle de qualidade interno (CQI) de testes imunodiagnósticos de vírus da imunodeficiência humana (HIV)/síndrome da imunodeficiência adquirida (Aids) e sífilis, produzidas no Centro de Imunologia do Instituto Adolfo Lutz (IAL) e distribuídas aos laboratórios participantes do Programa de Controle de Qualidade do IAL. Método: Os soros analisados por meio de ensaio de quimioluminescência foram armazenados em diferentes condições de temperaturas: de 2ºC a 8ºC (geladeira), de 15ºC a 25ºC (ambiente), 37ºC (estufa) e de -20ºC (referência) durante 12 e 24 horas. Resultados: A análise comparativa dos resultados do CQI HIV e T. pallidum (antitreponêmico) demonstrou que os materiais permaneceram estáveis, tanto na temperatura de referência quanto nas diferentes temperaturas simuladas para o transporte, no período de tempo estabelecido. No entanto, os resultados da análise de regressão linear simples das amostras de soro negativas (estufa/24 horas) e de um lote de CQI HIV (ambiente/24 horas) foram estatisticamente significativos ao nível de 5% (valor de p < 0,05). Conclusão: Os soros apresentaram requisitos necessários de material de referência para serem transportados aos laboratórios em temperatura de refrigeração (2ºC a 8ºC) no tempo máximo de 12 horas.

7.
J. Bras. Patol. Med. Lab. (Online) ; 53(1): 5-12, Jan.-Feb. 2017. graf
Article in English | LILACS | ID: biblio-893549

ABSTRACT

ABSTRACT Introduction: For conducting field studies on human immunodeficiency virus (HIV) serodiagnosis, the use of samples collected on filter paper [dried blood spot (DBS)] is profitable owing to the simplicity in handling and delivering them. Because of these characteristics, the use of DBS is recommended for studies in which the goal is to increase the population access to diagnostic testing, including HIV infection screening. For HIV diagnosis, the conventional strategy firstly uses an enzyme immunoassay as screening test, and the positive sample is confirmed on a complementary assay, as western blotting (WB). Objective: This study aimed at evaluating the analytical performance of WB assay for analyzing DSB samples. Method: One hundred eighteen blood samples collected in filter paper were analyzed by a modified WB. These samples derived from the SampaCentro Study, and they were HIV-antibody-positive in a screening test. In order to assess the reliability of these results, the assay performance was previously certified by employing the sample panel (reference panel) of Instituto Adolfo Lutz (IAL), which consisted of whole blood and plasma paired samples. Results: All of the DBS samples [100% (118/118)] showed the band pattern compatible with the criterion for HIV positivity established by the Ministry of Health. To validate the WB testing, the reciprocal relationship between antibody reactivity of DBS samples and of the respective plasma samples was investigated. Conclusion: WB optimization allowed the achievement of accurate results, and the easy DBS sample collection, transportation and storage will support the use of this immunodiagnostic technique for conducting HIV/acquired immunodeficiency syndrome (Aids) epidemiological surveys.


RESUMO Introdução: Em estudos de campo é vantajoso o emprego de amostras coletadas em papel de filtro (DBS) pela simplicidade em manuseá-las e transportá-las. Essas características colocam a tecnologia de DBS em posição de destaque nas pesquisas que buscam aumentar o acesso da população aos testes diagnósticos, incluindo os testes sorológicos para vírus da imunodeficiência humana (HIV). A estratégia convencional para o diagnóstico da infecção pelo HIV é utilizar um teste imunoenzimático como primeiro teste e, quando este for reagente, um teste complementar, como o western blot (WB), para confirmar a reatividade da amostra. Objetivo: Neste estudo foi avaliado o desempenho analítico do ensaio WB em amostras DBS. Método: As 118 amostras de sangue coletadas em papel-filtro, provenientes do estudo SampaCentro e reagentes para anticorpos anti-HIV no ensaio de triagem, foram analisadas no WB modificado. Para conferir a confiabilidade a esses resultados, o desempenho do ensaio foi previamente validado por meio de painel de amostras do Instituto Adolfo Lutz (IAL) (painel de referência), composto por amostras pareadas de sangue total e plasma. Resultados: Todas as amostras DBS [100% (118/118)] apresentaram o padrão de bandas compatível com o critério de positividade para HIV preconizado pelo Ministério da Saúde. Na validação do WB, foi averiguada a reciprocidade da reatividade dos anticorpos das amostras DBS e de suas respectivas amostras de plasma. Conclusão: A otimização do WB possibilitou a obtenção de resultados confiáveis, e a facilidade de execução, coleta, transporte e armazenamento de amostra DBS poderá viabilizar a utilização dessa técnica imunodiagnóstica em inquéritos epidemiológicos de HIV/síndrome da imunodeficiência adquirida (Aids).

8.
J. bras. patol. med. lab ; 51(2): 91-98, Mar-Apr/2015. tab, graf
Article in English | LILACS | ID: lil-748318

ABSTRACT

Introduction: Blood samples collected on filter paper (dried blood spot [DBS]) is an immunoassay that has been used for antibodies screening. Objective: To evaluate the strategy of DBS blood collection for detection of HIV antibodies, evaluation of Q-Preven HIV 1 + 2 - DBS kit lot, and to analyze the stability of DBS samples. Methods: Blood collection on DBS was performed according to World Health Organization (WHO) recommendations. The evaluation of the kit lot for HIV antibodies detection was performed using delta (d) values from the results of 774 DBS samples from volunteers men who have sex with men (MSM) recruited in the central region of São Paulo city, Brazil. Results: DBS blood collection was performed without complications. The positive (5.26) and negative (5.23) delta values allowed to clearly differentiate HIV antibodies reactive and non-reactive samples. We observed good performance of the kit lot and samples were stable on DBS form. Conclusion: Blood collection on DBS is feasible for the study of MSM population and is suitable for laboratory routine. The overall performance of Q Preven HIV-1 + 2 - DBS kit was satisfactory, having reached the quality levels required for the development of this study. .


Introdução: As amostras de sangue colhidas em papel filtro (DBS) têm sido utilizadas na triagem de anticorpos por meio de imunoensaios. Objetivos: Avaliar a estratégia de colheita de sangue em DBS para detecção de anticorpos contra o vírus da imunodeficiência humana (HIV), verificar o lote do kit Q-Preven HIV 1+2 - DBS e analisar a estabilidade das amostras DBS. Métodos: A colheita de sangue em DBS foi realizada conforme recomendações da Organização Mundial da Saúde (OMS). A avaliação do lote do kit para detecção de anticorpos anti-HIV foi feita por meio do valor de delta a partir dos resultados das 774 amostras DBS provenientes de voluntários homens que fazem sexo com homens (HSH) recrutados na região central da cidade de São Paulo, Brasil. Resultados: A colheita de sangue em DBS foi realizada sem intercorrências. O indicador delta positivo (5,26) e negativo (5,23) permitiu discriminar com clareza amostras anti-HIV reagentes e não reagentes. O lote do kit apresentou bom desempenho e as amostras permaneceram estáveis na forma de DBS. Conclusão: A colheita de sangue em DBS mostrou-se factível para o estudo realizado com a população HSH e foi adequada para a rotina laboratorial. O desempenho global do kit Q-Preven HIV 1+2 - DBS foi satisfatório, com a qualidade requerida para o desenvolvimento deste estudo. .

9.
J. bras. patol. med. lab ; 50(4): 272-277, Jul-Aug/2014. tab, graf
Article in English | LILACS | ID: lil-723972

ABSTRACT

Introduction: The antibodies have an important role in the serodiagnosis, constituting the most widely used biomarkers to detect and confirm various diseases. Objective: To investigate the reproducibility of anti-human immunodeficiency virus (HIV) antibodies reactivity, to assess the stability of the sera samples stored at -20ºC for two to eighteen years. Method: Sera were collected in the period 1988-2004 for routine anti-HIV antibodies diagnostic testing. The remaining samples stored at -20ºC, were analyzed in this study. Serum sample stability was assessed by enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), indirect immunofluorescence assay (IFA), and Western blot (WB) for detecting anti-HIV antibodies. The previously found results (1988-2004) and those obtained in 2006 were subjected to Kappa index analysis. Result: In the period 1988-to 2004, the degree of concordance of the ELISA/EIA, IFA and WB results were considered, good (k = 0.80), regular (k = 0.35), and good (k = 0.63), respectively. Conclusion: Regarding HIV serologic test, the serum samples were stable for 18 years in ELISA/EIA and for 4 years in IFA technique, however, for the WB methodology it was not possible to determine the time of stability of the anti-HIV antibodies...


Introdução: Os anticorpos possuem papel fundamental no sorodiagnóstico e constituem os mais difundidos biomarcadores empregados na detecção e na confirmação de diversas doenças. Objetivo: Verificar a reprodutibilidade dos resultados de anticorpos contra o vírus da imunodeficiência humana (HIV) para avaliar a estabilidade dos soros armazenados a -20ºC durante período de dois a dezoito anos. Método: Os soros utilizados foram provenientes de amostras remanescentes da rotina diagnóstica para detecção de anticorpos anti-HIV, no período de 1988 a 2004, os quais estavam armazenados em freezer a -20ºC. A estabilidade das amostras de soro foi avaliada por meio de enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), imunofluorescência indireta (IFI) e Western blot (WB) para detecção de anticorpos anti-HIV, e os resultados dos testes realizados anteriormente (1988-2004) e os obtidos em 2006 foram submetidos à análise do índice Kappa. Resultado: No período de 1988-2004, os graus de concordância dos resultados do ELISA/EIA, IFI e WB foram considerados, respectivamente, bom (k = 0,80), regular (k = 0,35) e bom (k = 0,63). Conclusão: No que diz respeito à sorologia para HIV, as amostras de soro foram estáveis por 18 anos no ELISA/EIA e por quatro anos na técnica de IFI, no entanto, para a metodologia de WB, não foi possível determinar o tempo de estabilidade dos anticorpos anti-HIV...


Subject(s)
Humans , Blood Banks , HIV Antibodies , Reactivity-Stability , Serum , Enzyme-Linked Immunosorbent Assay , Time Factors
10.
J. bras. patol. med. lab ; 50(1): 46-52, 02/2014. tab
Article in English | LILACS | ID: lil-704694

ABSTRACT

Introduction: The present study reports the data from the first homogeneity assessment of samples composing the serum panels produced at the Immunology Center of Instituto Adolfo Lutz, São Paulo. These samples have been distributed to the public laboratories and those partaking in the Brazilian Unified Health System, and to the participants in the Internal Quality Control Program for human immunodeficiency virus (HIV) antibody (Ab) testing. Objective: To assess the homogeneity of serum samples in panels from different lots for HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnosis by using the statistical method to ensure quality of the reference material. Method: Sera homogeneity was evaluated by means of enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) for detection of HIV Ab, and the one-way analysis of variance was employed for analyzing the data. No statistically significant differences were found among the several serum vials. Conclusion: The sera dispensed in the vials were homogeneous in the respective lots...


Introdução: No presente estudo estão descritos os resultados das primeiras análises feitas sobre a avaliação da homogeneidade das amostras componentes de painéis de soros produzidos no Centro de Imunologia do Instituto Adolfo Lutz e distribuídos aos laboratórios públicos e conveniados ao Sistema Único de Saúde e participantes do Programa de Controle de Qualidade Interno para imunodiagnóstico de vírus da imunodeficiência humana/síndrome da imunodeficiência adquirida (HIV/AIDS). Objetivo: Avaliar a homogeneidade das amostras de soro componentes de painéis de diferentes lotes para imunodiagnóstico de HIV/Aids por meio de método estatístico para garantir a qualidade do material de referência. Material e método: A homogeneidade das amostras de soro foi avaliada por meio de enzyme-linked immunoassay/enzyme immunoassay (ELISA/EIA) para detecção de anticorpos anti-HIV, e os resultados foram submetidos à análise de variância fator único. Não foram encontradas diferenças significativas entre os resultados obtidos para os diversos frascos de soro. Conclusão: As amostras distribuídas nos frascos foram homogêneas entre si nos respectivos lotes...


Subject(s)
Humans , Serum , AIDS Serodiagnosis/standards , Immunoenzyme Techniques/standards , Immunologic Tests/standards , Quality Control , Reference Standards
11.
J. bras. patol. med. lab ; 50(1): 36-45, 02/2014. tab
Article in English | LILACS | ID: lil-704696

ABSTRACT

Introduction: The use of reference materials in order to assure and perform the quality control of analytical measurements is a requirement in clinical laboratories. Objectives: Stability of serum samples, kept frozen at -20°C for long-term storage and at varied temperatures during short periods, was evaluated by investigating the persistency of anti-human immunodeficiency virus (HIV) antibodies reactivity on enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), Western blot and indirect immunofluorescence assays. Method: The analyzed sera were part of serum panels (comprised of anti-HIV positive and negative samples), produced at the Immunology Center of Instituto Adolfo Lutz, which have been the reference specimens for producing the internal quality assurance sera of HIV/acquired immunodeficiency syndrome (AIDS) immunodiagnostic assays. Sera stability was assessed in samples stored at -20°C for 56 weeks, and at various temperature conditions: from 2°C to 8°C (refrigerator), from 15°C to 25°C (room temperature), at 37°C (incubator) and at -80°C (freezer) for 24 and 48 hours. The statistical analyses on HIV-negative serum samples (long-term storage) were significant (p < 0.05), and neither adverse effects on these samples as the occurrence of false-positive results nor false-negative results in HIV antibody positive sera were found in both studies. Conclusion: It was possible to conclude that the reference material remained stable for 48 hours at different temperatures (short-term) and it remained stable at -20°C for 56 weeks (long-term)...


Introdução: A utilização de materiais de referência para assegurar e desempenhar o papel de controle de qualidade das medições analíticas é requisito em laboratórios clínicos. Objetivo: O presente estudo avaliou a estabilidade das amostras de soro, armazenadas a -20°C por um longo período de tempo e durante curto prazo em diferentes temperaturas, quanto à invariabilidade da reatividade de anticorpos contra o vírus da imunodeficiência humana (HIV), por meio de enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), Western blot e imunofluorescência indireta. Método: As amostras analisadas foram provenientes de painéis de soros (constituídos de amostras anti-HIV positivo e negativo), produzidos no Centro de Imunologia do Instituto Adolfo Lutz (IAL), os quais têm sido material de referência para o preparo de amostras do controle de qualidade interno de testes imunodiagnósticos de HIV/síndrome da imunodeficiência adquirida (AIDS). A avaliação da estabilidade dos soros foi efetuada em amostras armazenadas a -20°C por 56 semanas e nas diferentes condições de temperaturas: de 2°C a 8°C (geladeira), de 15°C a 25°C (ambiente), 37°C (estufa) e -80°C (freezer), durante 24 e 48 horas. Os resultados das análises de tendência das amostras de soro HIV negativo (armazenamento de longo prazo) foram significantes (p < 0,05) e nenhum efeito adverso foi observado nessas amostras, como a ocorrência de resultados falso-positivos, tampouco foram detectados resultados falso-negativos em amostras de soro positivas para detecção de anticorpos anti-HIV em ambas as avaliações. Conclusão: Foi possível concluir que o material de referência manteve-se estável por 48 horas nas diferentes temperaturas (curto prazo) e permaneceu estável a -20°C por 56 semanas (longo prazo)...


Subject(s)
Humans , Cold Temperature , HIV Antibodies , Hot Temperature , Quality Control , Reactivity-Stability , Serum , Temperature
12.
Rev. Inst. Adolfo Lutz ; 71(3): 573-581, jul.-set. 2012. tab, graf
Article in Portuguese | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-696270

ABSTRACT

No presente estudo foi investigado o impacto dos múltiplos ciclos de congelamento e descongelamento na estabilidade das amostras de soro estocadas a -20 °C quanto à reatividade de anticorpos anti-HIV. As amostras analisadas foram provenientes de painéis de soros (constituídos de amostras anti-HIV positivo e negativo), produzidos no Centro de Imunologia – Instituto Adolfo Lutz (IAL), os quais têm sido material de referência para o preparo de amostras do controle de qualidade interno de testes imunodiagnósticos de HIV/Aids. A avaliação da estabilidade dos soros foi efetuada por meio de ELISA/EIA, Western blote imunofluorescência indireta, em amostras submetidas a 11 consecutivos ciclos de congelamento e descongelamento, que variaram de 7 a 60 ciclos. Nenhum efeito estatisticamente significante na reatividade dos anticorpos específicos foi observado. Portanto, o procedimento de congelamento e descongelamento, em até 60 ciclos, não causou efeitos adversos na reatividade das amostras de soro positivas para detecção de anticorpos anti-HIV, sem ocorrência de reações falso-negativas, tampouco de resultados falso-positivos em amostras negativas para HIV.


Subject(s)
HIV Antibodies , Freezing , Serum , Temperature , Enzyme-Linked Immunosorbent Assay
13.
Rev. Inst. Adolfo Lutz ; 69(2): 157-164, abr.-jun. 2010. tab
Article in English | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: lil-571143

ABSTRACT

The present study reports the data resulted from the first evaluation on the performance of the laboratory units of the HIV/AIDS Diagnosis Laboratory Network of the State of São Paulo, which have agreed to participate in the Internal Quality Control scheme for HIV antibody testing (HIV-IQC) at the respective routine diagnostic services. From April 2009 to February 2010, the HIV-IQC serum panels were distributed to 37 laboratories of the Sub-Network of São Paulo State. Of these, 27 (73.0%) sent the forms back to the IAL-Central Lab with the achieved results from the IQC in HIV EIA/ELISA kits. Among 22 (59.5%) laboratories, which perform additional HIV antibody testing by indirect immunofluorescence-based assay (HIV-IFA), 11 (50.0%) carried out the HIV-IFA IQC. As identical data were reported from procedures by employing the IQC samples in different batches of EIA/ELISA kits from the same manufacturers, it may inferred that the laboratories have complied with the recommended procedures, and that the standardized conduct has been followed. Furthermore, the analyses on reported results indicated that the majority of commercial diagnostic kits used for routine HIV antibody testing at the Network laboratories show good quality and reproducibility.


No presente estudo estão descritos os resultados das primeiras análises feitas quanto ao desempenho das unidades componentes da Rede de Laboratórios de Diagnóstico de HIV/AIDS do Estado de São Paulo, que concordaram em participar da implantação do controle de qualidade interno para o diagnóstico sorológico da infecção pelo HIV (CQI-HIV) nos respectivos serviços referentes à detecção de anticorpos anti-HIV. De abril de 2009 a fevereiro de 2010 foram distribuídos os painéis de soro CQI-HIV para 37 laboratóriosda sub-rede do Estado de São Paulo. Desses, 27 (73,0%) enviaram ao IAL Central os formulários com os resultados obtidos no CQI-HIV para EIA/ELISA. Entre os 22 (59,5%) laboratórios que realizam também oensaio de IFI HIV-1 na rotina diagnóstica, 11 (50,0%) executaram o sistema CQI para esse teste. Em vistados laboratórios participantes terem apresentado idênticos dados na determinação de reatividade ideal dasamostras do painel para os conjuntos diagnósticos procedentes de mesmas firmas produtoras e de diferenteslotes, pode-se inferir que os laboratórios seguiram os procedimentos preconizados, o que demonstra aadequada execução da conduta padronizada. Ademais, a análise dos resultados obtidos indica que osconjuntos diagnósticos utilizados pela rede de laboratórios são de boa qualidade e de boa reprodutibilidade.


Subject(s)
AIDS Serodiagnosis , HIV Antibodies , HIV Infections , Quality Control
14.
Ciênc. cogn ; 15(3): 69-83, 2010.
Article in Portuguese | LILACS, INDEXPSI | ID: lil-700318

ABSTRACT

Em nossas investigações, temos como referência a noção de síntese informacional, no âmbito da representação, quando discutimos o uso de imagens no campo das ciências, tendo em vista sua relação com os fenômenos que representa e com os conceitos que tem por objetivo materializar, em nosso trabalho, nos livros didáticos do ensino de física. Abordar o estatuto das imagens no contexto do livro didático implica considerar que há um processo comunicacional elaborado por um conjunto de atores sociais que constroem representações acerca de uma determinada informação científica e que exige por parte do leitor determinadas formas de produção de sentidos no processo de construção de conhecimento. Nosso campo empírico se constitui dos livros didáticos de Física, neste trabalho, trazemos as análises de imagens de cinco produções, respectivamente, dos anos de 1910; 1920-1930; 1958; 1976; 2007. Observamos que a mudança nas práticas de ensino de ciências é acompanhada por modificações nas formas de representação das imagens e na explicação dos conceitos e fenômenos, no entanto, algumas formas se mantêm, constituindo-se na memória social do ensino de física.


Subject(s)
Memory , Knowledge , Teaching
15.
Mem. Inst. Oswaldo Cruz ; 103(8): 800-808, Dec. 2008. ilus, tab
Article in English | LILACS | ID: lil-502310

ABSTRACT

As in many areas of Brazil, the AIDS epidemic in Curitiba is relatively stable, but surveillance is important to support public policy. The molecular characteristics of HIV may be instrumental for monitoring epidemic trends. We evaluated plasma HIV-1 RNA (n = 37) from 38 cases presenting with positive serology, who were among 820 consenting volunteers visiting the downtown counselling and serology testing centre. Seroprevalence was 4.6 percent (CI 95 percent 3.2-6.3) and the estimated HIV incidence, as defined by the BED assay, was 2.86 persons/years (CI 95 percent 1.04-4.68). An additional set of contemporaneous, anonymous samples from a local laboratory was also analysed (n = 20). Regions of the HIV-1 polymerase (n = 57) and envelope (n = 34) were evaluated for subtyping, determination of mosaic structure, primary drug resistance mutations (pDRM), envelope V3 loop motifs and amino acid signatures related to viral tropism. HIV-1 clade B was observed in 53 percent of cases; HIV-1C in 30 percent and BC mosaics in 14 percent, with one F genome and one CF mosaic. Clade C infection was associated with recent infections among males (p < 0.03). Stanford surveillance pDRM was observed in 8.8 percent of sequences, with 7 percent showing high level resistance to at least one antiretroviral drug. Tropism for CXCR4 co-receptor was predicted in 18 percent of envelope sequences, which were exclusively among clade B genomes and cases with serological reactivity to chronic infection.


Subject(s)
Adult , Female , Humans , Male , Young Adult , HIV Infections/virology , HIV-1 , Base Sequence , Brazil/epidemiology , Drug Resistance, Viral/genetics , Genotype , HIV Infections/diagnosis , HIV Infections/epidemiology , Incidence , Molecular Sequence Data , Mutation , RNA, Viral/blood , RNA, Viral/genetics , Sequence Alignment , Young Adult
16.
Cad. saúde pública ; 22(9): 1979-1987, set. 2006. tab, graf
Article in Portuguese | LILACS | ID: lil-433350

ABSTRACT

A deficiência de vitamina A constitui um problema de saúde pública no Nordeste brasileiro. O objetivo deste estudo foi determinar a prevalência da deficiência de vitamina A e os fatores associados em pré-escolares de Teresina, Piauí, Brasil. Os níveis de retinol sérico foram determinados por HPLC, e foram investigadas as características sócio-econômicas e demográficas de 631 crianças com idade de 36 a 83 meses. Investigou-se a associação entre os níveis de retinol e as variáveis de interesse por análise de regressão linear uni e multivariada. O nível médio de retinol foi de 1,21mmol/L (IC95 por cento: 1,17-1,25µmol/L), independente do sexo (p = 0,259). A hipovitaminose A (retinol < 0,69µmol/L) foi observada em 15,4 por cento das crianças (IC95 por cento: 12,7-18,4), com tendência à diminuição com o avanço da idade; 29 por cento das crianças (IC95 por cento: 25,2-32,4) tinham valores aceitáveis de retinol, mas não adequados (0,70 a 1,04µmol/L). Encontrou-se associação positiva entre níveis de retinol e idade, renda per capita, suplementação prévia com vitamina A e escolaridade materna. A prevalência de hipovitaminose A representa um problema moderado de saúde pública, ressaltando a importância das estratégias de combate a essa carência na região.


Subject(s)
Humans , Child, Preschool , Vitamin A Deficiency/epidemiology , Vitamin A/administration & dosage , Chromatography, High Pressure Liquid , Prevalence , Regression Analysis , Socioeconomic Factors
17.
Article in Portuguese | LILACS, BDENF | ID: lil-490221

ABSTRACT

This study aimed at identifying initial difficulties in breastfeeding in a rooming-in care. An assessment of ninety newly-born`sucking was carried out, using UNICEF standard protocol. Observation revealed that most mother-infant pairs presented favorable behaviours towards breastfeeding, and indicatory signs of difficulties were more evident in relation to sucking and to breast response. Care in collective wards should aim at overcoming these difficulties as to facilitale the beginning of breastfeeding, thus favoring its continuity.


Este estudo objetivou identificar as dificuldades iniciais da amamentação em um alojamento conjunto. Foram avaliadas as mamadas, por meio de protocolo padronizado pelo UNICEF, de 90 recém-nascidos. Durante a observação a maioria dos binômios mãe-filho apresentava comportamentos favoráveis à amamentação e os sinais indicativos de dificuldades foram mais evidentes em relação à sucção e às respostas ao seio. O cuidado no alojamento conjunto deve visar a superação destas dificuldades de modo a facilitar o início da amamentação, favorecendo assim a sua continuidade.


Dificultades iniciales al amamantar. Este estudio tuvo por objetivo identificar las dificultades iniciales al amamantar en un alojamiento conjunto. Fueron evaluadas las mamadas, a través de protocolo patronizado por la UNICEF, de 90 recién nacidos. Mientras los observábamos, la mayoría de los binomios madre-hijo presentaban comportamientos favorables al amamantar y los señales indicativos de dificultades fueron más evidentes con relación la succión y respuestas al seno. El cuidado en el alojamiento conjunto debe llevar en cuenta la superación de estas dificultades de modo que facilite el inicio al amamantar, favoreciendo así, su continuidad.


Subject(s)
Humans , Female , Infant, Newborn , Breast Feeding , Rooming-in Care , Nursing , Infant, Newborn
18.
São Paulo; s.n; 2006. 138 p. ilus, map, tab, graf.
Thesis in Portuguese | LILACS, ColecionaSUS, SES-SP, CONASS, SESSP-CTDPROD, SES-SP, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO, SESSP-TESESESSP, SES-SP | ID: biblio-933162

ABSTRACT

O algoritmo de testes sorológicos para detecção de soroconversão recente para o HIV (STARHS) (Janssen et al., 1998) foi empregado neste estudo para discriminar infecções recentes e crônicas pelo HIV e estimar a incidência da infecção por HIV com amostras de soro provenientes de gestantes, usuários de Centro de Testagem e Aconselhamento (CTA) e indivíduos com suspeita de infecção recente pelo HIV. A associação entre os padrões de bandas presentes no teste de Western blot para HIV-1(WB) e os resultados do STARHS foi avaliada. Foram analisadas 106 amostras de soro de gestantes, 42 de usuários de CTA, 06 de soroconvertores recentes para o HIV (média de 188 dias) e 37 de indivíduos suspeitos de infecção recente pelo HIV. Estimativas de soroincidência de HIV de 0,2 (IC 95 por centos, 0,041-0,608) e 3,3 (IC 95 por cento, 1,426-6,345) por 100 amostras de soro-ano foram observadas com a análise das amostras de gestantes, de 1999 a 2002, e de usuários de CTA, de 2000 a 2001, respectivamente. Os padrões de intensidade de cor das bandas observadas na análise das amostras de soro deste estudo por meio de WB sugerem que há associação entre ausência ou intensidade baixa da banda gp41 e infecção recente [OR=16,44(IC 95%, 6,32 -42,75; p<0.001] e presença das bandas p55, p24 e p17, em intensidade de forte, e infecção crônica [OR=7,01(IC 95%, 3,05-16,14); p<0,001]... (AU)


The Serological Testing Algorithm for Recent HIV Seroconversion (STARHS) (Jansssen et al., 1998) has been employed in this study to discriminate recent and chronic HIV infections and estimate HIV incidence on HIV-positive sera samples from pregnant women (PW), Voluntary Counseling and Testing (VCT) attendees, and persons suspected to be recently infected by HIV. The association between banding patterns observed on the HIV-1 Western blot test and STARHS results was assessed. A total of 106 samples from PW, 42 samples from VCT attendees, 06 samples from HIV serconverters (mean of 188 days), and 37 samples from subjects under recent HIV-infection suspicion has been analyzed. HIVseroincidence estimates of 0.2 (95% CI, 0.041-0.608) and 3.3 (95% CI, 1.426 ­ 6.345) per 100 sera samples-years were observed for PW, from 1999-2002, and for CTA population, from 2000-2001, respectively. The patterns of color intensity of bands observed in the analysis of sera samples from this study suggest association between absence or weak reactivity at gp41 region and recent infection [OR = 16.44 (95% CI, 6.32 ­ 42.75); p<0.00], and between strong reactivities at p55, p24, and p17 bands and chronic infection [OR = 7.01(95%CI, 3.05 ­ 16.14); p<0.001]. Data from the present study suggest that the evaluation of antiHIV antibodies profiles from specimens stored in sera banks and of raw data from WB performed for HIV/Aids diagnosis could be useful on HIV incidence estimates using serological algorithms, especially when epidemiological and socio-demographic data are available. (AU)


Subject(s)
Humans , Female , Pregnancy , Pregnant Women , Anonymous Testing , Blotting, Western , HIV Infections/epidemiology
19.
São Paulo; s.n; 2006. 138 p. ilus, mapas, tab, graf.
Thesis in Portuguese | LILACS, SES-SP, CONASS, ColecionaSUS, SESSP-CTDPROD, SES-SP, SESSP-IALPROD, SES-SP, SESSP-TESESESSP, SES-SP | ID: lil-452045

ABSTRACT

O algoritmo de testes sorológicos para detecção de soroconversão recente para o HIV (STARHS) (Janssen et al., 1998) foi empregado neste estudo para discriminar infecções recentes e crônicas pelo HIV e estimar a incidência da infecção por HIV com amostras de soro provenientes de gestantes, usuários de Centro de Testagem e Aconselhamento (CTA) e indivíduos com suspeita de infecção recente pelo HIV. A associação entre os padrões de bandas presentes no teste de Western blot para HIV-1(WB) e os resultados do STARHS foi avaliada. Foram analisadas 106 amostras de soro de gestantes, 42 de usuários de CTA, 06 de soroconvertores recentes para o HIV (média de 188 dias) e 37 de indivíduos suspeitos de infecção recente pelo HIV. Estimativas de soroincidência de HIV de 0,2 (IC 95 por centos, 0,041-0,608) e 3,3 (IC 95 por cento, 1,426-6,345) por 100 amostras de soro-ano foram observadas com a análise das amostras de gestantes, de 1999 a 2002, e de usuários de CTA, de 2000 a 2001, respectivamente. Os padrões de intensidade de cor das bandas observadas na análise das amostras de soro deste estudo por meio de WB sugerem que há associação entre ausência ou intensidade baixa da banda gp41 e infecção recente [OR=16,44(IC 95%, 6,32 -42,75; p<0.001] e presença das bandas p55, p24 e p17, em intensidade de forte, e infecção crônica [OR=7,01(IC 95%, 3,05-16,14); p<0,001]...


The Serological Testing Algorithm for Recent HIV Seroconversion (STARHS) (Jansssen et al., 1998) has been employed in this study to discriminate recent and chronic HIV infections and estimate HIV incidence on HIV-positive sera samples from pregnant women (PW), Voluntary Counseling and Testing (VCT) attendees, and persons suspected to be recently infected by HIV. The association between banding patterns observed on the HIV-1 Western blot test and STARHS results was assessed. A total of 106 samples from PW, 42 samples from VCT attendees, 06 samples from HIV serconverters (mean of 188 days), and 37 samples from subjects under recent HIV-infection suspicion has been analyzed. HIVseroincidence estimates of 0.2 (95% CI, 0.041-0.608) and 3.3 (95% CI, 1.426 ­ 6.345) per 100 sera samples-years were observed for PW, from 1999-2002, and for CTA population, from 2000-2001, respectively. The patterns of color intensity of bands observed in the analysis of sera samples from this study suggest association between absence or weak reactivity at gp41 region and recent infection [OR = 16.44 (95% CI, 6.32 ­ 42.75); p<0.00], and between strong reactivities at p55, p24, and p17 bands and chronic infection [OR = 7.01(95%CI, 3.05 ­ 16.14); p<0.001]. Data from the present study suggest that the evaluation of antiHIV antibodies profiles from specimens stored in sera banks and of raw data from WB performed for HIV/Aids diagnosis could be useful on HIV incidence estimates using serological algorithms, especially when epidemiological and socio-demographic data are available. (AU)


Subject(s)
Humans , Female , Pregnancy , Pregnant Women , HIV Infections/epidemiology , Anonymous Testing , Blotting, Western
20.
J. bras. aids ; 4(2): 67-71, abr.-jun. 2003.
Article in Portuguese | LILACS, SES-SP | ID: lil-341876

ABSTRACT

O crescimento da epidemia de AIDS entre as mulheres levou, consequentemente, ao aumento do numero de casos em criancas, pois a grande maioria e devido a transmissao vertical do hiv, cuja probalidade de ocorrencia foi demonstrada em varios estudos. Foi evidenciado que a maioria dos casos, cerca de 65 porcento, ocorre durante o trabalho de parto e no parto propriamente dito e os 35 porcento restantes ocorrem intra-utero, principalmente nas ultimas semanas de gestacao; o aleitamento materno representa risco adicional de transmissao de 7 porcento a 22 porcento. A evidencia de transmissao do HIV pela amamentacao levou o Ministerio da Saude a contra-indicar o aleitamento materno por mulheres portadoras do HIV, assim como o aleitamento cruzado (feito por outra mulher). O presente artigo apresenta consideracoes sobre a utilizacao do teste rapido para pesquisa do HIV nas parturientes e sobre a importancia da supressao da lactacao nas mulheres HIV+, descrevendo os metodos que podem ser recomendados


Subject(s)
Breast Feeding , HIV , Infectious Disease Transmission, Vertical , Suppression
SELECTION OF CITATIONS
SEARCH DETAIL