Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Pesqui. vet. bras ; 36(12): 1203-1208, Dec. 2016. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-842028

ABSTRACT

The purpose of this study is to evaluate healthy conscious guinea pigs as a model for electrophysiology assessment and to describe normal electrocardiographic patterns in controlled laboratory environment, establishing the best QT formula for this method. Electrocardiographic recordings of fifty adult conscious guinea pigs were obtained using a computerized electrocardiography. The electrocardiographic measurements of three different tracings were analyzed. The results obtained established normal mean and range values for the parameters: heart rate, waves and intervals of P-QRS-T deflections, as well as the mean cardiac axis. Groups were separated by body weight: group 1 gathered animals with 500-699g and group 2 with animals 700-900g. No differences were found when measurements were compared between groups, showing no significant difference between weight/body sizes to the electrocardiographic parameters (P<0.05). The mean corrected QT values (QTc) obtained using diverse formulae were significantly different (P<0.05), were the most consistent was Van der Water (QTcV). QTcV values were strongly correlated (r=98) and 95% confidence interval 185.7 to 195.2ms.Considering its simplicity and reliability, the QTcV was deemed the most appropriate to be used for the correction of QT interval in conscious guinea pigs.The results of this study also suggest that the values found can be used as reference for the species.(AU)


O objetivo desse estudo foi avaliar cobaios hígidos e conscientes como modelos para estudos de eletrofisiologia e descrever os padrões eletrocardiográficos normais em ambiente laboratorial controlado, estabelecendo a melhor fórmula QT para esse método. Gravações eletrocardiográficas de cinquenta cobaios adultos conscientes foram obtidas usando eletrocardiografia computadorizada. As medidas eletrocardiográficas de três trechos diferentes foram analisadas. Os resultados estabeleceram média e desvio padrão para os parâmetros: frequência cardíaca, ondas e intervalos P-QRS-T, assim como o eixo cardíaco médio. Grupos foram separados de acordo com o peso: grupo 1 incluiu animais com 500-699g e o grupo 2 animais de 700-900g. Nenhuma diferença foi encontrada quando as medidas foram comparadas entre os grupos, mostrando que não há diferença significativa entre peso/tamanho corporal com os parâmetros eletrocardiográficos (p<0.05). As médias corrigidas dos valores do QT (QTc) obtidas usando diferentes fórmulas foram significativamente diferentes (p<0.05), sendo a mais consistente a de Van der Water (QTcV). Valores de QTcV fortemente correlacionam com o QT (r=98), com intervalo de confiança a 95% de 185.7 a 195.2 ms. Considerando a simplicidade e confiabilidade, o QTcV foi considerado apropriado para correção do intervalo QT em cobaios conscientes. Os resultados do presente estudo também sugerem que os valores encontrados possam ser utilizados como referência para essa espécie.(AU)


Subject(s)
Animals , Guinea Pigs , Electrocardiography/veterinary , Electrophysiological Phenomena , Heart Rate , Reference Standards/analysis , Body Weights and Measures/veterinary
2.
Pesqui. vet. bras ; 34(5): 469-472, May 2014. tab
Article in English | LILACS | ID: lil-714719

ABSTRACT

The electrocardiography (ECG) QT interval is influenced by fluctuations in heart rate (HR) what may lead to misinterpretation of its length. Considering that alterations in QT interval length reflect abnormalities of the ventricular repolarisation which predispose to occurrence of arrhythmias, this variable must be properly evaluated. The aim of this work is to determine which method of correcting the QT interval is the most appropriate for dogs regarding different ranges of normal HR (different breeds). Healthy adult dogs (n=130; German Shepherd, Boxer, Pit Bull Terrier, and Poodle) were submitted to ECG examination and QT intervals were determined in triplicates from the bipolar limb II lead and corrected for the effects of HR through the application of three published formulae involving quadratic, cubic or linear regression. The mean corrected QT values (QTc) obtained using the diverse formulae were significantly different (ρ<0.05), while those derived according to the equation QTcV = QT + 0.087(1- RR) were the most consistent (linear regression). QTcV values were strongly correlated (r=0.83) with the QT interval and showed a coefficient of variation of 8.37 percent and a 95 percent confidence interval of 0.22-0.23 s. Owing to its simplicity and reliability, the QTcV was considered the most appropriate to be used for the correction of QT interval in dogs.


O intervalo QT do eletrocardiograma (ECG) é influenciado por variações da frequência cardíaca (FC), o que pode levar a erros na interpretação de sua duração. Considerando que as alterações na duração do intervalo QT refletem anormalidades da repolarização ventricular, as quais predispõem a ocorrência de arritmias, esta variável deve ser devidamente avaliada. O objetivo deste trabalho foi determinar qual método de correção do intervalo QT é mais adequado para os cães, considerando-se diferentes intervalos de FC normais. Cães adultos saudáveis, de diferentes raças (n=130; Pastor Alemão, Boxer, Pit Bull Terrier e Poodle) foram submetidos ao exame eletrocardiográfico, no qual se determinaram os intervalos QT a partir da derivação bipolar II e foram corrigidos os efeitos da FC por meio da aplicação de três fórmulas, envolvendo regressão quadrática, cúbica ou linear. Os valores do QT corrigido (QTc) obtidos utilizando as diversas fórmulas foram significativamente diferentes (ρ<0,05), sendo os derivados da equação QTcV = QT + 0,087 (1- RR), os mais consistentes (regressão linear). Valores de QTcV apresentaram correlação significativa e de alta magnitude (r=0,83) com o intervalo QT, baixo coeficiente de variação (8,37 por cento) e intervalo de confiança de 95 por cento de 0,22-0,23s. Devido à confiabilidade dos dados, o QTcV foi considerado o mais apropriado para ser utilizado para a correção do intervalo QT em cães, além de ser um método de fácil execução.


Subject(s)
Animals , Male , Female , Dogs , Dogs/physiology , Electrocardiography/veterinary , Heart Rate , Arrhythmias, Cardiac/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL