Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
2.
Chinese Medical Journal ; (24): 649-654, 2011.
Article in English | WPRIM | ID: wpr-321444

ABSTRACT

<p><b>BACKGROUND</b>The status of sensitization in kidney transplant recipients in the last 10 years and the trend of induction and maintenance therapy in patients of different panel-reactive antibody (PRA) levels have not been analyzed. The aim of this study was to investigate the current status of pre-transplant sensitization and its association with graft outcome.</p><p><b>METHODS</b>A total of 155 570 kidney transplants reported to United Network for Organ Sharing (UNOS) during 2000 - 2009 were included in this study. We investigated the current status of pre-transplant sensitization and its association with graft outcome, and also compared the usage trend of 16 induction agents and 7 maintenance immunosuppressants in patients at different PRA levels. The difference of distributions of categorical variables between groups was investigated using the chi-square test. Unpaired t test or one-way analysis of variance (ANOVA) were used for numerical variables. The survival rates of transplant recipients were estimated using Kaplan-Meier methods and significance was determined by Log-rank test. Two-side P value < 0.05 was considered statistically significant. All statistical analyses were performed using STATA 10 with all available updates as of March 2010 (StataCorp LP, College Station, Texas 77845, USA).</p><p><b>RESULTS</b>Despite the fact of the decreased percentages of kidney transplant recipients with presensitization history, the mean PRA levels of all kidney recipients has been increasing in the last 7 years, which was possibly due to the introduction of more sensitive antibody testing techniques. The percentage of patients with treated rejection episodes within one year post-transplant were significantly higher in sensitized patients (PRA = 50% - 100%:14.3% and PRA = 1% - 49%:13.9%) than in non-sensitized patients (12.4%). Both 1- and 5-year graft survival rates improved in the last 10 years; this was more significant in high PRA patients. Thymoglobulin was the most commonly used induction agent in last 10 years. Its users increased from 10% to 46% in non-sensitized patients, from 12% to 57% in PRA 1% - 49% patients, and from 19% to 63% in PRA 50% - 100% patients. The users of Campath, intravenous immunoglobulin (IVIG), and Rituximab have been increasing and reached 16%, 20%, and 11% in highly sensitized patients. In the last 5 years, steroid-free patients were 33% - 36%, 30% - 37%, and 10% - 25% for PRA 0, 1% - 49%, and 50% - 100% respectively. Almost 90% of patients were on Prograf at discharge. It seems that Myfortic users have been increasing since 2005 and it may soon replace mycophenolate mofetil (MMF) if long-term follow-up study conforms its safety and efficacy.</p><p><b>CONCLUSIONS</b>Application of sensitive antibody testing techniques increased the mean PRA levels of transplant recipients in spite of a decreased percentage of sensitized recipients. Induction and maintenance therapy differed in patients at different PRA levels.</p>


Subject(s)
Humans , Graft Rejection , Allergy and Immunology , Graft Survival , Allergy and Immunology , Immunosuppression Therapy , Methods , Immunosuppressive Agents , Therapeutic Uses , Kidney Transplantation , Allergy and Immunology
3.
Chinese Medical Journal ; (24): 771-774, 2011.
Article in English | WPRIM | ID: wpr-321422

ABSTRACT

<p><b>OBJECTIVE</b>To review this efficacy and safety of bortezomib, a proteasome inhibitor, in the setting of the sensitized transplant candidate.</p><p><b>DATA SOURCES</b>The data used in this review were from articles published (PubMed) between 2000 to 2010. Additionally abstracts from medical meetings related to transplant were also used.</p><p><b>STUDY SELECTION</b>Articles were selected if they were trial results or case studies for the use of bortezomib in the sensitized patient population.</p><p><b>RESULTS</b>The early data using bortezomib as a part of desensitization regimens has shown success. Although one cycle (4 doses) of bortezomib seems to have affect on many patients, it also seems likely that to provide complete desensitization multiple cycles will be required. Regarding safety, bortezomib has been shown to have minimal side effects. The most common side effects reported are those of thrombocytopenia and anemia. These side effects are dose related and self limiting upon discontinuation of the treatment.</p><p><b>CONCLUSIONS</b>Bortezomib with plasmapheresis is a promising new alternative to desensitization protocols that use either high dose intravenous immune globulin (IVIG) or low dose IVIG and plasmapheresis. The efficacy on antibody reduction looks to be batter that that of the IVIG based regimens without significant addition toxicity. The results of ongoing prospective trials are positive and their complete results are greatly anticipated.</p>


Subject(s)
Humans , Boronic Acids , Therapeutic Uses , Bortezomib , Graft Rejection , Allergy and Immunology , Protease Inhibitors , Therapeutic Uses , Proteasome Endopeptidase Complex , Metabolism , Pyrazines , Therapeutic Uses , Transplants
4.
Journal of Korean Medical Science ; : 461-467, 2005.
Article in English | WPRIM | ID: wpr-53826

ABSTRACT

We detected pregnancy related new molecule, human chorionic gonadotropin related protein (hCGRP) in the urine of a pregnant women by using a monoclonal antibody against the human chorionic gonadotropin (hCG). This study examined the effectiveness of urinary hCGRP quantification in diagnosing ectopic pregnancy. This study included 40 normal pregnant women and 25 patients with ectopic pregnancy. Patients' serum and urinary intact whole hCG (i-hCG) and hCGRP concentrations were measured using sandwich ELISA and the ratio of hCGRP to i-hCG was calculated. Statistical analysis was performed using statistical package for social sciences (SPSS) 10.0. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the cut-off value to discriminate ectopic pregnancies from normal intrauterine pregnancies. Urinary hCGRP and hCGRP/i-hCG ratio in ectopic pregnancy group (14 +/- 6.6 ng/mL, 4.6 +/- 1.9%, respectively) were significantly lower than those of normal pregnancy group (149 +/- 10.2 ng/mL, 29.7 +/- 1.9%, respectively; p<0.001). Based on ROC curve analysis, a cut-off point of urinary hCGRP/i-hCG ratio <16.2% discriminated between ectopic pregnancy and normal pregnancy with a sensitivity, specificity, positive predictive value and negative predictive value of 92.0%, 90.0%, 32.6%, and 99.5%, respectively. Urinary hCGRP/i-hCG ratio measurement may be effective in diagnosing ectopic pregnancy.


Subject(s)
Adult , Female , Humans , Pregnancy , Antibodies, Monoclonal/immunology , Chorionic Gonadotropin , Enzyme-Linked Immunosorbent Assay/methods , Pregnancy, Ectopic/diagnosis , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL