Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Arq. bras. med. vet. zootec. (Online) ; 71(6): 1909-1916, Nov.-Dec. 2019. ilus
Article in English | LILACS, VETINDEX | ID: biblio-1055110

ABSTRACT

The study evaluated sonographic and serologic exams performed for early (20 to 30d) diagnosis of pregnancy. One hundred-twenty (n= 120) bovine recipients were synchronized (estrous=D0) and timed embryo transferred (TET, D7) with fresh in vitro produced embryos. In the first trial (n= 46), diagnosis of pregnancy was performed on day 20 (D20) by detecting CL blood flow (BF) and by Pregnancy-Associated Glycoproteins (PAGs) serology. In the second trial (n= 30), pregnancy diagnosis was performed on D25 by ultrasound visualization of uterine contents and by PAGs serology. In the last trial, PAG's serology was performed on D30. Ultrasonographic detection of the uterine contents and embryo viability performed on D30 (DG30) was considered the gold standard. The PROC FREQ procedure was used to test the agreement between diagnostic methods. On D20, the Doppler ultrasonography of the CL had showed high sensitivity (100%), but only moderate specificity (53.3%). On the same day, serologic diagnostic had no agreement (k= -0.08, P< 0.46) with the gold standard, with very low sensitivity (6.3%). However, the sensitivity of the serologic exam increased dramatically (from 6.3 to 100%) from D20 to D25, and it contributed to detect false negatives from the ultrasound diagnosis, improving the overall accuracy from 90% to 96.7%.(AU)


O estudo foi planejado para correlacionar exames ultrassonográficos e sorológicos realizados para o diagnóstico precoce (20 a 30d) de gestação. Cento e vinte (n= 120) receptoras bovinas foram sincronizadas (estro=D0), e embriões frescos produzidos in vitro foram transferidos em tempo fixo (TETF, D7). No experimento 1 (n= 46), o diagnóstico de gestação foi realizado no D20, pela detecção do fluxo sanguíneo do CL e pela sorologia de glicoproteínas associadas à gestação (PAGs). No experimento 2 (n= 30), a detecção da gestação foi realizada por meio da visualização do conteúdo do útero e também pela sorologia para PAGs. No experimento 3, a sorologia para PAGs foi realizada no D30. Em todos os experimentos, a visualização ultrassonográfica da vesícula e da viabilidade embrionária, realizada no D30, foi considerada padrão-ouro. O procedimento PROC FREQ testou o nível de concordância dos métodos diagnósticos. No D20, o diagnóstico baseado na vascularização do CL mostrou alta sensibilidade (100%) e apenas moderada especificidade (53,3%). Nesse mesmo dia, o diagnóstico sorológico não apresentou concordância (k=-0,08, P<0,46) com o padrão-ouro, além de baixa sensibilidade (6,3%). No entanto, a sensibilidade do exame sorológico aumentou drasticamente (6,3 para 100%) do D20 para o D25, contribuindo para detectar falsos negativos diagnosticados pela ultrassonografia, melhorando a acurácia (90 para 96,7%).(AU)


Subject(s)
Animals , Female , Pregnancy , Cattle , Pregnancy, Animal/blood , Serologic Tests/veterinary , Glycoproteins/analysis , Ultrasonography, Doppler, Color/veterinary , Embryo Transfer/veterinary
2.
Arq. bras. med. vet. zootec ; 67(2): 405-410, Mar-Apr/2015. tab, graf
Article in Portuguese | LILACS, VETINDEX | ID: lil-747033

ABSTRACT

O dispositivo de liberação de progesterona (DLP) é muito importante em protocolos de Inseminação Artificial em Tempo Fixo (IATF). Representa cerca de 43% dos custos e é objeto de estudos sobre a eficiência da sua reutilização. No entanto, perfis de liberação de progesterona (P4) em animais com diferentes concentrações endógenas desse esteroide não são claramente descritos. Este estudo teve como objetivo avaliar a concentração sérica de P4 em fêmeas com diferentes situações de atividade luteal, tratadas com DLP novo (1g de P4) por 8 dias. Trinta novilhas mestiças cíclicas foram divididas em três grupos: em G1 e G2, o DLP foi inserido (D0) sete dias após a ovulação induzida. Adicionalmente, 0,15mg de D-cloprostenol foi administrado três dias depois para promover a luteólise em G2. Para G3, o corpo lúteo foi lisado antes da inserção do DLP para que a P4 exógena fosse a única fonte desse hormônio. O sangue foi coletado no D0, D3, D5 e D8, e a P4 avaliada por RIA. Médias de P4 foram comparadas entre os grupos em cada dia e dentro do grupo, entre os dias, utilizando o teste Tukey. Antes da inserção do implante (D0), os níveis de P4 foram, nos grupos, semelhantes em G1 e G2, e superiores a G3 (5,3±3,1a e 5,3±1,4avs 0,6±0.3bng/mL, respectivamente-P<0,05). No D3, ocorreu o mesmo perfil (5,7±2,6a e 5,4±2,0a e 3,6±0.8bng/mL, respectivamente para G1 e G2 vs G3, P<0,05). Trinta e seis horas (D5) após a PGF, a P4 no G2 caiu para níveis semelhantes aos do grupo G3 e ambos diferiram (P<0,05) de G1 (3,3±1,6b vs 2,4±0,9b e 2,1±0.7bng/mL). Essa diferença se manteve (P<0,05) em D8 (3,1±1,3a, 1,8±0,8b e 1,6±0.6b ng/mL). O aumento da P4 após a inserção (D3 - D0) foi maior (P<0,05) em G3 que em G1 e G2 (2,8±0,9a vs 0,4±1,8b e 0,2±1.4bng/mL). Os animais com maior P4 endógena levam a menor liberação de P4 exógena a partir do DLP. Portanto, os níveis remanescentes de P4 no DLP após o uso dependem da concentração endógena de P4 do animal e possíveis alterações durante a permanência.(AU)


The progesterone (P4) device is a very important step in the ovulation control in Timed Artificial Insemination (TAI) protocols. It represents about 43% of the hormone costs, thus it has been the subject of several studies on efficiency of the reused device as an alternative to reduce TAI costs. However, to our knowledge, profiles for P4 release in animals with different endogenous concentrations of P4 are not clearly described. This study aimed to evaluate serum concentration of P4 in females with different ovarian conditions - related to luteal activity - and treated with a new intravaginal device (1g of P4) for 8 days. Thirty normally cyclic crossbred heifers were divided into three groups: for G1 and G2, P4 device was inserted (D0) seven days after ovulation (7 day old CL). Additional PGF (0.15 mg of D-cloprostenol) was given three days later to promote luteolysis in the G2 group. For G3, CL was killed before P4 insertion and the exogenous progesterone was the only source of this hormone. Blood samples were collected on D0, D3, D5 and D8 and P4 concentration was measured by radioimmunoassay (RIA). Means for P4 concentration were compared among groups in each day and within the group among days using the Tukey test. Before P4 device insertion (D0), P4 levels were higher (P<0.05) in G1 and G2 when compared to G3 (5.3±3.1 and 5.3±1.4 vs. 0.6±0.3ng/mL, respectively). Three days later (D3), the same pattern was observed (5.7±2.6 and 5.4±2.0 and 3.6±0.8ng/mL, respectively for G1 and G2 vs. G3, P<0.05). Thirty-six hours (D5) after PGF injection (G2), P4 in G2 dropped to levels similar to the G3 group and both differed (P<0.05) from G1 (3.3±1.6 vs. 2.4±0.9 and 2.1±0.7ng/mL, G1 vs. G2 and G3, respectively). There were no differences (P>0.05) among groups on D8 (3.1±1.3, 1.8±0.8 and 1.6±0.6ng/mL, respectively, for G1, G2 and G3). Progesterone increase after P4 insertion (D3 - D0) was higher (P<0.05) in G3 compared to G1 and G2 (2.8±0.9 vs. 0.4±1.8 and 0.2±1.4ng/mL, respectively). The interpretation was that animals with higher endogenous P4 promote less release of the exogenous P4 from the device. Therefore, the remaining P4 levels from used progesterone devices depend on the physiological condition of the animal at the time of insertion and possible changes during the treatment.(AU)


Subject(s)
Animals , Female , Cattle , Progesterone/administration & dosage , Insemination, Artificial/veterinary , Corpus Luteum , Ovarian Follicle , Suppositories/administration & dosage
3.
Arq. bras. med. vet. zootec ; 66(1): 305-309, fev. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-704038

ABSTRACT

The aim of this study was to compare the reproductive efficiency in dairy cows with retained placenta (RP), treated with Florfenicol associated or not with Cloprostenol. One hundred and eight cows with RP from dairy herds in southern Minas Gerais state and northern São Paulo state, were included for this purpose. The experiment was designed in factorial 2X2 . The four treatments encompassed two levels of each factor : 1 ) Florfenicol - 4 0mg/kg ( IM) divided in two injections or 40mg / kg ( SC) in one injection after calving; 2) Cloprostenol (0.530mg) - two injections associated with florfenicol treatment or without cloprostenol. The analysis of discrete variables used the Kruskal - Wallis (fou r groups) or Wilcoxon (two groups) statistic to compare groups. The Student "T" test was used to compare means of continuous variables. The overall occurrence of RP was 20.7%. The florfenicol groups had no effects on postpartum uterine health or subsequent reproductive efficiency of the cows. The cloprostenol injections of RP hastened the uterine involution and decreased the occurrence of uterine infection, and increased the percentage of animals with corpus luteum between 25 and 40 days after parturition. The intervals from parturition to first artificial insemination (AI) and to conception, as well as the number of AI per conception were reduced in the cloprostenol treatment.


Subject(s)
Animals , Placenta/anatomy & histology , Uterus/anatomy & histology , Cattle/classification
SELECTION OF CITATIONS
SEARCH DETAIL