Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Rev. bras. cir. cardiovasc ; 39(1): e20230111, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1521673

ABSTRACT

ABSTRACT Introduction: Systemic inflammatory response syndrome (SIRS) is related to increased circulating endothelial microparticles (EMP). Objective: The aim of this study was to compare the plasma concentration of EMP between patients undergoing aortic valve replacement with conventional bioprosthesis implantation and Perceval™ S (LivaNova) and to evaluate its impact on the inflammatory response in the short-term follow-up. Methods: This is a randomized clinical trial with 24 patients submitted to isolated aortic valve replacement divided into two groups: Perceval™ S (Group P) and conventional bioprostheses (Group C). Incidence of severe SIRS (three or more criteria) in the first 48 hours postoperatively, EMP release profile, interleukins (IL) 6 and 8, C-reactive protein, and procalcitonin were analyzed preand postoperatively at 24 hours and three months. Results: There were 24 patients (12 in each group), mean age was 69.92±5.17 years, 83.33% were female, the incidence of severe SIRS was 66.7% and 50% in groups C and P, respectively (P=0.68), and EMP showed a significant increase in the 24-hour postoperative period (P≤0.001) and subsequent decrease in the three-month postoperative period (P≤0.001), returning to baseline levels. For IL-6 and IL-8, there was a greater increase in group C at 24 hours postoperatively (P=.0.02 and P<0.001). Conclusion: The incidence of severe SIRS was similar in both groups, with significantly higher levels of IL-6 and IL-8, at the 24-hour postoperative period, in group C, however with higher levels of EMP in group P, and subsequent return to baseline levels at the three-month postoperative period in both groups.

2.
Rev. bras. cir. cardiovasc ; 33(5): 476-482, Sept.-Oct. 2018. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-977453

ABSTRACT

Abstract Objective: Elaboration and internal validation of the Quality of Life in Cardiovascular Surgery (QLCS) questionnaire adapted to the reality of Brazilian cardiovascular surgery. Methods: Cross-sectional pilot study of a prospective cohort included in the Documentation and Surgical Registry Center (CEDREC) for internal validation of the QLCS questionnaire. Four hundred forty-five patients submitted to cardiovascular surgery and who answered a QLCS questionnaire 30 days after hospital discharge were included. It was applied via telephone. To verify the questions' internal consistency, Cronbach's alpha was used. The total QLCS score was calculated as the sum of 5 questions, ranging from 5 to 25 points. Mann-U-Whitney test was used to relate the symptoms with the quality of life (QoL). Level of significance was 5%. Results: After 30 days of surgery, about 95% of the patients had already returned to normal routine and 19% of them were already performing physical activity. In the evaluation of the QLCS's internal consistency, a Cronbach's alpha of 0.74 was found, suggesting that this was probably an adequate questionnaire to evaluate QoL in this population. In the comparison between the presence and absence of symptoms and the median of QoL, the presence of pain at the incision (P=0.002), chest pain (P<0.001), shortness of breath (P<0.001), and return to physical activity (P<0.001) were statistically significant. Conclusion: The process of elaboration and validation of questionnaires includes a series of steps. The QLCS questionnaire is probably an adequate tool for the evaluation of QoL in the postoperative patient of cardiovascular surgery, in this first stage of internal validation.


Subject(s)
Humans , Male , Female , Middle Aged , Quality of Life , Cardiovascular Surgical Procedures/psychology , Surveys and Questionnaires , Pilot Projects , Cross-Sectional Studies , Prospective Studies
3.
Rev. bras. cir. cardiovasc ; 33(2): 189-193, Mar.-Apr. 2018. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-958396

ABSTRACT

Abstract Introduction: The great saphenous vein is widely used as a graft in coronary artery bypass grafting surgery. Complications due to saphenous vein harvesting can be minimized when using ultrasonography mapping and marking. Objective: To analyze by clinical trial the use of vascular ultrasonography to map the saphenous vein in coronary artery bypass grafting to determine viability and dissection site. Methods: A total of 151 consecutive patients submitted to coronary artery bypass surgery with the use of the great saphenous vein as a graft were selected for this prospective study. They were divided into two groups: Group 1 - 84 patients were submitted to ultrasonographic mapping and marking of the saphenous vein; Group 2 - 67 patients had saphenous vein harvested without any previous study. Both groups were coupled with follow-up on the 1st, 5th and 30th postoperative days. Primary endpoints were need for incision of the contralateral leg and wound complications within 30 days. Results: Both legs had to be incised in 6 (8.95%) patients from Group 2 (P=0.0067). Wound complications occurred in 33 (23.4%) patients within 30 days, 21 (35%) from Group 2 e 12 (14.8%) from Group 1 (OR 3.095, 1.375-6.944, CI 95%, P=0.008). Within 30 days there were 4 (2.8%) deaths, all in Group 2 (P=0.036). Conclusion: The use of vascular ultrasonography for mapping of the great saphenous vein in coronary artery bypass surgery has properly identified and evaluated the saphenous vein, significantly reducing wound complications and unnecessary incisions. It would be advisable to use this noninvasive and easy to use method routinely in coronary artery bypass surgery.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Saphenous Vein/transplantation , Saphenous Vein/diagnostic imaging , Coronary Artery Bypass/methods , Ultrasonography, Doppler/methods , Tissue and Organ Harvesting/methods , Postoperative Complications , Surgical Wound Infection , Time Factors , Prospective Studies , Reproducibility of Results , Ultrasonography, Doppler/adverse effects , Statistics, Nonparametric , Tissue and Organ Harvesting/adverse effects
4.
Rev. bras. cir. cardiovasc ; 33(1): 32-39, Jan.-Feb. 2018. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-897981

ABSTRACT

Abstract Introduction: Active infective endocarditis is associated with high morbidity and mortality. Surgery is indicated in high-risk conditions, and the main determinants of mortality in surgical treatment should be evaluated. Objective: To identify mortality predictors in the surgical treatment of active infective endocarditis in a long-term follow-up. Methods: This prospective observational study involved 88 consecutive patients diagnosed with active infective endocarditis, who underwent surgery between January 2005 and December 2015. Fifty-eight (65.9%) patients were male, the mean age was 50.87±16.15 years. A total of 31 (35.2%) patients had a history of rheumatic fever; 48 (54.5%) had had heart surgery with prosthetic valve implantation; 45 (93.8%) had biological prosthetic valve endocarditis and 3 (6.3%) mechanical prosthetic valve; 40 (45.5%) patients had the disease in their native valve. The mean EuroSCORE II was 8.9±6.5%, and the main surgical indication was refractory heart failure in 38 (43.2%) patients. A total of 68 bioprosthesis (36 aortic, 32 mitral) and 29 mechanical prostheses (12 aortic, 17 mitral) were implanted and three mitral valve plasties performed. A total of 25 (28.4%) patients underwent double or triple valve procedures. Aortic annulus reconstruction by abscess was performed in 18 (20.5%) and six (6.81%) patients had combined procedure. The mean surgery time was 359±97.6 minutes. Results: The overall survival in up to a 10-year follow-up period was 79.5%. In the univariate analysis, the main mortality predictors were positive blood cultures (P=0.003), presence of typical microorganisms (P=0.008), most frequently Streptococcus viridans (12 cases; 25%); C-reactive protein (hazard ratio [HR] 1.034, 95% confidence interval [CI] 1.000 to 1.070, P=0.04); creatinine clearance (HR 0.977, 95% CI 0.962 to 0.993, P=0.005); length of surgery: every five minutes multiplies the chance of death 1.005-fold (HR 1.005, 95% CI 1.001 to 1.009, P=0.0307); age (HR 1.060, 95% CI 1.026 to 1.096, P=0.001); and EuroSCORE II (HR 1.089, 95% CI 1.030 to 1.151, P=0.003). Conclusion: A positive blood culture with typical microorganism, C-reactive protein, age, EuroSCORE II, total surgical time and the presence of postoperative complications were the major predictors of mortality and significantly impacted survival in up to a 10-year follow-up period.


Subject(s)
Humans , Male , Female , Middle Aged , Heart Valve Prosthesis , Endocarditis/surgery , Endocarditis/mortality , Prospective Studies , Follow-Up Studies , Treatment Outcome
5.
Rev. bras. cir. cardiovasc ; 31(4): 275-280, July-Sept. 2016. tab, graf
Article in English | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-829736

ABSTRACT

Abstract Introduction: Replacement of the aortic valve in patients with a small aortic annulus is associated with increased morbidity and mortality. A prosthesis-patient mismatch is one of the main problems associated with failed valves in this patient population. Objective: To evaluate the long-term mortality predictors in patients with a small aortic annulus undergoing aortic valve replacement with a bioprosthesis. Methods: In this retrospective observational study, a total of 101 patients undergoing aortic valve replacement from January 2000 to December 2010 were studied. There were 81 (80.19%) women with a mean age of 52.81±18.4 years. Severe aortic stenosis was the main indication for surgery in 54 (53.4%) patients. Posterior annulus enlargement was performed in 16 (15.8%) patients. Overall, 54 (53.41%) patients underwent concomitant surgery: 28 (27.5%) underwent mitral valve replacement, and 13 (12.7%) underwent coronary artery bypass graft surgery. Results: Mean valve index was 0.82±0.08 cm2/m2. Overall, 17 (16.83%) patients had a valve index lower than 0.75 cm2/m2, without statistical significance for mortality (P=0.12). The overall 10-year survival rate was 83.17%. The rate for patients who underwent isolated aortic valve replacement was 91.3% and 73.1% (P=0.02) for patients who underwent concomitant surgery. In the univariate analysis, the main predictors of mortality were preoperative ejection fraction (P=0.02; HR 0.01) and EuroSCORE II results (P=0.00000042; HR 1.13). In the multivariate analysis, the main predictors of mortality were age (P=0.01, HR 1.04) and concomitant surgery (P=0.01, HR 5.04). Those relationships were statistically significant. Conclusion: A valve index of < 0.75 cm2/m2 did not affect 10-year survival. However, concomitant surgery and age significantly affected mortality.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/mortality , Postoperative Complications , Time Factors , Survival Rate , Retrospective Studies , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality
SELECTION OF CITATIONS
SEARCH DETAIL