Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 29(2): 128-133, mar.-abr. 2016. tab
Article in English, Portuguese | LILACS | ID: biblio-831103

ABSTRACT

Fundamentos: A valvoplastia mitral por cateter-balão foi introduzida em 1984 por Inoue e colaboradores, e atualmente é considerada o método de eleição no tratamento da estenose mitral. Objetivo: Comparar resultados de valvoplastia mitral em pacientes com estenose mitral com comprometimento subvalvar ≥3 e <3. Métodos: Estudo retrospectivo com 104 pacientes submetidos à valvoplastia mitral com balão de Inoue. Os pacientes foram estratificados em dois grupos: com comprometimento subvalvar (ASV) ≥3 e ASV <3. Realizada a comparação dos resultados imediatos, aos 12 meses e aos 24 ou mais meses entre os grupos com os dados obtidos por estudo ecocardiográfico e hemodinâmico. Resultados: Os resultados imediatos mostraram sucesso nos dois grupos, com significância estatística pré/pós procedimento, quanto aos parâmetros ecocardiográficos e hemodinâmicos, e ausência de diferenças significativas entre os grupos. Os resultados ecocardiográficos aos 12 meses evidenciaram que o gradiente médio e a área valvar foram semelhantes e sem significância estatística entre os grupos, o mesmo a correndo na comparação dos resultados ecocardiográficos aos 24 ou mais meses. Conclusão: Os resultados obtidos com a valvoplastia mitral com o balão de Inoue não diferiram tanto nos pacientes com comprometimento do aparelho subvalvar ≥3 quanto <3.


Background: Balloon mitral valvuloplasty was introduced in 1984 by Inoue et al and is currently considered the method of choice in the treatment of mitral stenosis. Objective: To compare results of mitral valvuloplasty in patients with mitral stenosis with subvalvular impairment ≥3 and <3. Methods: Retrospective study with 104 patients undergoing mitral valvuloplasty with Inoue balloon. Patients were stratified into two groups: subvalvular impairment (SVI) ≥3 and SVI <3. The immediate results were compared at 12 months and 24 months or more between the groups with data obtained by echocardiography and hemodynamic study. Results: The immediate results revealed success in both groups, with statistical significance pre/post-procedure regarding the echocardiographic and hemodynamic parameters and no significant differences between groups. Echocardiographic results at 12 months showed that the mean gradient and the valve area were similar and not statistically significant between the groups, the same occurring in the comparison of echocardiographic results at 24 or more months. Conclusion: The results obtained with mitral valvuloplasty with Inoue balloon did not differ both in patients with subvalvular impairment ≥3 and <3.


Subject(s)
Humans , Male , Female , Adult , Mitral Valve Stenosis , Mitral Valve/surgery , Balloon Valvuloplasty/methods , Retrospective Studies , Sex Factors , Data Interpretation, Statistical , Treatment Outcome
2.
Rev. bras. ecocardiogr. imagem cardiovasc ; 26(3): 196-205, jul.-set. 2013. ilus, graf
Article in Portuguese | LILACS | ID: lil-683650

ABSTRACT

Introdução: A nova tecnologia do strain bidimensional (st2d) permite uma análise mais precisa da função global e segmentar do ventrículo esquerdo (VE), incluindo sua porção apical, por ser ângulo-independente. Objetivo: Avaliar a função sistólica global do VE com o st-2d em pacientes (pcs) com Cardiomiopatia Hipertrófica (CMH). Métodos: Foram incluídos 21 pcs com CMH e fração de ejeção do VE preservada (G-CMH), e 21 pcs sem CMH, compondo o grupo controle (G-nl). Foi mensurado o st-2d longitudinal endocárdico global (st2D-L), pela técnica optical flow, dos 18 segmentos do VE, a partir de 3 cortes apicais. Empregou-se o teste t de Student para análise de variáveis contínuas, e o Qui-quadrado (Pearson) para variáveis não contínuas, considerando-se um nível de significância de 0,05. Resultados: Não foi observada diferença entre os grupos quanto à idade, sexo e pressão arterial sistólica e diastólica e frequência cardíaca. Dezesseis pcs do G-CMH apresentavam a forma assimétrica septal da hipertrofia, com envolvimento adicional ou não de paredes adjacentes (G-CMHs), e cinco apresentavam a forma apical da CMH (G-CMHap). Apesar da fração de ejeção do VE ser preservada nos 2 grupos, o st2D-L mostrou-se globalmente reduzido no G-CMH (14,6 + 4,3 vs 18,6 + 2,6% no G-C;p=0,009). No G-CMHs, notou-se valor significativamente menor do st2D-L em relação ao G-nl (13,6 + 3,9 versus 18,5 + 2,5%; p< 0,0002), não havendo diferença significativa entre o G-nl e o G-CMHap. Conclusão: O st2D-L mostrou-se significativamente reduzido na CMH em relação ao G-nl, indicando alteração precoce da função sistólica do VE na CMH, apesar de uma fração de ejeção preservada.


Introduction: The recent developed technology of two-dimensional strain (st2D) allows a more precise analysis of global and segmental function of the left ventricle (LV), including the apical region, due to its angle-independence. Objective: The aim of the study was to evaluate global LV systolic function with st2D in patients (pts) with Hypertrophic Cardiomyopathy (HCM). Methods: We included 21 pts with HCM and preserved LV ejection fraction (G-HCM), and 21 control pcs (G-nl). The global endocardial longitudinal st2D (st2D-L) of 18 myocardial LV segments was measured, by using “optical flow” technology, from the 3 apical views. The Student “t” test was used for analysis of the continuous variables, and the “Chi-square” (Pearson) for the non-continuous variables, considering a significance level of 0,05. Results: No significant difference was observed between the groups regarding age, sex, systolic and diastolic blood pressure, and heart rate. Sixteen pts from the G-HCM presented septal asymmetric hypertrophy, with additional involvement of adjacent walls or not (G-HCMs), and five showed the apical form of HCM (G-HCMap). Although LV ejection fraction was preserved in both groups, the st2D-L was significantly reduced in the G-HCM (14,.1 + 4,3 vs 18,6 + 2,6% in G-nl, p = 0.009). In the G-HCMs the st2D-L was lower compared to G-nl (13,6 + 3.9 vs 18,5 + 2.5%, p <0.0002), with no significant difference between G-nl and G-HCMap. Conclusion: The st2D-L was significantly reduced in pcs with HCM compared to G-nl, indicating early change of LV systolic function in HCM despite a preserved ejection fraction.


Subject(s)
Humans , Analysis of Variance , Cardiomyopathy, Hypertrophic/physiopathology , Ventricular Function, Left , Data Interpretation, Statistical , Stroke Volume/physiology
3.
Rev. bras. ecocardiogr. imagem cardiovasc ; 25(3): 198-205, jul.-set. 2012. tab, ilus, graf
Article in Portuguese | LILACS | ID: lil-641354

ABSTRACT

Introdução: Vários parâmetros ecocardiográficos são propostos na literatura para detecção da dessincronia intraventricular (DV), sem resultados concretos na identificação dos responsivos à terapia de ressincronização cardíaca (TRC). Muitos destes baseiam-se nas curvas de velocidade, ao Doppler tecidual, analisadas somente dentro do período de ejeção sistólico. Com a tecnologia do speckle tracking permitindo calcular a deformidade miocárdica pela imagem bidimensional (st-2d) de maneira ângulo-independente, a sincronia contrátil pode ser avaliada incluindo-se também o período pós-ejeção. Objetivo: Avaliar a DV pelo st-2d em um grupo de pacientes (pcs) com disfunção global e/ou segmentar do ventrículo esquerdo (VE) (G-2), em relação a um grupo de indivíduos com VE normal (G-1), quantificando-se a magnitude da distorção temporal da deformidade miocárdica dos segmentos no período pós-ejeção. Método: Trata-se de um estudo prospectivo de caso e controle, no qual foram incluídos 29 pcs (54,0 ± 17,4 anos; 18 homens), dentre os quais 17 compunham o G-1 e 12, o G-2. Obteve-se a somatória do intervalo de tempo entre o ponto de fechamento valvar aórtico e o pico do st-2d longitudinal de 18 segmentos miocárdicos, a partir dos 3 cortes apicais do VE, derivando o parâmetro Tfao-st. Resultados: Os grupos foram pareados quanto à idade, sexo, frequência cardíaca e pressão arterial, diferindo quanto aos parâmetros ecocardiográficos pelo próprio critério de inclusão. O Tfao-st no G-1 e G-2 foi de 631,4 ± 238,1ms e 1548,0 ± 570,9ms, respectivamente (p< 0,0001). Pela curva ROC, o valor de 900ms foi o que melhor diferenciou os 2 grupos (ASC = 0,93; Sensibilidade: 91%; Especificidade: 88%; p< 0,0001). Conclusão: Em pcs com disfunção segmentar ou global do VE, observou-se um valor médio elevado do Tfao-st em relação ao G-1, indicando maior presença de dessincronia.


Subject(s)
Humans , Male , Female , Middle Aged , Heart Failure/complications , Heart Failure/diagnosis , Prospective Studies , Echocardiography
5.
Rev. bras. ecocardiogr. imagem cardiovasc ; 23(3): 40-45, jul.-set. 2010. tab, ilus, graf
Article in Portuguese | LILACS | ID: lil-556779

ABSTRACT

Fundamentos: Aproximadamente, 30 a 40 por cento dos pacientes (pts) com insuficiência cardíaca respondem, desfavoravelmente, à terapia de ressincronização cardíaca e a Doppler-ecocardiografia tem sido sugerida no refinamento dessa seleção, pelo seu potencial na detecção de dissincronia ventricular (DV) pelos critérios do Doppler tecidual colorido, também em indivíduos com função sistólica preservada (FSP) do ventrículo esquerdo (VE). O objetivo deste estudo foi avaliar a DV, ao DTC, em pts com FSP do VE e o impacto da largura do QRS. Métodos: Foram incluídos 26 pts (48,7 + 16,8 anos; 18 homens), entre os quais, 20 tinham QRS < 120ms (G-I0 e 6 tinham QRS> 120ms (G-II). Ao DTC, mensurou-se: 1) O tempo entre os picos de velocidade (PV) das porções basais septal e lateral (t-SL) do VE; 2) o maior tempo entre os VP dos 6 segmentos basais do VE (t-MAX6); 3) o desvio padrão dos intervalos de tempo entre a onda Q do ECG e o PV dos seis segmentos basais do VE (DP-6). Resultados: Não houve diferença significativa entre os grupos quanto à idade, sexo, fração de ejeção, frequência cardíaca e pressão arterial. Aplicando-se valores acima de 65ms, 36,5ms e 95ms para os parâmetros t-SL, DP-6 d t-MAX6, respectivamente...


Subject(s)
Humans , Male , Female , Middle Aged , Echocardiography, Doppler/adverse effects , Echocardiography, Doppler , Heart Failure/complications , Heart Failure/diagnosis , Stroke Volume , Ventricular Function, Left
6.
Rev. bras. ecocardiogr. imagem cardiovasc ; 22(3): 60-64, jul.-set. 2009. ilus
Article in Portuguese | LILACS | ID: lil-522527

ABSTRACT

O hematoma atrial esquerdo é uma complicação infrequente decorrente de dirversas causas, incluíndo a pós-traumática, devido à intervenção percutânea das artérias coronárias. A ecocardiografia desempenha papel crucial no seu diagnóstico, fornecendo informações quanto à localização, compromentimento hemodinâmico, complicações adicionais e na decisão e acompanhamento terapêutico do paciente. As condições hemodinâmicas estáveis do paciente e o monitoramento ecocardiográfico seriado, mostrando a regressão espontânea do processo, asseguraram a eficácia do tratamento clínico expectante.


Subject(s)
Humans , Male , Middle Aged , Echocardiography/methods , Echocardiography , Heart Atria , Hematoma , Stents
7.
Rev. bras. hematol. hemoter ; 31(supl.1): 93-98, maio 2009. ilus
Article in Portuguese | LILACS | ID: lil-519668

ABSTRACT

Nos últimos anos, a terapia de ressincronização cardíaca tem sido uma conduta bem definida para pacientes com insuficiência cardíaca (IC), classe funcional III ou IV, que não tiveram resposta à otimização terapêutica. Estudos já mostraram esta eficácia, mas um grupo bem definido de miocardiopatias dilatadas com áreas de fibrose não tem tido o mesmo sucesso (30 por cento-40 por cento). Por isto decidimos associar a estes pacientes o implante de células-tronco. A partir de 04/2005 iniciamos estes implantes em pacientes (pcs.) com IC, classe funcional III/IV, otmizados e fração de ejeção <35 por cento com dissincronia ventricular. Total de 25 pacientes (16 homens), idade entre 30-80anos (média de 58) e 44 por cento de etiologia chagásica (11 pcs). Ressincronização e terapia celular foram por via epicárdica (12 pcs) e endocárdica (13 pcs) e a seleção celular pela filtração por Ficoll e 3.0x10(8) de células infundidas CD34 + (5,0 x 10(6)) e CD 133 + (2,5 x 10(6)). Após 24 meses de evolução observamos que 84,8 por cento destes pcs permaneceram vivos e a mortalidade (15,2 por cento) não estava relacionada ao procedimento. A sobrevida dos portadores de marcapasso foi maior (52,4 por cento) e os chagásicos tiveram uma pior sobrevida, mas com teste de long-rank de 0,218 e 0,626, respectivamente. Nos casos de pcs com ressincronizador isoladamente, os resultados não parecem ser tão bons,e nós optamos pela associação de células-tronco como uma alternativa segura e adequada para estes graves pcs com insuficiência cardíaca e miocardiopatia dilatada.


In recent years cardiac resynchronization therapy has been a well defined approach for patients with functional class III or IV heart failure (HF) who do not respond to optimized therapy. Studies have shown efficacy, but one well defined group of dilated heart diseases with large areas of fibrosis has not had the same success rates (30-40 percent). Hence, we decided to associate stem cell transplant in these patients. Since April 2005 we started to transplant stem cells in 25 patients (16 men) with NYHA III/IV HF with ejection fraction < 35 percent and ventricle dyssynchrony. Their ages varied between 30 and 80, (mean age 58) and 44 percent (11 patients) had a chagasic etiology. Resynchronization and stem cell therapy were performed via epicardial (12) or endocardial (13) approaches. Cell selection was by Ficoll filtration with a mean number of 3.0 x 108 cells infused: CD 34+ (5.0 x 106) and CD 133+ (2.5 x 106). In 24 months of evolution we noticed that 84.8 percent of these patients survived and mortality (15.2 percent) was not related to the procedure. The survival of pacemaker recipients (52.4 percent) was higher than another similar group that did not receive pacemaker implants and chagasic patients survived less than the ischemic and the idiopathic patients (42.4 percent, 55.6 percent and 77.2 percent, respectively). In spite of these initial differences, there was no statistical difference between these groups (log-rank test of P=0.218 and P= 0.626, respectively). In cases that resynchronization was performed in isolation, the results do not seem to be satisfactory so we chose to associate stem cell therapy as a safe and adequate alternative for patients with HF and dilated myocardiopathy.


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Cell- and Tissue-Based Therapy , Heart Failure , Heart Failure/therapy , Stem Cells
9.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 19(1): 34-44, jan.-mar. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-438632

ABSTRACT

O advento da ressincronização cardíaca (RC) representou um enorme avanço no campo da terapêutica da insuficiência cardíaca. No entanto, aproximadamente 30 por cento dos pacientes não respondem à RC, o que pode estar relacionado aos critérios de seleção. A ecocardiografia-doppler convencional vem auxiliando na seleção dos possíveis candidatos à RC, no ajuste da programação para cada paciente e na avaliação dos resultados agudos e a longo prazo.


Subject(s)
Humans , Male , Female , Echocardiography/methods , Echocardiography , Heart Failure/complications , Heart Failure/diagnosis , Cardiomyopathy, Dilated/complications , Cardiomyopathy, Dilated/diagnosis , Cardiomyopathy, Dilated/mortality , Quality of Life/psychology
10.
Arq. bras. cardiol ; 82(4): 346-359, abr. 2004. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-358595

ABSTRACT

OBJETIVO: Descrever os achados clínicos e ecocardiográficos de trombose em prótese biológica mitral e o valor do ecocardiograma transesofágico (ETE) no diagnóstico e monitoração da lise do trombo. MÉTODOS: Foram estudados ao ETE 111 pacientes com prótese biológica mitral, e incluídos 4 de 7 com suspeita de trombo nestas próteses (idade média = 60,2±10,2 anos; 2 homens). O diagnóstico pôde ser confirmado pela realização seriada do ETE e pela evolução clínica. Investigaram-se os aspectos morfológicos dos folhetos da prótese, e presença e característica das massas ecogênicas anexas. Foram obtidos o gradiente médio pela prótese e a área valvar. RESULTADOS: O diagnóstico de trombo em prótese biológica mitral foi realizado 48,7±55,2 meses após a cirurgia. Dois pacientes apresentaram acidente vascular encefálico isquêmico no pós-operatório imediato. O gradiente médio global estava elevado (11,4±3 mmHg) e a área valvar reduzida (1,24±0,3cm²). Ao ETE, em todos foram evidenciadas massas ecogênicas em face ventricular esquerda da prótese biológica mitral, sugestivas de trombo. No ETE seriado (136±233 dias), houve desaparecimento do trombo em dois casos e redução do trombo nos outros dois, após tratamento. O gradiente médio reduziu para 6,2±3 mmHg (p=0,004; IC 95 por cento), e a área valvar aumentou para 2,07±0,4 (p=ns). CONCLUSAO: O ETE mostrou-se útil na detecção de trombo em prótese biológica mitral e eficaz na monitoração do tratamento, em todos casos.


Subject(s)
Humans , Male , Female , Middle Aged , Bioprosthesis , Echocardiography, Transesophageal , Heart Valve Prosthesis , Mitral Valve Insufficiency , Thrombosis , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Insufficiency/surgery , Prosthesis Failure , Postoperative Complications/diagnosis , Retrospective Studies , Thrombosis/surgery
11.
Rev. bras. ecocardiogr ; 16(3): 42-52, jul.-set. 2003. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-394845

ABSTRACT

Objetivo: O Doppler tecidual avalia a velocidade de movimentação das paredes ventriculares e vem sendo empregado no discernimento de alguns padrões de disfunção diastólica. Seu papel na avaliação de pacientes (pac) com padrão normal ou "normalizado" do fluxo de enchimento do ventrículo esquerdo (VE) foi o objetivo deste estudo. Material e métodos: Incluiu-se de forma prospectiva ...


Subject(s)
Humans , Male , Female , Middle Aged , Echocardiography, Doppler/methods , Diastole , Ventricular Dysfunction, Left
12.
REBLAMPA Rev. bras. latinoam. marcapasso arritmia ; 15(1): 41-51, jan.-mar. 2002. ilus
Article in Portuguese | LILACS | ID: lil-316563

ABSTRACT

Paciente do sexo feminino, com 58 anos, portadora de cardiomiopatia dilatada, acompanhada desde 1984 por apresentar insuficiência cardíaca e hipertensão arterial. Na evolução, apresentou bloqueio de ramo esquerdo e fibrilação atrial. No final de 1999, mesmo com a medicação adequada e otimizada para insuficiência cardíaca, apresentava-se em grau funcional IV e as internações hospitalares haviam se tornando cada vez mais freqüentes. Em janeiro de 2000, optou-se pela ablação do nó atrioventricular e pelo implante de um marcapasso endocárdico bifocal multissítio em ventrículo direito. Desde então vem evoluindo bem, com menor número de medicamentos e raras internações


Subject(s)
Humans , Female , Aged , Heart Failure/surgery , Heart Failure/pathology , Pacemaker, Artificial , Echocardiography , Atrial Fibrillation/surgery , Atrial Fibrillation/pathology , Diagnostic Techniques, Cardiovascular
13.
Arq. bras. cardiol ; 73(5): 435-40, Nov. 1999. ilus
Article in English, Portuguese | LILACS | ID: lil-261165

ABSTRACT

This is the report of a five-month-old child presenting clinical evidence of Pompe's disease: severe hypotonicity, hyporeflexia and congestive heart failure. The ECG showed a short PR interval, the chest radiography disclosed marked cardiomegaly, and the echocardiogram revealed marked left ventricular hypertrophy - the most typical finding of this disease. A skeletal muscle biopsy led to final diagnosis, because in the histopathologic study marked increased glycogen accumulation was evident. Death occurred two months after symptom onset.


Subject(s)
Humans , Female , Infant , Glycogen Storage Disease Type II/diagnosis , Echocardiography , Electrocardiography , Glycogen Storage Disease Type II/pathology
15.
Arq. bras. cardiol ; 62(6): 431-433, jun. 1994. ilus
Article in Portuguese | LILACS | ID: lil-159863

ABSTRACT

We present three patients with left ventricular free wall rupture post acute myocardial infarction, all three treated successfully through surgery. Two of them were submitted to streptokinase IV. In all cases the diagnosis were based on clinical and echocardiographic features. The authors conclude that the diagnostic suspicion can be done easily, the echocardiogram is very useful, and the surgical treatment may led to a good short- and long-term survival


Subject(s)
Humans , Male , Female , Middle Aged , Myocardial Infarction/surgery , Heart Rupture, Post-Infarction/surgery , Echocardiography, Doppler , Follow-Up Studies , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Heart Rupture, Post-Infarction/complications , Heart Rupture, Post-Infarction/diagnosis
16.
Arq. bras. cardiol ; 60(3): 157-163, mar. 1993. ilus, tab
Article in Portuguese | LILACS | ID: lil-126174

ABSTRACT

Objetivo - Analisar a utilidade do ecocardiograma (ECO) no diagnóstico e no acompanhamento de pacientes com embolia pulmonar maciça (EP), submetidos à terapêutica fibrinolítica ou cirúrgica. Métodos - Foram incluídos retrospectivamente sete pacientes (cinco homens), com idade média de 37 ñ 19 anos, portadores de EP confirmada à angiografia. Seis foram submetidos à terapêutica fibrinolítica com estreptoquinase IV (EQ) e um à cirurgia. O diagnóstico definitivo de EP ao ECO foi a detecçäo de trombos no leito arterial pulmonar. Foram estudados: diâmetro diastólico ventricular direito (DDVD), movimento do septo interventricular (SIV), tempo de aceleraçäo sistólico (TAC) e pressäo sistólica pulmonar (PSP). Resultados - O ECO identificou trombos em cinco dos sete pacientes (71//), principalmente quando localizados em artéria pulmonar direita (quatro casos (80//. Esse método foi ainda eficaz na identificaçäo de um dos cinco casos (20//) com trombose de ramos lobar direito e um de dois casos com comprometimento da artéria pulmonar esquerda (50//), sendo incapaz de localizar trombos em ramos lobares esquerdos (seis pacientes). Quatro dos cinco pacientes com trombos pulmonares ao ECO receberam EQ,, e um cirurgia. O ECO seriado mostrou dissoluçäo dos trombos em três daqueles com EQ e no caso com tratamento cirúrgico. O ECO inicial mostrou DDVD aumentado em 5/7 pacientes, movimento anômalo do SIV em 5/7 pacientes e TAC inferior a 100ms em todos os casos. A PSP foi 64,4 ñ 22,8mmHg ao ECO, versus 75,4 ñ 24,03mmHg à angiografia (r=0,78; p=0,11). Houve diminuiçäo do DDVD (30 ñ 5,02 para 23 ñ 2,2; p = 0,04) e aumento do TAC (50 ñ 10,8 para 106,67 ñ 16 ms; p < 0,001) no estudo seriado. Conclusäo - O ECO é um importante instrumento no diagnóstico de EP, fornecendo dados referentes à hemodinâmica pulmonar, à localizaçäo dos trombos e à evoluçäo terapêutica do paciente


Purpose - The aim of the study was to analyse the role of 2D echocardiogram (ECHO) in the diagnosis of massive pulmonary embolism (PE), and in the follow-up after fibrinolytic or surgical treatment. Methods - Echocardiographic studies were retrospectively analysed in seven patients, 5 male, meanage 37±19 years, with massive pulmonary embolism (PE) confirmed by pulmonary angiography. Six of them were submitted to fibrinolytic theraphy with IV streptokinase (SK), and one underwent surgery. The diagnosis of PE by ECHO was made by the detection of thrombi in the pulmonary vascular bed. ECHO measurements included the right ventricular diastolic diameter (RVDD), interventricular septal motion (IVS), acceleration time (AcT), and peak pulmonary artery pressure (PAP). Results - The ECHO study diagnosed thrombi in five out of seven patients (71%), mainly if they were present in the right main pulmonary artery (four cases - 80%). It was also able to locate one out of five patients with thrombus in the right lobar artery and one out of two patients in the left main pulmonary artery; it was unable to identify six patients with involvement of the left lobar arteries. Four out of five patients with PE, diagnosed by ECHO, were submitted to fibrinolytic therapy, and one underwent surgery. The follow-up study showed dissolution of the thrombus in three of those with SK and in the one with surgical treatment. The initial ECHO study showedf ve out of 7 patients with increased RVDD, 5/7 patients with abnormal IVS motion, and all of them with decreased AcT (64 ± 16 ms). The PSP was 64.4 ± 22.8 mmHg by ECHO, versus 75.4 ± 24,03 mmHg by angiography (r = 0.78; p = 0.11). There was a reduction of the RVDD (30 ± 5.02 to 23 ± 2.2) and an increased of the AcT (50 ± 10.8 to 106,67 ± 16) at the serial examination. Conclusion - The ECHO study is an important tool for the diagnosis of PE, informing about pulmonary pressure, presence and position of thrombus, and treatment results


Subject(s)
Humans , Male , Female , Pulmonary Embolism , Echocardiography , Pulmonary Embolism/surgery , Pulmonary Embolism/drug therapy , Streptokinase/therapeutic use , Angiography , Predictive Value of Tests , Retrospective Studies , Follow-Up Studies , Regression Analysis , Ventricular Function, Right , Hypertension, Pulmonary , Stroke Volume
17.
Arq. bras. cardiol ; 51(5): 377-380, nov. 1988. tab
Article in Portuguese | LILACS, SES-SP | ID: lil-65409

ABSTRACT

Estudamos 24 pacientes portadores de estenose tricúspide (ET) associada à estenose mitral submetidos ao tratamento cirúrgico entre 1981 a 1986. Grupo I-16 (66%) pacientes com diagnóstico pré-operatório (clínico e/ou ecocardiográfico e/ou hemodinâmico), oito (50%) com insuficiência tricúspide (IT) associada, idade média de 32 anos, todos em classe funcional (CF, NYHA) III/IV, 12 (72%) com predomínio de insuficiência cardíaca direta (ICD). Foi realizada comissurotomia tricúspide em 13 (81%) pacientes, em três associada à plástica de De Vega. Em três pacientes procedeu-se a implante de prótese em posiçäo tricúspide (IVT). Os três pacientes sobmetidos a IVT faleceram. Doze (75%) pacientes receberam alta hospitalar CF/II e em período médio de 28 meses, dois (16%) apresentavam-se em CF III e os demais em CFI/II. Grupo II - oito (33%) pacientes cujo diagnóstico de ET foi apenas trans-operatório, todosIT associada, idade média de 31 anos, todos em CF III/IV, sete (87%) com predomínio de ICD. Na evoluçäo pós-operatória imediata, todos tiveram alta hospitalar em CFI/II. Em período pós-operatório tardio, houve um óbito, de causa desconhecida. Em conclusäo, a ET näo reconhecida do ponto de vista clínico pode ser perfeitamente identificada no ato operatório e deve ser uma possibilidade a ser pesquisada pelo cirurgiäo mesmo em caso admitidos com IT funcional no pré-operatório. Outrossim, a IT deve ser considerada como fator relevante de näo reconhecimento da ET


Subject(s)
Humans , Male , Female , Tricuspid Valve Insufficiency/surgery , Intraoperative Care , Tricuspid Valve Stenosis/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL