Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Year range
1.
Int. j. odontostomatol. (Print) ; 13(2): 162-171, jun. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1002300

ABSTRACT

RESUMEN: Evaluar el proceso de reparación alveolar en ratas sometidas a cirugía de simulacro u ovariectomizadas tras el relleno alveolar con coágulo o con biosilicato cristalino. Sesenta ratas Wistar fueron divididas en cuatro grupos (n=15) de acuerdo con el tratamiento: Grupo 1- ratas sometidas a cirugía de simulacro con alveolos rellenados con coágulo; Grupo 2- ratas sometidas a cirugía de simulacro con alveolos rellenados con biosilicato cristalino; Grupo 3- ratas ovariectomizadas con alveolos rellenados con coágulo; Grupo 4- ratas ovariectomizadas con alveolos rellenados con biosilicato cristalino. Después de 7, 14 y 28 días, los animales fueron sacrificados, se tomaron muestras óseas que fueron teñidas con hematoxilina-eosina y analizadas al microscopio para realizar un análisis histomorfométricos. Los mayores porcentajes de formación de hueso se presentaron en los grupos 1 (32 % a los 7 días, 46 % a los 14 días y 83.5 % a los 28 días) y 4 (27,1 % a los 7 días, 41,1 % a los 14 días y 79,7 % a los 28 días). En los alveolos rellenados con coágulo, las ratas sometidas a cirugía de simulacro mostraron los mejores resultados, mientras que, en los alveolos rellenados con biosilicato, las ratas ovariectomizadas tenían porcentajes significativamente mayores. En este estudio, el biosilicato cristalino se comportó como un biomaterial adecuado para la reparación ósea, favoreciendo la osteoconducción.


ABSTRACT: The objective of this study was to assess the process of alveolar bone repair in rats subjected to sham surgery or ovariectomized rats, after alveolar filling with clot or with crystalline biosilicate. Sixty Wistar rats were divided into four groups (n = 15) according to the treatment: Group 1 - rats subjected to sham surgery with sockets filled with clot; Group 2- rats submitted to sham surgery with sockets filled with crystalline biosilicate; Group 3 ovariectomized rats with sockets filled with clot; Group 4 ovariectomized rats with sockets filled with crystalline biosilicate. After 7, 14 and 28 days, the animals were sacrificed, bone samples were taken, stained with hematoxylin-eosin and analyzed under a microscope to perform a histomorphometric analysis. The highest percentages of bone formation were presented in groups 1 (32 % at 7 days, 46 % at 14 days and 83.5 % at 28 days) and 4 (27.1 % at 7 days, 41.1 % at 14 days and 79.7 % after 28 days). In the sockets filled with clot, the rats subjected to sham surgery showed the best results, while in the sockets filled with biosilicate, the ovariectomized rats had significantly higher percentages. In this study, the crystalline biosilicate behaved as an adequate biomaterial for bone repair, favoring osteoconduction.


Subject(s)
Animals , Rats , Bone and Bones/cytology , Ceramics , Bone Substitutes , Alveolar Ridge Augmentation , Bone Regeneration , Brazil , Ovariectomy , Rats, Wistar , Silicates , Animal Experimentation
2.
Braz. dent. j ; 28(4): 489-497, July-Aug. 2017. tab, graf
Article in English | LILACS | ID: biblio-888668

ABSTRACT

Abstract This study evaluated the effect of a bioactive glass ceramic for the control of erosion and caries lesions. Fragments (n=10) of bovine enamel and root dentin received daily application of different treatments (Biosilicate; Acidulated Phosphate Fluoride- APF; Untreated - control) during the performance of erosive cycles. Surfaces were analyzed with 3D optical profilometry to quantify the superficial loss in four periods (1, 7, 14 and 21 days), as well as the lesion depth with confocal laser scanning microscopy. For caries progression assessment, initial Knoop microhardness was measured on enamel bovine fragments. Initial carious lesions were developed and specimens were divided into three groups (n=10), according to the daily topical application (Biosilicate; APF; no application - control), during the de-remineralization cycles for 14 days. Final microhardness was obtained to calculate the change of surface microhardness. Subsurface demineralization was analyzed using cross-sectional microhardness (depths 10, 30, 50, 70, 90, 110 and 220 µm). Data were tested using ANOVA and Tukey's test (a=5%). Results of erosive evaluation showed that Biosilicate promoted the lowest (p<0.05) values of surface loss, regardless of time, for both enamel and dentin; APF promoted lower (p<0.05) surface loss than control; analyzing different periods of time, APF did not show difference (p>0.05) between 14 and 21 days of demineralization. Results of enamel caries assessment showed that Biosilicate resulted in higher (p<0.05) surface and subsurface microhardness than both APF and control-applications. It may be concluded that Biosilicate application showed a higher potential to reduce surface loss and development of erosion and caries lesions.


Resumo Este estudo avaliou o efeito de uma vitrocerâmica bioativa para o controle de lesões de erosão e cárie. Fragmentos (n=10) de esmalte bovino e dentina radicular receberam aplicação diária de diferentes tratamentos (Biosilicato; Fluoreto de Fosfato Acidulado - APF; não tratado - controle) durante a realização de ciclos erosivos. As superfícies foram analisadas com profilometria óptica 3D para quantificar a perda superficial em quatro períodos (1, 7, 14 e 21 dias), bem como a profundidade da lesão com microscopia confocal de varredura a laser. Para a avaliação da progressão de cárie, foi obtida a microdureza Knoop inicial de fragmentos de esmalte bovino. As lesões cariosas iniciais foram desenvolvidas e os espécimes foram divididos em três grupos (n =10), de acordo com a aplicação tópica diária (Biosilicato; APF; sem aplicação - controle) durante os ciclos de desmineralização por 14 dias. A microdureza final foi obtida para calcular a perda da microdureza superficial. A desmineralização sub-superficial foi analisada utilizando microdureza transversal (profundidades 10, 30, 50, 70, 90, 110 e 220 μm). Os dados foram testados utilizando ANOVA e teste de Tukey (α=5%). Os resultados da avaliação erosiva mostraram que o Biosilicato promoveu os menores valores (p <0,05) de perda superficial, independente do tempo, tanto para o esmalte como para a dentina; APF promoveu menor (p <0,05) perda de superfície do que controle; analisando os períodos de tempo, APF não mostrou diferença (p>0,05) entre 14 e 21 dias de desmineralização. Os resultados da avaliação da cárie no esmalte mostraram que o Biosilicato resultou em maiores (p<0,05) valores de microdureza superficial e subsuperficial do que as aplicações APF e controle. Pode-se concluir que a aplicação de Biosilicato apresentou maior potencial de redução da perda superficial e desenvolvimento de lesões de erosão e cárie.


Subject(s)
Animals , Cattle , Acidulated Phosphate Fluoride , Ceramics , Dentin/pathology , Glass , Tooth Erosion/prevention & control , Dental Caries/prevention & control , Hardness Tests , Microscopy, Confocal , Microscopy, Electron, Scanning , X-Ray Diffraction
3.
Rev. bras. oftalmol ; 72(1): 21-25, jan.-fev. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-667592

ABSTRACT

OBJETIVO: Avaliar experimentalmente a biocompatibilidade de cones de biovidro e biovitrocerâmico em cavidades evisceradas de coelhos. MÉTODOS: Foram utilizados 45 coelhos albinos submetidos à cirurgia de evisceração do olho direito, seguida da inclusão de cones de biovidro e dois tipos de biovitrocerâmicos (chamados de FI e FII) na cavidade escleral. Os animais foram sacrificados em três momentos (7, 90 e 180 dias). Os parâmetros avaliados foram: peso, exame clínico diário, exames bioquímicos, avaliação histológica, exame morfométrico. RESULTADOS: Os animais mantiveram-se saudáveis durante o experimento, não tendo ocorrido extrusão do implante em nenhum animal. O exame morfológico mostrou que houve a formação de pseudocápsula ao redor dos cones, com superioridade dos cones de biovidro e biovitrocerâmico FI, os quais apresentaram menor reação inflamatória e menor formação da pseudocápsula ao redor dos cones que os demais. A reação inflamatória foi mais intensa após 7 dias da colocação dos cones, diminuindo em direção aos 180 dias, sendo menos intensa nos coelhos que receberam cones de biovidro. CONCLUSÃO: Os cones de biovidro e biovitrocerâmico FI e FII podem ser úteis para a reparação da cavidade anoftálmica, com melhor resposta quando se usa cones de biovidro e de biovitrocerâmico FI.


OBJECTIVE: To evaluate bioglass, bioglassceramic biocompatibility in rabbit's eviscerated cavities. METHODS: Forty- five rabbits were submitted to right eye evisceration, followed by the inclusion of bioglass and bioglassceramic I e II prosthesis in the escleral cavity. The animals were sacrificed at seven, 90 and 180 days after surgery. The animals had daily clinical exam; biochemical exam, histological analysis and morphometric evaluation. RESULTS: The animals stayed healthy during the expriment, with good cone integration to the host tissue. None cone extrusion were observed. Histologically, it was observed pseudocapsule formation around the cones and the inflammatory reaction was higher at M1, getting progressively lower while getting at M3, being the lowest in rabbits which received bioglass cones (GA) than at any other groups. CONCLUSION: Bioglass and bioglassceramic I e II cones can be useful to repair anophthalmic cavity.


Subject(s)
Animals , Rabbits , Biocompatible Materials , Eye Evisceration , Glass , Implants, Experimental , Materials Testing/veterinary , Clinical Trial
4.
Braz. oral res ; 24(4): 381-387, Oct.-Dec. 2010. ilus, tab
Article in English | LILACS | ID: lil-569231

ABSTRACT

Dentin hypersensitivity (DH) is a painful response to stimulus applied to the open dentinal tubules of a vital tooth. It's a common oral condition, however, without an ideal treatment available yet. This work evaluated in vitro the effect of micron-sized particles from a novel bioactive glass-ceramic (Biosilicate) in occluding open dentinal tubules. A dentin disc model was employed to observe comparatively, using scanning electron microscopy (SEM), dentinal tubule occlusion by different products and deposition of hydroxyl carbonate apatite (HCA) on dentin surface by Biosilicate, after a single application: G1 - Dentifrice with potassium nitrate and fluoride; G2 - Two-step calcium phosphate precipitation treatment; G3 - Water-free gel containing Biosilicate particles (1 percent); G4 - Biosilicate particles mixed with distilled water in a 1:10 ratio; all of them after 1, 12 and 24 hours of immersion in artificial saliva. Fourier transform infrared spectroscopy (FTIR) was performed to detect HCA formation on dentin discs filled with Biosilicate after 2 minutes, 30 minutes and 12 hours of immersion in artificial saliva. SEM showed a layer of HCA formed on dentin surface after 24 hours by G4. G1, G2 and G3 promoted not total occlusion of open dentinal tubules after 24 hours. FTIR showed HCA precipitation on the dentin surface induced by Biosilicate after 30 minutes. The micron-sized particles from the bioactive glass-ceramic thus were able to induce HCA deposition in open dentinal tubules in vitro. This finding suggests that Biosilicate may provide a new option for treating DH.


Subject(s)
Ceramics/pharmacology , Dentin Desensitizing Agents/pharmacology , Dentin Sensitivity/drug therapy , Dentin/drug effects , Dentin Desensitizing Agents/therapeutic use , Dentin/chemistry , Dentin/ultrastructure , Microscopy, Electron, Scanning , Saliva, Artificial , Spectroscopy, Fourier Transform Infrared , Surface Properties , Time Factors
5.
Braz. dent. j ; 21(5): 383-389, 2010. ilus, tab
Article in English | LILACS | ID: lil-568980

ABSTRACT

The aim of this study was to investigate the histological and histomorphometrical bone response to three Biosilicates with different crystal phases comparing them to Bioglass®45S5 implants used as control. Ceramic glass Biosilicate and Bioglass®45S5 implants were bilaterally inserted in rabbit femurs and harvested after 8 and 12 weeks. Histological examination did not revealed persistent inflammation or foreign body reaction at implantation sites. Bone and a layer of soft tissue were observed in close contact with the implant surfaces in the medullary canal. The connective tissue presented few elongated cells and collagen fibers located parallel to implant surface. Cortical portion after 8 weeks was the only area that demonstrated significant difference between all tested materials, with Biosilicate 1F and Biosilicate 2F presenting higher bone formation than Bioglass®45S5 and Biosilicate® vitreo (p=0.02). All other areas and periods were statistically non-significant (p>0.05). In conclusion, all tested materials were considered biocompatible, demonstrating surface bone formation and a satisfactory behavior at biological environment.


O objetivo deste estudo foi investigar histologicamente e histomorfometricamente a resposta óssea a três diferentes fases cristalinas do Biosilicato®, comparando-os aos implantes de Bioglass®45S5 utilizados como controles. Implantes de cerâmicas de Biosilicato® e implantes de Bioglass®45S5 foram inseridos bilateralmente em fêmures de coelho e avaliações histológicas realizadas após 8 e 12 semanas. As avaliações histológicas não revelaram inflamação persistente ou reação de corpo estranho nos sítios de implantação dos biovidros. A formação de tecido ósseo pôde ser observada em maior quantidade na porção cortical, com tecido conjuntivo sendo observado em íntimo contato com as superfícies dos implantes apenas na porção medular. O tecido conjuntivo apresentou células com forma alongada e fibras de colágeno localizado paralelamente à superfície do implante. A porção cortical (após 8 semanas) foi a única área que demonstrou diferença significante entre os materiais estudados, com o Biosilicato 1F e o Biosilicato 2F demonstrando maior formação de tecido ósseo em contato com a superfície quando compardos aos implantes de Bioglass®45S5 e Biosilicato®vítreo (p=0,02). As outras áreas estudadas nos diferentes períodos não foram consideradas estatisticamente significantes (p>0,05). Pode-se concluir que todos os materiais testados foram considerados biocompatíveis, com formação óssea na superfície e comportamento em ambiente biológico satisfatório.


Subject(s)
Animals , Male , Rabbits , Biocompatible Materials/chemistry , Bone Substitutes/chemistry , Femur/pathology , Silicates/chemistry , Bone Marrow/pathology , Collagen , Crystallography , Ceramics/chemistry , Connective Tissue/pathology , Materials Testing , Osseointegration/physiology , Osteogenesis/physiology , Surface Properties , Time Factors
6.
Braz. j. otorhinolaryngol. (Impr.) ; 75(5): 665-668, Sept.-Oct. 2009. ilus
Article in English, Portuguese | LILACS | ID: lil-530088

ABSTRACT

Changes, destructions and interruptions in middle ear ossicular chain architecture may be caused by infection, trauma, tumors, congenital alterations or prior surgeries. Nonetheless, infectious and inflammatory processes, focal or generalized which affect the middle ear are the most prevalent, causing a great demand for ossiculoplasty. Biosilicato® is a new material which can be used in the middle ear with the goal of reconstructing the ossicular chain. It is a bioactive type A vitroceramic, in other words, it binds to bone or soft tissue in a matter of a few hours, thanks to the formation of hydroxy-carbonateapatatie in its contact surface when in contact with body fluids. AIMS: The goal of the present paper is to assess biosilicate ototoxicity and vestibular toxicity in experimental animals, for later use in humans. MATERIALS AND METHODS: This a clinical and experimental study in which otoacoustic emissions were performed before and after the placement of Biosilicate in the middle ear of experimental animals and a scanning electron microscopy was carried out in the cochlea, saccule, utriculus and macula of the semicircular canals after 30 and 90 days to assess oto and vestibular toxicity. RESULTS: There were no signs of oto or vestibular toxicity in any of the groups associated with biosilicate. CONCLUSION: Biosilicate is a safe material to be used in ossiculoplasties


As alterações, destruições e interrupções da arquitetura da cadeia ossicular da orelha média podem ser causadas por infecções, trauma, tumores, alterações congênitas ou cirurgias prévias. Entretanto os processos inflamatórios e infecciosos, focais ou generalizados que acometem a orelha média são os mais prevalentes, gerando uma enorme demanda de ossiculoplastias. O Biosilicato® é um novo material que pode ser usado em orelhas médias com o objetivo de reconstruir a cadeia ossicular. Constitui-se de uma vitrocerâmica bioativa do tipo A, ou seja, que se liga a tecido ósseo ou a tecido mole em algumas horas, devido à formação de hidroxicarbonatoapatita em sua superfície de contato quando em contato com fluidos corpóreos. OBJETIVO: O objetivo deste trabalho é avaliar a ototoxicidade e vestibulotoxicidade do Biosilicato em cobaias, para posterior utilização em humanos. MATERIAL E MÉTODO: Trata-se de um estudo clínico e experimental, onde foram realizadas emissões otoacústicas antes e após a colocação de Biosilicato na orelha média de cobaias e realizada microscopia eletrônica de varredura da cóclea, sáculo, utrículo e máculas dos canais semicirculares após 30 e 90 dias para avaliar a oto e vestibulotoxicidade. RESULTADOS: Não houve sinais de oto ou vestibulotoxicidade em nenhum dos grupos relacionados ao Biosilicato. CONCLUSÃO: O Biosilicato é um material seguro para ser usado em ossiculoplastias.


Subject(s)
Animals , Guinea Pigs , Male , Biocompatible Materials/toxicity , Ceramics/toxicity , Ear, Inner/drug effects , Silicates/toxicity , Drug Evaluation, Preclinical , Ear, Inner/ultrastructure , Microscopy, Electron, Scanning , Ossicular Prosthesis , Ossicular Replacement , Otoacoustic Emissions, Spontaneous/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL