Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
J. Bras. Patol. Med. Lab. (Online) ; 57: e4252021, 2021. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1350880

ABSTRACT

ABSTRACT Introduction: Due to urgency and demand of a response to the Covid-19 pandemic, numerous Sars-CoV-2 immunoassays have been rapidly developed. Objective: This study aimed at assessing the performance of rapid Sars-CoV-2 antibody test in comparison to high-throughput serological assays. Methods: A total of 86 serum samples were evaluated in the three assays: a lateral flow immunoassay - Wondfo Sars-CoV-2 Antibody Test (WRT) - and two chemiluminescence immunoassays: Elecsys Anti-Sars-CoV-2 (ECLIA), and Sars-CoV-2 IgG (CMIA-IgG). Results: The estimated diagnostic sensitivities of serological tests in the evaluation of serum samples from the epidemiological survey were: WRT 59% [95% confidence interval (CI) 43.4%-72.9%], ECLIA 66.7% (51%-79.4%), and CMIA-IgG 61.5% (47.1%-73%). Meanwhile, the estimated diagnostic specificity was for WRT 78.7% (95% CI 65.1%-88%), ECLIA 72.3% (58.2%-83.1%), and CMIA-IgG 76.6% (74%-95.5%). The sensitivity and specificity values were lower than manufacturers' claimed. Although 16.2% (14/86) of serological results were discordant among the three Sars-CoV-2 serological assays, the degree of agreement by the kappa index was adequate: WRT/CMIA-IgG [0.757 (95% CI 0.615-0.899)], WRT/ECLIA [0.715 (0.565-0.864)], and ECLIA/CMIA-IgG [0.858 (0.748-0.968)]. Conclusion: The serological testing may be a useful diagnostic tool, which reinforces its careful evaluation, and, as well as the correct time to use it.


RESUMEN Introducción: Debido a la urgencia y la demanda de una respuesta a la pandemia de Covid-19, se han desarrollado rápidamente numerosos inmunoensayos del Sars-CoV-2. Objetivo: Este estudio tuvo como objetivo evaluar el rendimiento de la prueba rápida de anticuerpos contra el Sars-CoV-2 en comparación con los ensayos serológicos de alto rendimiento. Métodos: Se evaluaron un total de 86 muestras de suero en los tres ensayos: un inmunoensayo de flujo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - y dos inmunoensayos de quimioluminiscencia: Elecsys Anti-Sars-CoV-2 (ECLIA) y Sars-CoV-2 IgG (CMIA-IgG). Resultados: Las sensibilidades diagnósticas estimadas de las pruebas serológicas en la evaluación de muestras de suero de la encuesta epidemiológica fueron: WRT 59% [intervalo de confianza (IC) del 95%: 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) y CMIA-IgG 61,5% (47,1%-73%). Mientras tanto, la especificidad diagnóstica estimada fue para WRT 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) y CMIA-IgG 76,6% (74%-95,5%). Los valores de sensibilidad y especificidad fueron más bajos que los declarados por los fabricantes. Aunque el 16,2% (14/86) de los resultados fueron discordantes entre los tres ensayos serológicos del Sars-CoV-2, el grado de concordancia del índice kappa fue adecuado: WRT/CMIA-IgG [0,757 (IC del 95%: 0,615-0,899)], WRT/ECLIA [0,715 (0,565-0,864)] y ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusión: La prueba serológica puede ser una herramienta diagnóstica útil, lo que refuerza su evaluación cuidadosa, así como el momento adecuado para usarla.


RESUMO Introdução: Em função da urgência e demanda de uma resposta à pandemia do novo coronavírus (Covid-19), vários testes de detecção de anticorpos para a síndrome respiratória aguda grave do coronavírus 2 (Sars-CoV-2) têm sido desenvolvidos. Objetivo: Este estudo teve como objetivo avaliar o desempenho do teste rápido utilizado em um inquérito epidemiológico para Sars-CoV-2 em comparação com outros ensaios sorológicos. Métodos: Foram avaliadas 86 amostras de soro em três ensaios sorológicos: um imunoensaio de fluxo lateral - Wondfo Sars-CoV-2 Antibody Test (TRW) - e dois imunoensaios de quimioluminescência: Elecsys anti-Sars-CoV-2 (ECLIA) e Sars-CoV-2 IgG (CMIA-IgG). Resultados: As sensibilidades diagnósticas estimadas dos testes sorológicos na avaliação dessas amostras foram: TRW 59% [95% intervalo de confiança (IC) 43,4%-72,9%], ECLIA 66,7% (51%-79,4%) e CMIA-IgG 61,5% (47,1%-73%). Enquanto isso, a especificidade diagnóstica estimada para TRW foi 78,7% (95% CI 65,1%-88%), ECLIA 72,3% (58,2%-83,1%) e CMIA-IgG 76,6% (74%-95,5%). Os valores de sensibilidade e especificidade foram inferiores aos afirmados pelos fabricantes. Embora 16,2% (14/86) dos resultados tenham sido discordantes entre os três ensaios serológicos para Sars-CoV-2, o grau de concordância pelo índice Kappa foi adequado: TRW/CMIA-IgG [0,757 (95% IC 0,615-0,899)], TRW/ECLIA [0,715 (0,565-0,864)] e ECLIA/CMIA-IgG [0,858 (0,748-0,968)]. Conclusão: O teste sorológico pode ser uma ferramenta diagnóstica útil, o que reforça sua avaliação criteriosa, bem como o momento correto de sua utilização.

2.
J. Bras. Patol. Med. Lab. (Online) ; 53(4): 246-251, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-893560

ABSTRACT

ABSTRACT Introduction: Biological samples have long been used in multiple laboratory investigations, and this procedure has been an issue of concern, as the samples are submitted to repeated freeze-thaw cycles, which may affect the results of a particular immunodiagnostic assay, due to the occurrence of physical damage to the antibody of interest. Objective: This study aimed at investigating the impact of successive freeze-thaw cycles on the stability of serum samples stored at -20ºC regarding the reactivity of anti-treponemal antibodies. Methods: At the Immunology Center-Instituto Adolfo Lutz (IAL), the analyzed serum samples analyzed were prepared and established as reference material for anti-treponemal immunodiagnostic assays. Sera stability was evaluated by chemiluminescence assay in samples submitted to 25 successive freeze-thaw cycles, ranging from 6 to 174 cycles. Results: Neither statistically significant effect on the reactivity of anti-treponemal antibodies (p-value > 0.05), nor adverse effect were observed in weakly reactive samples, such as the occurrence of false-negative results. Conclusion: It was shown that 174 freeze-thaw cycles of anti-treponemal sera did not affect the stability and the quality of samples, when evaluated by chemiluminescence assay.


RESUMO Introdução: As amostras biológicas têm sido utilizadas em múltiplas investigações por um longo período de tempo, e existe a preocupação a respeito dos seus repetidos ciclos de congelamento e descongelamento que podem afetar os resultados de determinado ensaio imunodiagnóstico pela ocorrência de dano físico do anticorpo de interesse. Objetivo: O objetivo deste estudo foi investigar o impacto dos sucessivos ciclos de congelamento e descongelamento na estabilidade das amostras de soro armazenadas a -20ºC quanto à reatividade de anticorpos antitreponêmicos. Métodos: No Centro de Imunologia do Instituto Adolfo Lutz (IAL), as amostras de soro analisadas foram preparadas e estabelecidas como material de referência de teste imunodiagnóstico antitreponêmico. A estabilidade dos soros foi avaliada por meio de ensaio de quimioluminescência, em amostras submetidas a 25 sucessivos ciclos de congelamento e descongelamento, que variaram de 6 a 174 ciclos. Resultados: Não houve efeito estatisticamente significante na reatividade dos anticorpos antitreponêmicos (valor de p > 0,05), e nenhum efeito adverso foi observado nas amostras fracamente reagentes, como a ocorrência de resultados falso negativos. Conclusão: Foi demonstrado que os 174 ciclos de congelamento e descongelamento dos soros antitreponêmicos não afetaram a estabilidade e a qualidade das amostras, quando avaliados por meio do ensaio de quimioluminescência.

3.
J. Bras. Patol. Med. Lab. (Online) ; 53(3): 188-193, May.-June 2017. tab
Article in English | LILACS | ID: biblio-954367

ABSTRACT

ABSTRACT Introduction: The objective of this study was to evaluate the short-term stability of the serum samples used as internal quality control (IQC) of human immunodeficiency virus (HIV)/acquired immunodeficiency syndrome (Aids) and syphilis immunodiagnostic assays. These samples were produced at the Center of Immunology-Instituto Adolfo Lutz (IAL), and they were distributed to laboratories participating in the IAL Quality Control Program. Method: The sera analyzed by chemiluminescence assay were stored at varied temperature conditions: from 2ºC to 8ºC (refrigerator), from 15ºC to 25ºC (room temperature), at 37ºC (incubator) and at -20ºC (reference temperature) for 12 and 24 hours. Results: Comparative analysis of IQC results for anti-HIV and anti-T. pallidum (anti-treponemal) showed stability in the reference temperature and at the various simulated temperatures for transporting the samples at the established lengths of time. The data from the simple linear regression analysis of negative serum samples (incubator/24 hours) and in one batch of HIV IQC (room temperature/24 hours) were statistically significant at the level of 5% (p-value < 0.05). Conclusion: The sera presented necessary requirements as reference material to be transported to laboratories at refrigeration temperature (2ºC to 8ºC), at the maximum shipping time of 12 hours.


RESUMO Introdução: O objetivo deste estudo foi avaliar a estabilidade de curta duração de amostras de soro utilizadas como controle de qualidade interno (CQI) de testes imunodiagnósticos de vírus da imunodeficiência humana (HIV)/síndrome da imunodeficiência adquirida (Aids) e sífilis, produzidas no Centro de Imunologia do Instituto Adolfo Lutz (IAL) e distribuídas aos laboratórios participantes do Programa de Controle de Qualidade do IAL. Método: Os soros analisados por meio de ensaio de quimioluminescência foram armazenados em diferentes condições de temperaturas: de 2ºC a 8ºC (geladeira), de 15ºC a 25ºC (ambiente), 37ºC (estufa) e de -20ºC (referência) durante 12 e 24 horas. Resultados: A análise comparativa dos resultados do CQI HIV e T. pallidum (antitreponêmico) demonstrou que os materiais permaneceram estáveis, tanto na temperatura de referência quanto nas diferentes temperaturas simuladas para o transporte, no período de tempo estabelecido. No entanto, os resultados da análise de regressão linear simples das amostras de soro negativas (estufa/24 horas) e de um lote de CQI HIV (ambiente/24 horas) foram estatisticamente significativos ao nível de 5% (valor de p < 0,05). Conclusão: Os soros apresentaram requisitos necessários de material de referência para serem transportados aos laboratórios em temperatura de refrigeração (2ºC a 8ºC) no tempo máximo de 12 horas.

SELECTION OF CITATIONS
SEARCH DETAIL