Article in English | LILACS-Express | LILACS | ID: biblio-1365523

ABSTRACT

ABSTRACT This is a quantitative methodological study for the validation of a research instrument. It aimed to validate the data from the TrackHealth accelerometry device. The sample consisted of 30 adult individuals of both sexes selected by convenience who met the inclusion and exclusion criteria. The physical activity monitors used for the research protocol were the ActiGraph® wGT3X-BT triaxial accelerometer and the TrackHealth accelerometer (TH). The activity protocol consisted of 4 (four) activities (walking at 4.8 and 6.4 km h1 and running at 9.7 and 12 km h1) performed in the laboratory, on an Ibramed treadmill, lasting 5 (five) minutes at each stage. A difference was found between the raw acceleration data of the two devices, however the TrackHealth device showed higher sensitivity at speeds of 4.8 and 6.4 km/h, and a high level of agreement (2.7-2.8%) at the initial speeds of the magnitude vectors. However, there is still a need for improvement in the functioning of the device, so that TrackHealth can be commercialized.


RESUMO Trata-se de um estudo metodológico quantitativo para validação de um instrumento de pesquisa. O objetivo era validar os dados do dispositivo de acelerometria TrackHealth. A amostra foi composta por 30 indivíduos adultos de ambos os sexos selecionados por conveniência que atenderam aos critérios de inclusão e exclusão. Os monitores de atividade física utilizados para o protocolo de pesquisa foram o acelerômetro triaxial ActiGraph® wGT3X-BT e o acelerômetro TrackHealth (TH). O protocolo de atividades consistiu em 4 (quatro) atividades (caminhada a 4,8 e 6,4 km h1 e corrida a 9,7 e 12 km h1) realizadas em laboratório, em esteira Ibramed, com duração de 5 (cinco) minutos em cada etapa. Foi encontrada uma diferença entre os dados brutos de aceleração dos dois dispositivos, no entanto, o dispositivo TrackHealth apresentou maior sensibilidade nas velocidades de 4,8 e 6,4 km / h, e um alto nível de concordância (2,7-2,8%) nas velocidades iniciais da magnitude vetores. Porém, ainda há necessidade de melhorias no funcionamento do aparelho, para que o TrackHealth possa ser comercializado.

2.
REVISA (Online) ; 9(3): 551-562, 2020.
Article in Portuguese | LILACS | ID: biblio-1122997

ABSTRACT

Objetivo: evidenciar os fatores relacionados a assistência no manejo da hemorragia pós-parto que contribuem para que esse agravo esteja entre as maiores causas de mortalidade materna. Método: Para isso foi realizada uma revisão integrativa da literatura, por meio da análise de periódicos publicados de 2010 a 2019 nas bases de dados SciELO, MEDLINE e PUBMED, além de dados do Ministério da Saúde, da OPAS, da OMS, da Fiocruz e do IBGE. Resultados: Foram encontrados um total de 55 publicações, sendo 40 artigos, 1 livro, 5 manuais, 2 protocolos e 7 publicações em sites oficiais. Na análise final dos estudos 13 artigos, 1 livro, 5 manuais, 2 protocolos e 7 publicações em sites oficiais com dados de saúde foram utilizados para a elaboração da pesquisa. Conclusão: torna-se imprescindível refletir quanto às dificuldades na aplicação de um manejo adequado da HPP, além de todas as consequências que essa intercorrência acarreta na vida dessas mulheres e de seus familiares, fatores esse que evidenciam a magnitude de um problema de saúde pública. Portanto, é inevitável que as políticas públicas, os profissionais de saúde, principalmente aqueles que prestam assistência na área da obstetrícia e os pesquisadores, tenham uma maior cautela em relação a HPP.


Objective: to highlight the factors related to assistance in the management of postpartum hemorrhage that contribute to this condition being among the major causes of maternal mortality. Method: For this purpose, an integrative literature review was carried out, through the analysis of journals published from 2010 to 2019, in the SciELO, MEDLINE and PUBMED databases, in addition to data from the Ministry of Health, PAHO, WHO, Fiocruz and IBGE. Results: A total of 55 publications were found, 40 articles, 1 book, 5 manuals, 2 protocols and 7 publications on official websites. In the final analysis of the studies, 13 articles, 1 book, 5 manuals, 2 protocols and 7 publications on official websites with health data were used to prepare the research. Conclusion: it is essential to reflect on the difficulties in applying proper management of PPH, in addition to all the consequences that this complication has on the lives of these women and their families, factors that demonstrate the magnitude of a public health problem. Therefore, it is inevitable that public policies, health professionals, especially those who provide assistance in the area of obstetrics and researchers, are more cautious in relation to PPH.


Objetivo: destacar los factores relacionados con la asistencia en el manejo de la hemorragia posparto que contribuyen a que esta afección se encuentre entre las principales causas de mortalidad materna. Método: para este fin, se realizó una revisión integral de la literatura, a través del análisis de revistas publicadas de 2010 a 2019, en las bases de datos SciELO, MEDLINE y PUBMED, además de datos del Ministerio de Salud, OPS, OMS, Fiocruz y IBGE Resultados: se encontraron un total de 55 publicaciones, 40 artículos, 1 libro, 5 manuales, 2 protocolos y 7 publicaciones en sitios web oficiales. En el análisis final de los estudios, se utilizaron 13 artículos, 1 libro, 5 manuales, 2 protocolos y 7 publicaciones en sitios web oficiales con datos de salud para preparar la investigación. Conclusión: es esencial reflexionar sobre las dificultades para aplicar un manejo adecuado de la HPP, además de todas las consecuencias que esta complicación tiene en la vida de estas mujeres y sus familias, factores que demuestran la magnitud de un problema de salud pública. Por lo tanto, es inevitable que las políticas públicas, los profesionales de la salud, especialmente aquellos que brindan asistencia en el área de obstetricia e investigadores, sean más cautelosos en relación con la HPP.


Subject(s)
Early Diagnosis , Postpartum Hemorrhage
SELECTION OF CITATIONS