Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Dental press j. orthod. (Impr.) ; 17(6): 154-159, Nov.-Dec. 2012. ilus, graf, tab
Article in English | LILACS | ID: lil-669408

ABSTRACT

OBJECTIVE: To evaluate the mechanical properties of three glass ionomers cements (GICs) used for band cementation in Orthodontics. METHODS: Two conventional glass ionomers (Ketac Cem Easy mix/3M-ESPE and Meron/Voco) and one resin modified glass ionomer (Multi-cure Glass ionomer/3M-Unitek) were selected. For the compressive strength and diametral tensile strength tests, 12 specimens were made of each material. For the microhardness test 15 specimens were made of each material and for the shear bond strength tests 45 bovine permanent incisors were used mounted in a self-cure acrylic resin. Then, band segments with a welded bracket were cemented on the buccal surface of the crowns. For the mechanical tests of compressive and diametral tensile strength and shear bond strength a universal testing machine was used with a crosshead speed of 1,0 mm/min and for the Vickers microhardness analysis tests a Microdurometer was used with 200 g of load during 15 seconds. The results were submitted to statistical analysis through ANOVA complemented by Tukey's test at a significance level of 5%. RESULTS: The results shown that the Multi-Cure Glass Ionomer presented higher diametral tensile strength (p < 0.01) and compressive strength greater than conventional GICs (p = 0.08). Moreover, Ketac Cem showed significant less microhardness (p < 0.01). CONCLUSION: The resin-modified glass ionomer cement showed high mechanical properties, compared to the conventional glass ionomer cements, which had few differences between them.


OBJETIVO: avaliar as propriedades mecânicas de três cimentos de ionômero de vidro (CIVs) utilizados para cimentação de anéis ortodônticos. MÉTODOS: foram utilizados dois CIVs convencionais (Ketac Cem Easy mix/3M-ESPE e Meron/Voco) e um CIV modificado por resina (Multi-Cure Glass ionomer/3M-Unitek). Para os testes de resistência à compressão e tração diametral, foram confeccionados 12 corpos de prova de cada material. Para os testes de microdureza, foram confeccionados 15 corpos de prova de cada material; para os testes de resistência de união ao cisalhamento, foram utilizados 45 dentes bovinos incluídos em resina acrílica, sobre os quais foi cimentada uma lâmina de anel ortodôntico com braquete soldado a ela para a realização dos ensaios. Para os testes de compressão, tração diametral e cisalhamento, foi utilizada uma máquina universal de ensaios a uma velocidade de 1mm/min; para os testes de microdureza Vickers, foi utilizado um microdurômetro com 200g de carga durante 15 segundos. Os resultados foram submetidos à análise estatística ANOVA, complementada pelo teste de Tukey ao nível de significância de 5%. RESULTADOS: os resultados demonstraram que o Multi-Cure Glass Ionomer apresentou resistência à tração diametral significativamente maior (p < 0,01) e maior resistência à compressão (p = 0,08) em relação aos CIVs convencionais. Além disso, o Ketac Cem apresentou microdureza significativamente maior que os demais materiais (p < 0,01). CONCLUSÃO: o CIV modificado por resina apresentou propriedades mecânicas superiores às dos CIVs convencionais, que, por sua vez, apresentaram poucas diferenças entre si.

2.
Article in English | IMSEAR | ID: sea-142925

ABSTRACT

Objective: To compare surface treatments with CVDentUS ® ultrasound tips (UT) and KGSorensen ® diamond burs (DB) on etched (e) and non-etched (n/e) dentin. The microtensile bond strength (μTBS) was measured and fractography was assessed by scanning electron microscope (SEM). Materials and Methods: Sixteen molars were divided into four groups of four teeth each according to treatment (DB-n/e; DB-e; UT-n/e; UT-e). The teeth were restored, sectioned into samples for μTBS (n=40) and tested on a EMIC DL-2000 universal machine (0.5 mm/min) and analyzed by SEM for fracture classification. Statistical Analysis: For analysis of the data on μTBS, the two-way ANOVA, using treatment and acid etching as fixed factor, and the Tukey test were used (α=0.05). To failures classification in cohesive in dentin (CD); cohesive in composite resin (CC); cohesive interfacial on base or top of hybrid layer (CBT); cohesive in adhesive (CA); mixed (M); interfacial on smear layer (S) the Fisher's exact test (α=0.05) was performed. Results: The mean values of μTBS (in MPa) in the different groups were as follows: UT-e: 45.31±8.16; DB-e: 34.04±9.29; UT-n/e: 15.17±3.71; and DB-n/e: 9.86±3.80. On analysis of the SEM micrographs, the DB-n/e group showed total obstruction of dentinal tubules; the UT-n/e group showed partial desobstruction of dentinal tubules and irregular surface; the DB-e group showed complete desobstruction of dentinal tubules; and the UT-e group showed complete desobstruction of dentinal tubules and irregular surface. Conclusion: The combination of ultrasound treatment and acid etching provides high values of μTBS. An association exists between CA/CC failures and the UT method, CBT failure and the DB method, CBT/CC failures and etching, S failure and non-etching.

3.
Rev. odonto ciênc ; 26(1): 40-44, 2011. ilus, graf
Article in English | LILACS, BBO | ID: lil-588600

ABSTRACT

PURPOSE: The present study examined the possibility of modifying the structural properties of glass ionomer cement by adding seashells to form a possible 'scaffold' material for cases of bone formation. METHODS: White and black seashells were ground into a fine, homogeneous powder. To analyze their composition, the seashell samples were submitted to EDX and X-Ray diffraction. The ground seashells were mixed with the glass ionomer cement at either 1, 5 or 10 percent concentrations (in weight). Samples without any seashells were used as the control group. Solutions and GIC samples were analyzed for pH measurement. The structural and superficial analysis of samples was performed by using scanning electron microscopy (SEM). RESULTS: There was no difference in pH values among the tested solutions with different seashell concentrations (1, 5 and 10 percent). In the GIC samples with the shells, the pH values were close to 7.0. The EDX and X-Ray diffraction showed calcium carbonate (CaCO3) peaks for the shell samples. The superficial SEM analysis demonstrated that the samples containing seashells had framework formations in their structures. CONCLUSION: Although there is a need for biocompatibility and cellular cytotoxicity testing in vitro, as well as in vivo evaluation, seashells could be used in glass ionomer cement aiming at the development of a 'scaffold' material for bone grafting or osseointegration.


OBJETIVO: Este estudo examinou a possibilidade de modificar as propriedades estruturais do cimento de ionômero de vidro (CIV) pela adição de conchas para formar um material estrutural, com objetivo de uso em casos de formação óssea. METODOLOGIA: Conchas de cor branca e preta foram transformadas em um pó fino e homogêneo e sua composição foi analisada por EDX e difração por RX. O pó de concha foi misturado a CIV nas concentrações de 1, 5 ou 10 por cento (em peso) para a confecção das amostras. Amostras sem pó de concha foram usadas como grupo controle. Foram realizadas medições de pH de soluções do pó de conchas e das amostras de CIV. A análise estrutural e superficial das amostras foi realizada por microscopia eletrônica de varredura (MEV). RESULTADOS: Não houve diferença de pH entre as soluções testadas com diferentes concentrações de pó de concha (1, 5 ou 10 por cento). Nas amostras de CIV com conchas, os valores de pH foram próximos a 7,0. Os métodos de EDX e difração por RX mostraram picos de carbonato de cálcio (CaCO3) para as amostras com conchas. A análise por MEV demonstrou que as amostras com pó de conchas tinham formações estruturais diferentes do controle. CONCLUSÃO: Embora haja necessidade de testes de biocompatibilidade e citotoxicidade celular, assim como avaliação in vivo, as conchas poderiam ser utilizadas como material de modificação estrutural do cimento de ionômero de vidro em casos de material para enxerto ósseo ou osseointegração.


Subject(s)
Glass Ionomer Cements/chemistry , Glass Ionomer Cements/therapeutic use , Biocompatible Materials , Materials Testing
4.
Rev. odonto ciênc ; 26(2): 151-155, 2011. tab
Article in English | LILACS, BBO | ID: lil-611662

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the influence of filler weight content on selected mechanical properties of six microhybrid composite resins. METHODS: Compressive strength, elastic modulus, Vickers microhardness (VHN), and weight filler content were evaluated in the following dental composites: Admira (AD), Charisma (CH), InTen-S (IN), Tetric Ceram (TC), Point 4 (P4), and Z250 (Z2). RESULTS: Mean values for compressive strength (MPa) ranged from P4 76.60 to Z2 222.33. The elastic moduli (GPa) ranged from IN 2.56 to Z2 4.59. Microhardness VHN ranged from P4 50.53 to Z2 87.88. Filler weight content (Wt percent) ranged from IN 72.51 to TC 79.56. Significant differences were found between the composites (ANOVA/Tukey's, P<0.05). CONCLUSION: Z2 had the highest compressive strength; Z2 and TC showed the highest elastic modulus, VHN and filler weight content. Weight filler content had a strong influence on mechanical properties (0.78

OBJETIVO: O objetivo deste estudo foi avaliar a influência do conteudo de carga, em peso, de seis resinas compostas microhíbrida sobre determinadas propriedades mecânicas. METODOLOGIA: A resistência à compressão, módulo de elasticidade, microdureza Vickers (VHN) e conteúdo de carga de peso foram avaliados nas seguintes resinas compostas: Admira (AD), Charisma (CH), InTen-S (IN), Tetric Ceram (TC), Point 4 (P4) e Z250 (Z2). RESULTADOS: Os valores médios de resistência à compressão (MPa) variaram de P4 76,60 a Z2 222,33. Os módulos de elasticidade (GPa) variou de IN 2,56 a Z2 4,59. A microdureza VHN variou de P4 50,53 a Z2 87,88. O conteúdo de carga em peso (Wt por cento) variou de IN 72,51 a TC 79,56. Foram encontradas diferenças significativas entre as resinas compostas (ANOVA/Tukey's, P<0,05). CONCLUSÃO: A resina Z2 teve a maior resistência à compressão; Z2 e TC apresentaram maiores módulo de elasticidade, VHN e conteúdo de carga em peso. O conteúdo de carga em peso teve uma forte influência nas propriedades mecânicas avaliadas (0,78

Subject(s)
Mechanical Phenomena , Compressive Strength , Composite Resins
5.
RGO (Porto Alegre) ; 58(4): 503-510, dez. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-588565

ABSTRACT

OBJETIVO: Avaliar o alívio interno de coroas totais após a utilização de espaçadores para troqueis. MÉTODOS: Foram confeccionadas 20 coroas metálicas, em níquel-cromo, divididas em quatro grupos de cinco coroas de acordo com o número de camadas de espaçador empregadas. Cada coroa foi submetida à medição do espaço interno, formado entre as suas paredes internas e a parede externa do troquel mestre metálico. Para a medição, uma silicona de adição ultraleve foi injetada no interior das coroas. As amostras assim obtidas foram seccionadas ao meio no sentido ocluso-cervical de modo a obter duas metades, as quais foram escaneadas em alta resolução juntamente com um paquímetro. As imagens obtidas foram levadas ao software Image Tool 3.0 para medição do alívio interno obtido em dois pontos equidistantes em cada uma das paredes axiais e na parede oclusal. Os valores médios obtidos em micrômetros (µm) para condição de alívio nas diferentes paredes foram submetidos à análise estatística através da análise de variância, teste de Tukey e teste t de Student. RESULTADOS: À medida que se aumenta o número de camadas de espaçador aumenta também o alívio interno obtido. O Grupo 4 demonstrou uma espessura elevada na parede oclusal, a qual foi equivalente ao Grupo 2 e explicada pelo não escoamento do material para moldagem no interior da coroa. CONCLUSÃO: A aplicação de espaçadores para troqueis antes da ceroplastia permite ao operador obter fundições com alívio interno controlado, como condição para obter espaço suficiente para o agente cimentante.


OBJECTIVE: This research evaluated the internal relief in full crowns after the use of die spacers. METHODS: Twenty nickel-chromium crowns were made and divided into four groups of five crowns each, according to the number of die spacer layers used .The space between the inside walls and outside walls of the metal master die of each crown was measured. The measurement was done by injecting a very light-bodied addition silicone inside the crowns. The resulting samples were cut in half along the occlusal cervical plane and the halves were scanned in high resolution together with a slide caliper. The resulting images were transferred to the Image Tool 3.0 software for measuring the internal relief obtained from two equidistant points on each axial wall and on the occlusal wall. The relief means in micrometers in the different walls were statistically analyzed by analysis of variance, Tukey test and Student's t-test. RESULTS: As the number of spacer layers increases, so does internal relief. The occlusal wall of Group 4 was very thick, equivalent to that of Group 2, which is explained by the impression material not flowing inside the crown. CONCLUSION: The application of die spacers before waxing allows the operator to obtain casts with controlled internal reliefs, making room for the cement.


Subject(s)
Dental Marginal Adaptation , Crowns , In Vitro Techniques , Dental Casting Technique
6.
Dental press j. orthod. (Impr.) ; 15(1): 80-88, jan.-fev. 2010. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-552075

ABSTRACT

OBJETIVO: avaliar a influência de diferentes variáveis metodológicas sobre a resistência de união ao cisalhamento em estudos in vitro. MÉTODOS: foram utilizados 105 incisivos permanentes bovinos, seccionados ao nível do colo dentário. A porção coronária foi inclusa em tubos de PVC, com resina acrílica autopolimerizável, e com face vestibular voltada para cima. Todos os corpos de prova foram preparados para a colagem com profilaxia e condicionamento ácido na região central das coroas, onde foram posicionados braquetes Morelli® de incisivos centrais superiores, com resina Concise® Ortodôntico (3M/Unitek). Foram determinados três grupos de acordo com a variável estudada: (Grupo 1) - meio de armazenamento dos dentes, previamente à inclusão e à colagem, com solução de timol 0,1 por cento (a), água destilada (b) e congelamento (c); (Grupo 2) - velocidade da célula de carga da máquina de ensaio de 0,5 (a), 1,0 (b) e 2,0mm/min (c) e (Grupo 3) - diferentes marcas comerciais de ácidos fosfóricos a 37 por cento, 3M/Unitek (a), AcidGel (b) e Attack Tek (c). Os corpos de prova foram submetidos ao ensaio mecânico de resistência ao cisalhamento através da máquina Emic DL2000®. Os dados foram analisados estatisticamente por meio do Teste t Student para amostras independentes. RESULTADOS: os resultados demonstraram que no Grupo 1 o subgrupo de congelamento apresentou maiores valores em relação aos outros dois subgrupos, porém sem diferença estatisticamente significativa (p > 0,05). No Grupo 2, a força no momento da ruptura foi menor à medida que era aumentada a velocidade da célula de carga, porém sem diferença significativa entre os subgrupos. No Grupo 3, o ácido da 3M/Unitek apresentou a maior média em MPa, no entanto, também sem diferença significativa entre os subgrupos. CONCLUSÕES: conclui-se, portanto, que as variáveis analisadas neste trabalho não apresentaram influência suficiente para determinação de diferenças estatisticamente significativas...


AIM: Evaluate the influence of several methodological variables on the shear bond strength of in vitro studies. METHODS: 105 bovine incisors were sectioned at the cervical level. The coronary portion was included in PVC rings, fulfilled with auto polymerized acrylic resin, with its labial faces turned to the top. All the samples were prepared for bonding, cleaned and acid etched on the central area of the crowns. In this area, central incisors' MorelliÕ brackets were bonded with ConciseÕ (3M/Unitek). Three testing groups were established, according to the studied variable: Group 1 - storage previous to bonding (a-Thymol 0,1 percent; b- distilled water; c- freezing); Group 2 - crosshead speed of the universal testing machine (a- 0,5mm/min; b- 1,0mm/min; c- 2,00mm/min) and Group 3 - commercial brand of 37 percent phosphoric acid (a- 3M/Unitek; b- Acid Gel; c- Attack Tek). The shear bond strength test was performed at the Emic DL2000Õ universal testing machine. Data was analyzed through the Student's t test for independent samples. RESULTS: In Group 1, the freezing group showed the higher values of shear bond strength when compared to the others, although no statistical difference was observed (p>0,05). For Group 2, the higher the crosshead speed, the lower the shear bond strength, with no statistical difference. In Group 3, the 3M/Unitek brand showed the highest average of shear bond strength in MPa, but also no statistical difference was shown. CONCLUSIONS: The variable analyzed in this research had not presented enough influence to determine significant differences between the results.


Subject(s)
Cattle , Braces , Dental Bonding , Dental Materials , Materials Testing , Shear Strength
7.
Acta odontol. latinoam ; 22(2): 139-142, Sept. 2009. ilus, graf, tab
Article in English | LILACS | ID: biblio-973546

ABSTRACT

This study evaluated the fit between implants and premachined and castable UCLA abutments. All plastic specimens were cast using the conventional technique in accordance with the manufacturer's instructions. Five specimens of each experimental group were measured for vertical and horizontal gaps by scanning electronic microscopy (Phillips XL 30 model, Holland). Gold UCLA (vertical gap: 2.15 μm, horizontal gap: 11.30 μm) and castable rotational UCLA (vertical gap: 14.91 μm, horizontal gap: 59.41 μm) groups showed the lowest and highest mean values, respectively (Neodent, Curitiba, Parana, Brazil). In general, the castable UCLA abutments showed poorer marginal fit than the premachined abutments.


Esse estudo avaliou a adaptacao entre implantes pilares UCLA usinados e fundidos. Todos os corpos de prova de plastico foram fundidos usando tecnica de fundicao convencional de acordo com o fabricante. Cinco corpos de prova foram avaliados em relacao a desadaptacao vertical e horizontal utilizando um Microscopio Eletronico de Varredura. Os grupos UCLA Ouro (desadaptacao vertical: 2.15 μm, horizontal : 11.30 μm) e UCLA rotacional fundido (desadaptacao vertical: 14.91 μm, horizontal: 59.41 μm) mostraram as medias mais baixas e mais altas, respectivamente. De uma maneira geral, os pilares UCLA fundidos mostraram adaptacao menor do que os pilares UCLA usinados.

8.
Rev. odonto ciênc ; 24(1): 19-21, jan.-mar. 2009. tab
Article in English | LILACS, BBO | ID: lil-506370

ABSTRACT

Purpose: To evaluate the effect of chisel width on shear bond strength of composite to dental enamel. Methods: Sixty crowns of bovine incisors were embedded in acrylic resin, and their enamel surfaces were flattened and etched with 35% phosphoric acid. Single Bond (3M/ESPE) adhesive system and Z-250 (3M/ESPE) composite were used to build a cylindrical-shaped restoration perpendicular to the conditioned enamel flat surface. Specimens were divided into four groups and subjected to the shear bond strength testing using a chisel-shaped shearing blade with a 0.5, 1.0, 2.0, or 3.0 mm-width blunt edge in a universal testing machine at crosshead speed of 0.5 mm/min. Data on shear bond strength were analyzed by ANOVA and Duncan's test (á=0.05). Results: Shear bond strength means for the experimental groups were: 0.5 mm - 19.66 MPa; 1 mm - 18.78 MPa; 2 mm - 16.77 MPa; 3 mm - 16.06 MPa. Bond strength was significantly different between the groups tested with chisels of 0.5 and 3 mm-width (P=0.045) showing an inverse relationship between shear bond strength and chisel width. Conclusion: The results suggest that shear bond strength varies as a function of chisel width.


Objetivo: Avaliar a influência de diferentes larguras de cinzel sobre a resistência de união ao cisalhamento na interface esmalte dental/resina composta. Metodologia: As coroas de 60 dentes incisivos bovinos foram incluídas em resina acrílica e as superfícies vestibulares de esmalte foram planificadas e condicionadas com ácido fosfórico a 35 %. O sistema adesivo Single Bond (3M/ESPE) e de resina composta Z-250 (3M/ESPE) foram utilizados para fabricar restaurações cilíndricas de resina composta perpendiculares à superfície plana do esmalte condicionado. Para o teste de cisalhamento, os espécimes foram submetidos ao ensaio mecânico com cinzéis de 0,5 mm, 1,0 mm, 2,0 mm ou 3,0 mm de largura da parte ativa romba, em uma máquina de ensaio universal à velocidade de 0,5 mm/min. Os dados obtidos foram analisados por análise de variância e teste de Duncan ao nível de significância de 5 %. Resultados: As médias de resistência de união ao cisalhamento dos grupos testados foram: 0,5 mm - 19,66 MPa; 1,0 mm -18,78 MPa; 2,0 mm - 16,77 MPa; 3,0 mm - 16,06 MPa. Houve diferença estatisticamente significativa entre os grupos de 0,5 e 3,0 mm (P=0,045), com uma relação inversa entre resistência de união ao cisalhamento e largura do cinzel. Conclusão: Os resultados sugerem que a resistência de união ao cisalhamento sofre influência da largura do cinzel utilizado no ensaio.


Subject(s)
Animals , Cattle , Dental Instruments , Composite Resins , Materials Testing , Shear Strength
9.
Rev. odonto ciênc ; 22(58): 317-320, out.-dez. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-487211

ABSTRACT

O objetivo do presente estudo é comparar e avaliar a microdureza Vickers de um compósito restaurador microhíbrido ativado por dois tipos de unidades polimerizadoras e armazenados em água destilada. Trinta espécimes foram feitos com resina Charisma B1, para cada um dos regimes de polimerização: fotopolimerização por luz halógena, fotopolimerização por LED e fotopolimerização mais ciclo adicional em autoclave. Foram feitas duas leituras de microdureza Vickers por corpo de prova em 1 dia, 7 dias e 14 dias de imersões. O ciclo adicional de polimerização mostrou uma tendência de aumentar os valores de microdureza dos compósitos restauradores, não mostrando diferenças estatisticamente significantes entre LED e Luz Halógena (p > 0,05).


The purpose of this study is to evaluate and compare the Vickers microhardness of one microhybrid composite polymerized with different sources and stored in distilled water for up to 14 days. Thirty samples have been prepared with Charisma composite, shade B1, for each polymerization method: halogen light photopolymerization, LED photopolymerization, photopolymerization plus post-cured cycles in autoclave. Two readings of Vichers micro hardness have been done in each sample on 24h, 7days and 14 days of storage. The post curing method tended to improve the microhardness, but it was not statistically different from halogen or LED curing methods (p > 0.05). After 7 days, the hardness values were higher than the first day, but statistically not different to 14 days (p < 0.05). Post-cured samples in autoclave had an improved mean value, however, without differing from those of the LED and halogen.


Subject(s)
Composite Resins , Hardness Tests
10.
ImplantNews ; 4(1): 59-62, jan.-fev. 2007. ilus
Article in Portuguese | LILACS, BBO | ID: lil-461750

ABSTRACT

A utilização de implantes na reabilitação oral de pacientes já é consagrada na Odontologia moderna. Novas indicações são atribuídas aos implantes dentários a cada dia que passa. Antigamente indicado para reabilitação de desdentados totais e hoje já utilizado na resoluçãode casos unitários e parciais. De maneira categórica, os pilares pré-fabricados são uma alternativa viável para resoluções funcional e estética de um número considerável de casos.


Subject(s)
Dental Implantation, Endosseous , Dental Implants, Single-Tooth , Dental Prosthesis, Implant-Supported , Dental Restoration, Permanent , Esthetics, Dental , Prostheses and Implants
12.
RFO UPF ; 11(1): 61-64, 2006. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-457211

ABSTRACT

O objetivo deste estudo foi avaliar a resistência à tração diametral entre gessos tipo IV mineral e sintético. Foram confeccionadas trinta amostras a partir de uma matriz bipartida de teflon cilíndrica de 6mm de diâmetro e 3 mm e altura, com os materiais Vel Mix (kerr), Tuff Rock (Talladium) e Fuji Rock EP (GC Europe). Todos os materiais foram manipulados manualmente de acordo com as especificações dos fabricantes. Após a manipulação dos materiais para modelo, estes foram vazados na matriz sob vibração e armazenados por 24 horas. A seguir, os testes de tração diametral foram realizados numa máquina de ensaio universal (EMIC DL 2000), com velocidade de carregamento de 0,05 mm/min, no sentido de compressão até ocorrer a ruptura. A tensão máxima de fratura foi obtida em Newton (N) e transformada em Magapascal (MPa). Os dados foram submetidos ao teste de análise de variância e Tukey (p<0,05). Os resultados obtidos foram: Fuji Rock EP (8,48 MPz), Tuff Rock (7,91 MPa) e Vel Mix (5,09 MPa). A menor (5,09 MPa). A menor resistência à tração diametral foi verificada no grupo Vel Mix, já os grupos Tuff Rock e Fuji Rock EP apresentaram as maiores médias, no entanto não diferiram estatisticamente


Subject(s)
Calcium Sulfate , Resins , Tensile Strength
13.
Ortodon. gaúch ; 9(2): 142-148, jul.-dez. 2005. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-853018

ABSTRACT

A colagem de bráquetes sobre restaurações de cerâmica tem sido uma necessidade cada vez mais freqüente nas intervenções ortodônticas. Este procedimento pode ser realizado por meio de tratamentos da superfície da cerâmica, como o condicionamento com ácido fluorídrico, o jateamento com óxido de alumínio, a asperização com ponta diamantada e o uso do silano, associados ao emprego de adesivos e resinas compostas, assim como de cimentos de ionômero de vidro modificados por resina. Quando algum tratamento da superfície estiver associado ao silano, pode-se realizar somente a aplicação do silano seguido do adesivo e resina composta, devido à maior possibilidade de fratura da cerâmica durante a descolagem. Para reduzir os riscos de danos à superfície da cerâmica durante a descolagem, a literatura sugere o emprego do silano associado ao cimento de ionômero de vidro modificado por resina para colar bráquetes em superfície cerâmica.


Subject(s)
Acid Etching, Dental , Adhesives , Composite Resins , Dental Bonding , Orthodontic Brackets
14.
Rev. odonto ciênc ; 20(50): 299-307, out.-dez. 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-436387

ABSTRACT

Objetivo: Mensurar a densidade óptica das fibras de reforço Connect, Ribbond e Interlig incluídas em resina composta Filtek 2250, no sistema DenOptix®. Materiais e método: Foram confeccionados 10 blocos de resina composta associadas a cada tipo de fibra e dois blocos de resina Z250 pura (controle não-reforçado), totalizando 32 corpos-de-prova. Foram obtidas 3 radiografias digitais de cada corpo-de-prova, sobre uma placa óptica do sistema DenOptix®, para cada posição: (A) face lateral da fibra exposta aos raios-X; (B) face tramada da fibra exposta aos ralos-X. Em cada uma foram realizadas 3 leituras ópticas dos níveis de cinza em cada corpo-de-prova, em pontos aleatórios, sendo obtida uma média. Os valores médios dos níveis de cinza foram analisados pelo teste t de Student, ANOVA e teste de Tukey, ao nível de significâncla de 1 %. Resultados e conclusões: Com relação à associação da resina + fibra na posição (A), observou-se a maior média de níveis de cinza para a resina pura, seguido por resina + Connect, resina + Interlig (que não diferiram entre si), e resina + Ribbond. Com relação à associação da resina + fibra na posição (B), observou-se que a resina pura apresentou maior média, seguida por resina + Connect, resina + Interlig e resina + Ribbond, sendo que as duas últimas não foram diferentes entre si. Os resultados sugerem que os níveis de cinza variaram em função do tipo de fibra de reforço e da posição na radiografia


Subject(s)
Denture Bases , Radiographic Image Enhancement , Composite Resins
15.
Rev. bras. odontol ; 62(1/2): 92-96, 2005. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-427973

ABSTRACT

O objetivo deste estudo foi determinar quais marcas comerciais de luvas de látex apresentavam algum tipo de reação química impeditiva da polimerização completa das siliconas de adição (pasta densa e leve) pelo contato direto e indireto. Foi avalida a reação, de viscosidade leve e pesada, em contato direto com dez marcas comerciais de luvas de látex nacionais. A maior parte das luvas de látex testadas inibiu a polimerização da silicona de adição. Isso comprova que as siliconas de adição não devem entrar em contato com luvas de látex durante os procedimentos clínicos para evitar que sofram alterações das suas propriedades físico-químicas


Subject(s)
Latex , Gloves, Surgical/standards , Silicones/standards
16.
Rev. odonto ciênc ; 19(46): 389-394, out.-dez. 2004. tab
Article in Portuguese | LILACS, BBO | ID: lil-412489

ABSTRACT

A sensibilidade dentária é um efeito colateral considerado comum e indesejável durante o clareamento dentário, sendo o flúor tópico indicado como um dos meios de evitar esta ocorrência. O presente trabalho, realizado sob a forma de um estudo clínico duplo-cego, teve por objetivo investigar a capaciade dessensibilizante do flúor tópico a 0,05 por cento e 5 por cento durante clareamento caseiro com peróxido de carbamida a 10 por cento. Um total de 33 pessoas (idade entre 18 a 30 anos) foi selecionado, os quais utilizaram durante 1,5 horas, Peróxido de Carbamida a 10 por cento (Opalescence), por 14 dias. Estes foram divididos em três grupos de 11 (placebo, flúor a 0,05 por cento, flúor a 5 por cento) aleatoriamente, recebendo em esquema duplo-cego um dos três tratamentos suplementares para utilização em moldeira individual durante 1 minuto. Terminado o tratamento, os pacientes responderam um questionário sobre sensibilidade. A análise das fichas sobre sensibilidade demonstrou que, para o grupo placebo, houve um índice de 63,63 por cento dos pacientes com sensibilidade e, para os grupos que utilizaram gel de flúor a 0,05 por cento e 5 por cento, respectivamente, 80 por cento e 60 por cento. O cruzamento de variáveis com Teste do Qui-quadrado e Prova Exata de Fisher (p < 5 por cento) quanto ao índice de sensibilidade durante o clareamento, demonstrou não haver dependência entre a variável em questão com relação ao grupo. Este protocolo de uso do flúor tópico não demonstrou ser eficaz na atenuação de sensibilidade dentária durante clareamento caseiro


Subject(s)
Humans , Male , Female , Adolescent , Adult , Tooth Bleaching/adverse effects , Fluorides, Topical , Dentin Sensitivity/chemically induced , Double-Blind Method
17.
Rev. odonto ciênc ; 19(45): 250-257, jul.-set. 2004. tab
Article in Portuguese | LILACS, BBO | ID: lil-412402

ABSTRACT

Este estudo mensurou os níveis de cinza de resinas de alta viscosidade (ALERT, PRODIGY CONDENSABLE, SOLITAIRE e SUREFIL) nas espessuras de 1, 2, 3 e 4 mm utilizando um sistema indireto de digitalização de imagem (DentScan DentView). Foram confeccionadas 20 placas de acrilíco transparente de 5,7 cm x 7,1 cm, que correspondem aproximadamente à área de um filme radiográfico do tipo occlusal, com espessuras de 1, 2, 3 e 4 mm. Cada placa foi dividida em 4 quadrantes e ao centro de cada quadrante foi confeccionado um orifício com 4 mm de diâmetro cada um e, cujas profundidades, foram correspondentes à espessura total de cada placa. Os orifícios serviram de sítio para as resinas a serem pesquisadas, que ali foram inseridas, condensadas e fotopolimerizadas. As vinte placas de acrílico foram fixadas sobre uma placa de vidro liso transparente, com 5 mm de espessura, que estava forrada por uma lâmina plástica para transparência recortada nas mesmas dimensões. A imagem radiográfica digitalizada foi obtida através de um scanner, com três vezes de aumento e o nível de cinza foi avaliado usando uma escala milimétrica. Para cada uma das 60 imagens radiográficas, foram realizadas 3 leituras ópticas, totalizando 180. Os valores dos níveis de cinza, para cada leitura de cada resina composta, foram registrados em planilhas e os dados analisados mediante os testes estatísticos de Kruskal-Wallis e Student-Newman-Keuls ao nível de significância de 5 por cento. Pode-se concluir, que a medida que aumentam as espessuras, correspondentemente aumentam as expressões de níveis de cinza das resinas estudadas. A resina Solitaire apresentou o menor nível mediano de cinza seguida pela Alert. A resina Surefil apresentou o maior valor mediano de nível de cinza entre todas as resinas. A resina Prodigy teve expressão de nível inferior ao da Surefil e maior do que o expresso pela Alert


Subject(s)
Radiographic Image Enhancement , Composite Resins
18.
Rev. odonto ciênc ; 19(44): 192-196, abr.-jun. 2004. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-397038

ABSTRACT

Este estudo in vitro avaliou a resistência de união ao cisalhamento de "brackets"ortodônticos (Morelli) ao esmalte bovino, com ionômero de vidro modificado por resina (Fuji Ortho LC - GC-America), onde as superfícies foram contaminadas por sangue e saliva. Utilizaram-se 45 incisivos permanentes bovinos que foram seccionados, incluídos em tubos plastícos e distribuídos aleatoriamente em três grupos: Grupo I - superfície dentária contaminada por sangue humano; Grupo II - superfície contaminadas com saliva e o Grupo III, sem contaminação. Após a profilaxia, as superfícies foram condicionadas com ácido fosfórico a 37 por cento por 30 segundos e os "brackets" cimentados conforme as especificações do fabricante. Os corpos de prova foram então armazenados por 1 hora a 23°C e 100 por cento de umidade relativa, depois ficaram durante 7 dias imersos em água destilada a 37°C, em seguida, foram submetidos ao teste de resistência ao cisalhamento na máquina de ensaio universal (EMIC, DL 2000), com taxa de deslocamento de 0,5 mm/min. Os dados foram analisados com ANOVA e Método de Tukey. Os resultados mostraram que a contaminação durante o procedimento de colagem diminuiu a resistência da união ao cisalhamento; não houve diferença estatisticamente significante entre os grupos contaminados por sangue ou saliva (grupo I e II) e a resistência de união no grupo sem contaminação (grupo III) foi superior estatisticamente em relação aos demais. O Índice de Adesivo Remanescente (ARI) sugeriu diferença significativa no padrão de descolagem entre os grupos contaminados e o grupo sem contaminação


Subject(s)
Animals , Orthodontic Brackets , Glass Ionomer Cements , Dental Bonding , Environmental Pollution , In Vitro Techniques
19.
Rev. dent. press ortodon. ortopedi. facial ; 8(6): 89-97, nov.-dez. 2003. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-404252

ABSTRACT

Neste estudo "in vitro" avaliou-se a resistência ao cisalhamento da união de braquetes ortodônticos ao esmalte, obtida através de três cimentos de ionômero de vidro fotopolimerizáveis. Utilizaram-se 48 incisivos permanentes bovinos que foram seccionados, incluídos em tubos plásticos e distribuídos aleatoriamente em três grupos: Grupo I, no qual os braquetes foram cimentados com Ortho Glass LC (DFL) do tipo pó/líquido; Grupo II, com braquetes cimentados com Ortho Glass PLC do tipo pasta/pasta; e Grupo III, com braquetes cimentados com Fuji Ortho LC (GC), do tipo pó/líquido. As superfícies dentárias foram condicionadas com ácido fosfórico a 37 por cento por 60 segundos e os braquetes (Morelli) cimentados conforme as especificações dos respectivos fabricantes. Após a cimentação, os corpos de prova foram armazenados por 1 hora em ambiente a 37°C e 100 por cento de umidade relativa, e depois, ficaram por 23 horas imersos em água destilada a 37°C. Em seguida, as amostras foram submetidas ao teste de resistência ao cisalhamento na máquina de ensaio universal (Emic, DL2000), com taxa de deslocamento de 0,5mm/min. Os resultados mostraram que não houve diferença estatisticamente significante (p<0,05) entre os Grupos I e II, entretanto, foi encontrada diferença do Grupo III em relação aos Grupos I e II. Concluiu-se que os três cimentos avaliados apresentaram valores de resistência de união compatíveis com as necessidades clínicas, embora o Fuji Ortho LC tenha apresentado valores inferiores aos demais. Não houve diferença no Índice de Adesivo Remanescente (IAR) entre os três grupos, sugerindo que os produtos avaliados apresentaram o mesmo padrão de descolagem


Subject(s)
Dental Bonding , Glass Ionomer Cements
20.
RGO (Porto Alegre) ; 51(5): 440-442, nov.-dez. 2003. ilus
Article in Portuguese | LILACS, BBO | ID: lil-405562

ABSTRACT

Esta técnica aqui apresentada, demonstra a simplificação de um método para fabricação de uma placa oclusal estabilizadora, utilizando uma base de resina fotopolimerizável (Preci Tray Yeti), produzida pela Yeti Dentalprodulate, Industriosfrasse (Alemanha) e um aparelho fotopolimerizador para laboratório marca EDG. A maior vantagem desta técnica é a previsibilidade de sua pré-polimerização, pois permite resultados definitivos com relação ao trabalho final, já que é possível acrescentar fragmentos de resina ainda não ativados na matriz ou corpo principal da placa parcialmente fotopolimerizável.


Subject(s)
Composite Resins , Occlusal Splints , Methods
SELECTION OF CITATIONS
SEARCH DETAIL