Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. pharm. sci ; 49(1): 175-184, Jan.-Mar. 2013. ilus, graf, tab
Article in English | LILACS | ID: lil-671413

ABSTRACT

A stability-indicating high-performance liquid chromatographic (HPLC) method was developed with short run time and validated for the assay of process related impurities of pantoprazole in bulk form. Resolution of drug, its potential impurities and degradation products were achieved on a Hypersil ODS column utilizing a gradient with 0.01 M phosphate buffer of pH 7 and acetonitrile as eluent, at the detection wavelength of 290 nm. Flow rate was set at 1 mL min-1. The procedure was found to be specific, linear (r=0.999), recovery (97.9-103%), LOD (0.043-0.047 µgmL-1), LOQ (0.13-0.14 µgmL-1) and robust. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations. Pantoprazole was found to degrade in acidic, oxidative and under photolytic stress conditions. The drug was stable to alkaline and dry heat conditions. This method has been successively applied to pharmaceutical formulation and no interference from the excipients was found.


Desenvolveu-se método indicador de estabilidade por Cromatografia a Líquido de Alta Eficiência (CLAE) com pequeno tempo de corrida e validado para o ensaio de impurezas relacionadas ao processo de produção de pantoprazol em batelada. A determinação do fármaco, de suas impurezas potenciais e dos produtos de degradação foi realizada com coluna de ODS Hypersil, utilizando gradiente com tampão de fosfato 0,01 M pH 7 e acetonitrila como eluente, no comprimento de onda de detecção de 290 nm. A velocidade de fluxo foi fixada em 1 mLmin-1. O procedimento se mostrou específico, linear (r=0,999), com recuperação (97,9-103%), LOD (0,043-0,047 µgmL-1), LOQ (0,13-0,14 µg mL-1) e robusto. Robustez aceitável indica que o método de ensaio não é afetado por variações pequenas, exceto as planejadas. O pantoprazole degradou em condições ácidas, oxidativas e sob condições de estresse fotolítico. O fármaco foi estável em condições alcalinas e de calor seco. Este método tem sido sucessivamente aplicado à formulação farmacêutica e não se encontrou interferência de excipientes.


Subject(s)
/analysis , Chromatography, Liquid/methods , /methods , Drug Stability
2.
Braz. j. pharm. sci ; 47(2): 379-384, Apr.-June 2011. ilus, tab
Article in English | LILACS | ID: lil-595826

ABSTRACT

Residual solvents in pharmaceutical samples are monitored using gas chromatography with head space. Based on good manufacturing practices, measuring residual solvents is mandatory for the release testing of all active pharmaceutical ingredients (API). The analysis of residual organic solvents (methanol, acetone, cyclohexane, dichloromethane, toluene) in Omeprazole, an active pharmaceutical ingredient was investigated. Omeprazole is a potent reversible inhibitor of the gastric proton pump H+/K+-ATPase. The Head space gas chromatography (HSGC) method described in this investigation utilized a SPB TM-624, Supelco, 30 m long x 0.25 mm internal diameter, 1.4µm-thick column. Since Omeprazole is a thermally labile compound, the selection of the proper injector temperature is critical to the success of the analysis. The injector temperature was set at 170ºC to prevent degradation. The initial oven temperature was set at 40ºC for 12 min and programmed at a rate of 10ºC min-1 to a final temperature of 220ºC for 5 min. Nitrogen was used as a carrier gas. The sample solvent selected was N,N-dimethylacetamide. The method was validated to be specific, linear, precise, sensitive, rugged and showed excellent recovery.


Solventes residuais em amostras farmacêuticas são monitoradas utilizando-se cromatografia a gás "headspace". Com base nas boas práticas de fabricação, a medida de solventes residuais é obrigatória para o teste de liberação de todos os ingredientes farmacêuticos (API). Efetuou-se a análise de solventes orgânicos residuais (metanol, acetona, cicloexano, diclorometano, tolueno) em omeprazol, ingrediente farmacêutico ativo. O omeprazol é potente inibidor reversível da bomba de prótons H+/K+-ATPase. A cromatografia a gás "headspace" (HSGC) descrita nessa pesquisa utilizou um SPB TM-624, Supelco, de 30 m de comprimento x 0,25 mm de diâmetro interno, e coluna de 1,4 µm de espessura. Considerando-se que o omeprazol é termicamente lábil, a seleção da temperatura apropriada do injetor é crítica para impedir a degradação. A temperatura inicial do forno foi de 40 ºC, por 12 minutos, e programada à taxa de acréscimo de 10 ºC min-1 até a temperatura final de 220 ºC, por 5 minutos. Nitrogênio foi utilizado como gás de transporte. Selecionou-se como solvente a N,N-dimetilacetamida. O método foi validado mostrando-se específico, linear, preciso, sensível, robusto e com excelente recuperação.


Subject(s)
Chromatography, Gas , Omeprazole/analysis , Omeprazole/chemistry , Solvents/chemistry , Enzyme Inhibitors/analysis , Enzyme Inhibitors/chemistry , Methodology as a Subject
SELECTION OF CITATIONS
SEARCH DETAIL