Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
RFO UPF ; 18(2): 165-169, Mai.-Ago. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-720736

ABSTRACT

Objetivo: avaliar a precisão dimensional de modelos de gesso obtidos em moldes de hidrocoloide irreversível contendo agente antimicrobiano, manipulado com água ou solução aquosa de digluconato de clorexidina 0,2%. Materiais e método: para as medições das dimensões lineares, foram utilizados moldes de hidrocoloide irreversível de um modelo mestre de aço inox, simulando preparos de uma prótese fixa com dois pilares separados por um espaço protético. Com esses moldes, obteve-se vinte modelos de gesso designados aos grupos: controle - modelos de gesso obtidos em moldes de hidrocoloide irreversível contendo clorexidina no pó manipulado com água destilada (n = 10); experimental - modelos de gesso obtidos em moldes de hidrocoloide irreversível contendo clorexidina no pó e manipulado com solução de clorexidina em substituição à água (n = 10). As distâncias entre pilares e os diâmetros dos pilares foram mensuradas com paquímetro digital e os dados, submetidos ao teste t student. Resultado: as medições das distâncias entre pilares e do diâmetro dos pilares dos modelos do grupo experimental não resultaram em diferenças dimensionais estatisticamente significantes quando comparadas com as do grupo controle (p > 0,05). Conclusão: de acordo com os resultados deste estudo e considerando as suas limitações, pôde-se concluir que as diferenças dimensionais entre modelos de gesso obtidos com moldes de hidrocoloide irreversível manipulado com água ou com solução aquosa de digluconato de clorexidina a 0,2% não foram estatisticamente significantes.


Objective: to assess the dimensional accuracy of plaster casts obtained from irreversible hydrocolloid impressions containing anti-microbial agent, which was mixed with either water or 0.2% chlorhexidine digluconate aqueous solution. Materials and method: the linear dimensions were measured with irreversible hydrocolloid impressions of a stainless steel master cast simulating cavity preparations for a fixed prosthesis with two abutments separated by a prosthetic space. From these molds, twenty plaster casts were made and assigned to the following groups: control - plaster casts obtained from irreversible hydrocolloid impressions made with powder containing chlorhexidine, and manipulated with distilled water (n = 10); experimental - plaster casts obtained from irreversible hydrocolloid impressions made with powder containing chlorhexidine, and manipulated with chlorhexidine solution instead of water (n = 10). The distances between the abutments and their diameters were measured with a digital caliper and data were submitted to the Student's t test. Result: there were no statistically significant differences in the measurements of distances between the abutments and their diameter in the experimental group when compared to the measurements of the control group (p > 0.05). Conclusion: according to the results of this study and considering its limitations, the dimensional differences between plaster casts obtained from irreversible hydrocolloid impressions manipulated with either water or 0.2% chlorhexidine digluconate were not statistically different.

SELECTION OF CITATIONS
SEARCH DETAIL